DNA probes

DNA 探针
  • 文章类型: Journal Article
    The 2013/2014 American Society of Clinical Oncology and College of American Pathologists (ASCO-CAP) guidelines for HER2 testing by fluorescence in situ hybridization (FISH) designated an \"equivocal\" category (average HER2 copies per tumor cell ≥4-6 with HER2/CEP17 ratio <2.0) to be resolved as negative or positive by assessments with alternative control probes. Approximately 4% to 12% of all invasive breast cancers are characterized as HER2-equivocal based on FISH.
    To evaluate the following hypotheses: (1) genetic loci used as alternative controls are heterozygously deleted in a substantial proportion of breast cancers; (2) use of these loci for assessment of HER2 by FISH leads to false-positive assessments; and (3) these HER2 false-positive breast cancer patients have outcomes that do not differ from clinical outcomes for patients with HER2-negative breast cancer.
    We retrospectively assessed the use of chromosome 17 p-arm and q-arm alternative control genomic sites (TP53, D17S122, SMS, RARA, TOP2A), as recommended by the 2013/2014 ASCO-CAP guidelines for HER2 testing, in patients whose data were available through Molecular Taxonomy of Breast Cancer International Consortium (METABRIC) and whose tissues were available through the Breast Cancer International Research Group clinical trials. We used data from an international cohort database of invasive breast cancers (1980 participants) and international clinical trial of adjuvant chemotherapy in invasive, node-positive breast cancer patients.
    The primary objectives were to (1) assess frequency of heterozygous deletions in chromosome 17 genomic sites used as FISH internal controls for evaluation of HER2 status among HER2-equivocal cancers; (2) characterize impact of using deleted sites for determination of HER2-to-internal-control-gene ratios; (3) assess HER2 protein expression in each subgroup; and (4) compare clinical outcomes for each subgroup.
    Of the 1980 patients in METABRIC,1915 patients were fully evaluated. In addition, 100 HER2-equivocal breast cancers by FISH and 100 comparator FISH-negative breast cancers from the BCIRG-005 trial were analyzed. Heterozygous deletions, particularly in specific p-arm sites, were common in both HER2-amplified and HER2-not-amplified breast cancers. Use of alternative control probes from these regions to assess HER2 by FISH in HER2-equivocal as well as HER2-not-amplified breast cancers resulted in high rates of false-positive ratios (HER2-to-alternative control ratio ≥2.0) owing to heterozygous deletions of control p-arm genomic sites used in ratio denominators. Misclassification of HER2 status was observed not only in breast cancers with ASCO-CAP equivocal status but also in breast cancers with an average of fewer than 4.0 HER2 copies per tumor cell when using alternative control probes.
    The indiscriminate use of alternative control probes to calculate HER2 FISH ratios in HER2-equivocal breast cancers may lead to false-positive interpretations of HER2 status resulting from unrecognized heterozygous deletions in 1 or more of these alternative control genomic sites and incorrect HER2 ratio determinations.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    以亚甲基蓝(MB)为嵌入剂,制备了基于氧化锌/铂-钯(ZnO/Pt-Pd)修饰的氟掺杂氧化锡(FTO)玻璃板的电化学基因传感器,用于检测登革热病毒(DENV)的共有DNA序列。为了实现它,将探针DNA(PDNA)固定在ZnO/Pt-Pd纳米复合材料修饰的FTO电极表面。通过高分辨率透射电子显微镜(HRTEM)对合成的纳米复合材料进行了表征,能量色散X射线分析(EDX),原子力显微镜(AFM),扫描电子显微镜(SEM),紫外-可见光谱,X射线衍射(XRD)分析和傅里叶变换红外(FTIR)光谱。该PDNA修饰电极(PDNA/ZnO/Pt-Pd/FTO)用作检测靶杂交DNA(TDNA)的信号放大平台。通过降低电流检测PDNA和TDNA之间的杂交,由阴离子介质的相互作用产生,即,亚甲基蓝(MB)与ssDNA的游离鸟嘌呤(3'G)。传感器的动态线性范围为1×10-6M至100×10-6M,LOD为4.3×10-5M,LOQ为9.5×10-5M。已经开发了用于登革热检测的主要血清型特异性生物传感器。此处报道的基因传感器消除了血清型特异性DNA传感器的情况下错误结果的可能性。这是其中存在于登革热病毒的所有血清型中的保守序列已用于制造基因传感器的报道。
