%0 Case Reports %T Endovascular Thoracic Aortic Repair for Catheter Associated Aortic Injury During Thoracostomy Tube Placement. %A Skripochnik E %A Sattari AR %A Bilfinger TV %A Tassiopoulos AK %A Bannazadeh M %J EJVES Short Rep %V 46 %N 0 %D 2020 %M 31879704 暂无%R 10.1016/j.ejvssr.2019.11.002 %X UNASSIGNED: Aortic injuries during non-aortic related procedures are rare but potentially catastrophic. Endovascular aortic repair has been described as a viable option in similar circumstances. However, most reports involve aortic injury from orthopaedic hardware after spine surgery or trocar injury during abdominal surgery.
UNASSIGNED: This is a report of a thoracic aortic injury during thoracostomy tube placement and summary of the management paradigm. The patient was treated with a thoracic stent graft and was seen at four-month follow up, with imaging showing the endograft in stable position.
UNASSIGNED: Endovascular stenting can increase the treatment scope for management of emergent thoracic aortic pathology.