Iatrogenic aortic injury

  • 文章类型: Case Reports
    背景:椎弓根螺钉器械手术可导致主动脉假性动脉瘤的发展,这是一种罕见但潜在的严重并发症;因此,这项工作的目的是描述手术后椎弓根螺钉严重迁移引起的胸主动脉假性动脉瘤的情况。
    方法:我们在此报告一名患者,该患者在胸椎固定手术后接受了降主动脉假性动脉瘤的血管内修复术。最初通过右股动脉插入28-80毫米覆膜支架,术中主动脉造影显示造影剂少量外渗。随后,再植入28-140mm覆膜支架.患者在8年随访期间恢复良好。
    结论:脊柱手术引起的血管并发症严重且罕见,需要早期诊断和干预。
    BACKGROUND: Pedicle screw instrument surgeries can result in the development of aortic pseudoaneurysm, which is a rare yet potentially severe complication; therefore, the purpose of this work is to describe the case of pseudoaneurysm of the thoracic aorta caused by the severe migration of a pedicle screw after surgery.
    METHODS: We herein report a patient who underwent endovascular repair for the pseudoaneurysm of the descending thoracic aorta following thoracic vertebral fixation surgery. A 28-80 mm covered stent was initially inserted through the right femoral artery, and intraoperative aortography revealed a minor extravasation of contrast material. Subsequently, an additional 28-140 mm covered stent was implanted. The patient recovered well during the 8-year follow-up period.
    CONCLUSIONS: Vascular complications resulting from spinal surgery are severe and rare, necessitating early diagnosis and intervention.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Case Reports
    Case reports and review of the literature with a proposed management algorithm.
    To report two cases of a potential vascular complication due to an incorrectly placed pedicle screw (PS) during spine deformity surgery. Relevant literature regarding the management of vascular complications is reviewed, and an evidence-based management algorithm is proposed. Aortic lesions represent a rare but potentially life-threatening complications with spine deformity and revision surgery, significantly increasing the risk. A management algorithm for an aortic lesion in the case of a malpositioned PS has not yet been published.
    Case 1: An 18-year-old female with proximal thoracic spinal non-instrumented fusion underwent a revision corrective procedure due to a progressive right-sided thoracolumbar compensatory curve. However, postoperative computed tomography (CT) performed to evaluate the position of the PS revealed malposition of the left T9 PS, which was abutting the descending aorta with CT angiography excluding the perforation of the aorta. Case 2: A 17-year-old male was scheduled for correction of Lenke 3-C-N adolescent idiopathic scoliosis. Postoperative routine evaluation with low-dose CT revealed a left T9 PS paravertebral malposition, and subsequent CTA demonstrated that the thread of the PS was in contact with the descending thoracic aorta and an unlikely hemodynamically significant vessel injury.
    Successful removal of both malpositioned PS was performed. In the first case, a cardiovascular surgeon attended the operation if an urgent thoracotomy was needed, and in the second case, additional video-assisted thoracoscopic control of the aorta was performed during PS removal.
    Preoperative imaging in spinal surgery is essential to avoid major vascular and other complications when placing PS, especially in thoracic deformities. When a potential major vessel complication emerges, an interdisciplinary approach and an appropriate management algorithm are mandatory to make the best clinical decisions.
    4.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    UNASSIGNED: Aortic injuries during non-aortic related procedures are rare but potentially catastrophic. Endovascular aortic repair has been described as a viable option in similar circumstances. However, most reports involve aortic injury from orthopaedic hardware after spine surgery or trocar injury during abdominal surgery.
    UNASSIGNED: This is a report of a thoracic aortic injury during thoracostomy tube placement and summary of the management paradigm. The patient was treated with a thoracic stent graft and was seen at four-month follow up, with imaging showing the endograft in stable position.
    UNASSIGNED: Endovascular stenting can increase the treatment scope for management of emergent thoracic aortic pathology.