    An electrochemical genosensor based on Zinc oxide/platinum-palladium (ZnO/Pt-Pd) modified fluorine doped tin oxide (FTO) glass plate was fabricated for detection of consensus DNA sequence of Dengue virus (DENV) using methylene blue (MB) as an intercalating agent. To achieve it, probe DNA (PDNA) was immobilized on the surface of ZnO/Pt-Pd nanocomposites modified FTO electrode. The synthesized nano-composites were characterized by high resolution transmission electron microscopy (HRTEM), energy dispersive X-ray analysis (EDX), atomic force microscopy (AFM), scanning electron microscopy (SEM), UV-Vis spectroscopy, X-ray diffraction (XRD) analysis and Fourier transform infra-red (FTIR) spectroscopy. This PDNA modified electrode (PDNA/ZnO/Pt-Pd/FTO) served as a signal amplification platform for the detection of the target hybridized DNA (TDNA). The hybridization between PDNA and TDNA was detected by reduction in current, generated by interaction of anionic mediator, i.e., methylene blue (MB) with free guanine (3\'G) of ssDNA. The sensor showed a dynamic linear range of 1 × 10-6M to 100 × 10-6M with LOD as 4.3 × 10-5 M and LOQ as 9.5 × 10-5 M. Till date, majorly serotype specific biosensors for dengue detection have been developed. The genosensor reported here eliminates the possibility of false result as in case of serotype specific DNA sensor. This is the report where conserved sequences present in all the serotypes of Dengue virus has been employed for fabrication of a genosensor.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Real-time RT-PCR (QRT-PCR) is a sensitive method for the detection of minimal disease (MD) and may improve monitoring of disease status and stratification of patients for therapy. Where tumour-specific mRNAs have not been identified, the selection of which target(s) is(are) optimal for the detection of MD remains a challenge. This reflects the heterogeneity of tumour cells, the stability of mRNAs and low-level of transcription in cells of the normal haemopoietic compartments. The aim of this study was to establish for the first time guidelines for the systematic prioritization of potential markers of MD detected by QRT-PCR prior to evaluation in multicentre prospective clinical outcome studies. We combined microarray analysis, ESTs gene expression profiles, improved probe-sets sequence annotation, and previously described standard operating procedures for QRT-PCR analysis to identify and prioritize potential markers of MD. Using this methodology, we identified 49 potential markers of MD in neuroblastoma (NB), of which 11 were associated with neuronal function. We found that, in addition to TH, Phox2B and DCX mRNA may be useful targets for the detection of MD in children with NB. This same strategy could be exploited to select MD markers of other solid tumours from the large number of potential targets identified by microarray gene expression profiles.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Comparative Study
    Monitoring multiple myeloma patients for relapse requires sensitive methods to measure minimal residual disease and to establish a more precise prognosis. The present study aimed to standardize a real-time quantitative polymerase chain reaction (PCR) test for the IgH gene with a JH consensus self-quenched fluorescence reverse primer and a VDJH or DJH allele-specific sense primer (self-quenched PCR). This method was compared with allele-specific real-time quantitative PCR test for the IgH gene using a TaqMan probe and a JH consensus primer (TaqMan PCR). We studied nine multiple myeloma patients from the Spanish group treated with the MM2000 therapeutic protocol. Self-quenched PCR demonstrated sensitivity of >or=10(-4) or 16 genomes in most cases, efficiency was 1.71 to 2.14, and intra-assay and interassay reproducibilities were 1.18 and 0.75%, respectively. Sensitivity, efficiency, and residual disease detection were similar with both PCR methods. TaqMan PCR failed in one case because of a mutation in the JH primer binding site, and self-quenched PCR worked well in this case. In conclusion, self-quenched PCR is a sensitive and reproducible method for quantifying residual disease in multiple myeloma patients; it yields similar results to TaqMan PCR and may be more effective than the latter when somatic mutations are present in the JH intronic primer binding site.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Evaluation Study
