water bath

  • 文章类型: Journal Article
    背景:用于超声检查的传统水浴将手放入一锅水中,并将超声探头浸入水中。虽然这改善了超声传输并将结构移动到焦点区域以制作更高分辨率的图像,这种方法确实有局限性。病人必须直接在探头下操作,这可能受到疼痛或正常运动限制的限制。探针还必须非常静止地保持在水中以最小化运动伪影。横向进近水浴方法通过在不浸没探针的情况下通过薄壁塑料容器的侧面成像来解决此类限制。这减少了通过柱状浴的侧面成像来进行患者操作的大量需要,它具有360度的成像自由度。它还使探头直接靠在平板上稳定,坚固的容器,以减少图像退化的运动伪影。我们假设,由于这些改进,横向进近水浴可能会比传统水浴产生更高质量的图像。
    方法:我们比较了每种方法的20张图像,这是用相同的模型和超声操作者在同一时间获得的。两名受过超声研究训练的盲人审阅者以1至5的等级对图像的质量和临床决策的充分性进行了评分。
    结果:侧面水浴的图像质量更好,与传统浴缸的2.6相比,平均评级为4.2(p<0.001)。侧向入路浴的平均评分为4.0,而传统浴的评分为2.6(p<0.001),辅助临床决策的充分性更好。侧浴还具有较小的图像质量范围,因此具有较大的一致性。
    结论:横向进路水浴是一种手成像方法,可产生更高质量,更一致,和更多的临床有用的图像比传统的水浴成像。
    Traditional water baths for ultrasound exams place a hand into a pan of water and submerge an ultrasound probe into the water. While this improves ultrasound transmission and moves structures into the focal zone to make higher resolution images, this method does have limitations. Patients must be manipulated directly under the probe, which can be limited by pain or normal movement restrictions. The probe must also be held very still in water to minimize motion artifact. The lateral approach water bath method addresses such limitations by imaging through the side of a thin-walled plastic container without submerging the probe. This reduces much need for patient manipulation by imaging through the side of a column-shaped bath, which has 360 degrees of imaging freedom. It also stabilizes the probe directly against the flat, firm container to reduce image degrading motion artifact. We hypothesized that because of these improvements the lateral approach water bath might create higher quality images than traditional water baths.
    We compared twenty images from each method, which were obtained with the same model and ultrasound operator at the same time. Two ultrasound fellowship trained blinded reviewers rated the images for quality and adequacy for clinical decision making on a scale from 1 to 5.
    Image quality was better for the lateral water bath, with an average rating of 4.2 compared to the traditional bath\'s 2.6 (p < 0.001). Adequacy to aid clinical decision making was better for the lateral approach bath with an average rating of 4.0 compared to the traditional bath\'s 2.6 (p < 0.001). The lateral bath also had a smaller range for image quality and thus greater consistency.
    The lateral approach water bath is a method of hand imaging that produces higher quality, more consistent, and more clinically useful images than traditional water bath imaging.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    免疫组织化学(IHC)的细胞阻滞(CB)在浆液性积液的诊断检查中实际上是必不可少的;但是,CB需要至少15-20小时进行常规组织病理学处理。处理时间的减少可以加快更快的诊断。
    进行这项研究以评估热致CB(HICB)技术的实用性。
    从50个渗出液样品中处理两组琼脂包埋的CB。通过常规和快速方法进一步处理CB。常规CB(CCB)在组织处理器中进行处理,而快速CB是在带有搅拌设备的加热水浴中处理的。对于HICB处理,在50°C下进行脱水和澄清,然后在65°C温度下进行石蜡浸渍。从两个CB中,切取5μm厚的切片并用苏木精和伊红(H和E)染色。细胞形态学,成本,并对两种方法的时间进行了比较。在少数情况下尝试了IHC的可行性。
    与CCB相比,HICB在4.30h内完成。在所有情况下,两个CB的诊断都是一致的。在6例(12%)中发现脱水不完全,但诊断并未受损.HICB不涉及额外费用。在IHC上,HICB和CCB表达相当。
    HICB是一种快速,创新,简单,和具有成本效益的技术,并加快更快的诊断。它不需要任何先进的设备。
    UNASSIGNED: Cellblock (CB) with immunohistochemistry (IHC) is practically indispensable in the diagnostic workup of serous effusions; however, CB requires a minimum of 15-20 h for routine histopathological processing. A reduction in processing time can expedite a faster diagnosis.
    UNASSIGNED: This study was undertaken to evaluate the utility of the heat-induced CB (HICB) technique.
    UNASSIGNED: Two sets of agar-embedded CBs were processed from 50 effusion samples. CBs were further processed by conventional and rapid methods. Conventional CBs (CCB) were processed in a histoprocessor, whereas rapid CB was processed in a heated water bath with an agitation facility. For HICB processing, dehydration and clearing were performed at 50°C followed by paraffin wax impregnation at 65°C temperature. From both CBs, sections of 5 um thickness were cut and stained with hematoxylin and eosin (H and E). Cell morphology, cost, and time were compared between the two methods. The feasibility of IHC was attempted in a few cases.
    UNASSIGNED: HICB was completed within 4.30 h compared with CCB. Diagnoses on both CBs were concordant in all the cases. Incomplete dehydration was noted in six (12%) cases, but the diagnosis was not compromised. No additional cost was involved in HICB. On IHC, both HICB and CCB exhibited equivalent expression.
