{Reference Type}: Case Reports
{Title}: Endovascular repair for thoracic aortic pseudoaneurysm induced by pedicle screw implantation: a case report with 8 years follow-up.
{Author}: Zhou S;Han H;Zhang Y;Shu C;Luo M;
{Journal}: J Cardiothorac Surg
{Volume}: 19
{Issue}: 1
{Year}: 2024 Jun 7
{Factor}: 1.522
{DOI}: 10.1186/s13019-024-02820-w
{Abstract}: BACKGROUND: Pedicle screw instrument surgeries can result in the development of aortic pseudoaneurysm, which is a rare yet potentially severe complication; therefore, the purpose of this work is to describe the case of pseudoaneurysm of the thoracic aorta caused by the severe migration of a pedicle screw after surgery.
METHODS: We herein report a patient who underwent endovascular repair for the pseudoaneurysm of the descending thoracic aorta following thoracic vertebral fixation surgery. A 28-80 mm covered stent was initially inserted through the right femoral artery, and intraoperative aortography revealed a minor extravasation of contrast material. Subsequently, an additional 28-140 mm covered stent was implanted. The patient recovered well during the 8-year follow-up period.
CONCLUSIONS: Vascular complications resulting from spinal surgery are severe and rare, necessitating early diagnosis and intervention.