    In biology experiments, oligonucleotide microarrays are contacted with a solution of long nucleic acid targets. The hybridized probes thus carry long tails. When the surface density of the oligonucleotide probes is high enough, the progress of hybridization gives rise to a polyelectrolyte brush due to mutual crowding of the nucleic acid tails. The free-energy penalty associated with the brush modifies both the hybridization isotherms and the rate equations: the attainable hybridization is lowered significantly as is the hybridization rate. When the equilibrium hybridization fraction, x(eq), is low, the hybridization follows a Langmuir type isotherm, x(eq)/(1 - x(eq)) = c(t)K where c(t) is the target concentration and K is the equilibrium constant. K is smaller than its bulk value by a factor (n/N)(2/5) due to wall effects where n and N denote the number of bases in the probe and the target. At higher x(eq), when the brush is formed, the leading correction is x(eq)/(1 - x(eq)) = c(t)K exp - const\'x(eq)(2/3) - x(B)(2/3) where x(B) corresponds to the onset of the brush regime. The denaturation rate constant in the two regimes is identical. However, the hybridization rate constant in the brush regime is lower, the leading correction being exp -const\' x(2/3) - x(B)(2/3).
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Evaluation Study
    Several approaches for the detection of minimal residual disease (MRD) in childhood acute lymphoblastic leukemia (ALL) have shown the importance of determining the level of MRD precisely. In the present study, we tested a new real-time quantitative polymerase chain reaction (RQ-PCR) strategy with minor groove binder (MGB) technology for immunoglobulin heavy chain gene rearrangements by positioning a MGB probe at the germline JH segments and one of the primers at the downstream introns in combination with an allele-specific oligonucleotide (ASO) primer complementary to the VH-DH or DH-JH junctional region. A MGB probe forms extremely stable duplexes with single-stranded DNA targets, allowing the use of shorter probes for hybridization-based assays. Therefore, it shows positional flexibility. We have designed two novel consensus MGB JH germline probes for analyzing all of the germline rearrangements registered in the V BASE database, and demonstrated that the MRD was detectable with the probes in 17 cases of childhood ALL. The actual copy number for the targets and dynamic changes before and after treatment were almost identical between the JH MGB probe and conventional non-MGB probes in each patient. MGB technology will undoubtedly contribute to MRD-PCR studies of childhood ALL.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    我们使用3'-小沟结合剂(MGB)技术开发了免疫球蛋白重链(IgH)基因的共有荧光标记探针,用于检测B细胞非霍奇金淋巴瘤(B-NHL)中的微小残留病(MRD)。来自59例B-NHL患者的序列数据显示,由于体细胞高突变和可变的VH使用,这表明很难设计普通的非MGB探针。MGB探头,其特点是长度较短,但熔化温度较高,比普通的非MGB探头更适合这种情况。事实上,目前的数据表明,与Donovan等人设计的非MGB探针(23/59,39.0%)相比,MGB探针(34/59,57.6%)可检测到的病例多约20%.MGB技术可用于设计用于检测MRD的IgH基因的共有荧光标记探针。
    We used 3\'-minor groove binder (MGB) technology to develop consensus fluorogenically labeled probes of the immunoglobulin heavy-chain (IgH) gene for detecting minimal residual disease (MRD) in B-cell non-Hodgkin lymphoma (B-NHL). Sequence data from 59 patients with B-NHLs revealed a narrow consensus region as a result of somatic hypermutations and variable VH usage, indicating that it would be difficult to design ordinary non-MGB probes. MGB probes, characterized by shorter length but higher melting temperature, are more suitable for this situation than ordinary non-MGB probes. In fact, the present data indicated that about 20% more cases were detectable with MGB probes (34/59, 57.6%) than with the non-MGB probes (23/59, 39.0%) designed by Donovan et al. MGB technology is useful for the design of consensus fluorogenically labeled probes of the IgH gene for detecting MRD.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Sequence-specific oligonucleotide probes play a crucial role in hybridization techniques including PCR, DNA microarray and RNA interference. Once the entire genome becomes the search space for target genes/genomic sequences, however, cross-hybridization to non-target sequences becomes a problem. Large gene families with significant similarity among family members, such as the P450s, are particularly problematic. Additionally, accurate single nucleotide polymorphism (SNP) detection depends on probes that can distinguish between nearly identical sequences. Conventional oligonucleotide probes that are perfectly matched to target genes/genomic sequences are often unsuitable in such cases. Carefully designed mismatches can be used to decrease cross-hybridization potential, but implementing all possible mismatch probes is impractical. Our study provides guidelines for designing non-perfectly matched DNA probes to target DNA sequences as desired throughout the genome. These guidelines are based on the analysis of hybridization data between perfectly matched and non-perfectly matched DNA sequences (single-point or double-point mutated) calculated in silico. Large changes in hybridization temperature predicted by these guidelines for non-matched oligonucleotides fit independent experimental data very well. Applying the guidelines to find oligonucleotide microarray probes for P450 genes, we confirmed the ability of our point mutation method to differentiate the individual genes in terms of thermodynamic calculations of hybridization and sequence similarity.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    Today, quantitative real-time PCR is the method of choice for rapid and reliable quantification of mRNA transcription. However, for an exact comparison of mRNA transcription in different samples or tissues it is crucial to choose the appropriate reference gene. Recently glyceraldehyde 3-phosphate dehydrogenase and beta-actin have been used for that purpose. However, it has been reported that these genes as well as alternatives, like rRNA genes, are unsuitable references, because their transcription is significantly regulated in various experimental settings and variable in different tissues. Therefore, quantitative real-time PCR was used to determine the mRNA transcription profiles of 13 putative reference genes, comparing their transcription in 16 different tissues and in CCRF-HSB-2 cells stimulated with 12-O-tetradecanoylphorbol-13-acetate and ionomycin. Our results show that \"Classical\" reference genes are indeed unsuitable, whereas the RNA polymerase II gene was the gene with the most constant expression in different tissues and following stimulation in CCRF-HSB-2 cells.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Comparative Study
    在治疗期间的早期时间点对残留白血病细胞的定量可以可靠地预测急性淋巴细胞白血病(ALL)儿童的预后。最近,半定量微小残留病(MRD)检测方法,例如斑点杂交已被实时定量PCR所取代。我们测试了两种最常用的实时PCR仪的灵活性:SDS7700或\'TaqMan\'(TM)(应用生物系统)和LightCycler(LC)(Roche)仪器。克隆T细胞受体和免疫球蛋白基因重排用于使用种系水解探针和克隆特异性引物进行MRD检测。使用两台机器对49例ALL患儿在诊断或复发时的治疗过程中,对90个骨髓样本中的65个克隆基因重排和MRD定量进行了敏感性测试。两种实时PCR系统都为所有后续样品中的MRD定量提供了特定结果。总之,我们能够证明TM和LC实时PCR技术产生相似的MRD定量结果,并且定量测定可以很容易地从一个检测系统转移到另一个检测系统。使用相同的检测格式,这两种技术可以联合应用于多中心MRD研究.
    Quantification of residual leukemic cells at early time points during therapy can reliably predict the outcome in children with acute lymphoblastic leukemia (ALL). Recently, semiquantitative minimal residual disease (MRD) detection assays such as dot-blot hybridization have been replaced by real-time quantitative PCR. We tested the flexibility of the two most used real-time PCR machines: the SDS 7700 or \'TaqMan\' (TM) (Applied Biosystems) and the LightCycler (LC) (Roche) instruments. Clonal T-cell receptor and immunoglobulin gene rearrangements were used for MRD detection with germline hydrolyzation probes and clone-specific primers. Sensitivity tests for 65 clonal gene rearrangements and MRD quantification in 90 bone marrow samples during therapy of 49 children with ALL at diagnosis or relapse were performed with both machines. Both real-time PCR systems provided specific results for MRD quantification in all follow-up samples. In conclusion, we were able to demonstrate that TM and LC real-time PCR technologies produce similar MRD quantification results and that the quantification assays can be easily transferred from one detection system to the other. Using the same detection format, both techniques can be applied in combination in multicenter MRD studies.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号