    UNASSIGNED: HICB is a rapid, innovative, simple, and cost-effective technique and expedites faster diagnosis. It does not require any advanced equipment.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    作为一种新型的蛋白质资源,螺旋藻蛋白(SPP)的低消化率限制了其大规模应用。从食品加工方法的角度来看,采用不同的热处理方法改善SPP的结构和消化率。在这项研究中,SPP通过水浴和微波以相同的加热速率和加热温度加热。随着加热强度的增加,微波加速蛋白质的变性和结构展开,导致更多暴露的疏水残基和增强表面疏水性。游离巯基的数据,颗粒大小,和凝胶电泳,表明微波处理促进了蛋白质聚集体的形成。结构变化可能会改善消化酶的可及性,提高体外消化率,并进一步加速小分子肽的生产和游离氨基酸的释放。本研究为提高SPP的消化率和利用效率提供了一种创新方法。
    As a novel protein resource, the low digestibility of Spirulina platensis protein (SPP) limits its large-scale application. From the perspective of food processing methods, different heating treatments were explored to improve the structure and digestibility of SPP. In this study, SPP was heated by water bath and microwave at the same heating rate and heating temperature. Microwave accelerated protein denaturation and structure unfolded as the heating intensity increases, causing more exposed hydrophobic residues and enhancing surface hydrophobicity. The data of free sulfhydryl group, particle size, and gel electrophoresis, showed that microwave treatment promoted the formation of protein aggregates. The structural changes can potentially improve the accessibility of digestive enzymes, promote the in vitro digestibility rate, and further accelerate the production of small molecular peptides and the release of free amino acids. This study provided an innovative approach to improve the digestibility and therefore the utilization efficiency of SPP.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    目的本研究旨在评估在不同体外条件下使用445nm二极管激光后钛和陶瓷植入物的温度变化。方法将钛(Ti)和陶瓷(Zr)牙科植入物放入骨类似物中,每个植入物都会产生骨内缺损。使用445nm二极管激光器照射缺陷30秒,非接触,在2W连续波(c.w.)和脉冲模式。实验在室温(21.0°C±1)和水浴(37.0°C±1)中进行。使用两个热电偶探针记录植入物冠状部分(Tc)和顶点(Ta)的实时温度变化(°C)。在时间0s(To)和照射30s后(Tf)记录温度。计算平均温度变化,并进行了描述性分析(p<0.05)。结果在21°C下使用连续波,Ti植入物在冠状(29.6°C)和顶部(6.7°C)产生最高ΔT值。Zr植入物冠部升高至26.4°C,顶部升高至5.2°C。在水浴中,Ti和Zr植入物的冠状部分上升到14.2°C和14.01°C,分别,使用连续波。当使用脉冲模式放置在水浴中时,Ti的ΔT值为冠状11.9°C,顶部为1.7°C。ΔT最低发生在Zr植入物上,ΔTc和ΔTa,4.8°C和0.78°C,分别。结论在体外条件下,脉冲模式下的445nm二极管激光器似乎可以安全地用于陶瓷植入物,在钛植入物上应谨慎使用。
    This study aimed to evaluate temperature changes in titanium and ceramic implants after using a 445-nm diode laser under different in vitro conditions. Titanium (Ti) and ceramic (Zr) dental implants were placed into a bone analog, and an intrabony defect was created at each implant. A 445-nm diode laser was used to irradiate the defects for 30 seconds, noncontact, at 2 W in continuous wave (c.w.) and pulsed mode. The experiment was done at room temperature (21.0 ± 1°C) and in a water bath (37.0 ± 1°C). Two thermocouple probes were used to record real-time temperature changes (°C) at the coronal part of the implant (Tc) and the apex (Ta). The temperature was recorded at time 0 (To) and after 30 seconds of irradiation (Tf). The average temperature change was calculated, and a descriptive analysis was conducted (P < .05). The Ti implant resulted in the highest ΔT values coronally (29.6°C) and apically (6.7°C) using continuous wave at 21°C. The Zr implant increased to 26.4°C coronally and 5.2°C apically. In the water bath, the coronal portion of the Ti and Zr implants rose to 14.2°C and 14.01°C, respectively, using continuous waves. The ΔT values for Ti were 11.9°C coronally and 1.7°C apically when placed in a water bath using pulsed mode. The lowest ΔT occurred on the Zr implant with ΔTc and ΔTa of 4.8°C and 0.78°C, respectively. Under in vitro conditions, the 445-nm diode laser in pulsed mode seems to be safe for use on ceramic implants and should be used with caution on titanium implants.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    ZnO是一种宽带隙半导体金属氧化物,不仅具有优异的电学性能,而且还表现出优异的气敏性能,是开发NO2传感器的有前途的材料。然而,目前基于ZnO的气体传感器通常在高温下工作,大大增加了传感器的能耗,不利于实际应用。因此,需要提高ZnO基气体传感器的气体灵敏度和实用性。在这项研究中,通过简单的水浴方法在60°C下成功合成了三维片花ZnO,并通过不同的苹果酸浓度进行了调制。相的形成,表面形态,通过各种表征技术研究了所制备样品的元素组成。基于片花ZnO的气体传感器对NO2具有很高的响应值,无需任何修饰。最佳工作温度为125°C,对1ppmNO2的响应值为125。同时,该传感器还具有较低的检测极限(100ppb),良好的选择性,稳定性好,表现出优异的传感性能。在未来,基于水浴的方法有望制备具有独特结构的其他金属氧化物材料。
    ZnO is a wide band gap semiconductor metal oxide that not only has excellent electrical properties but also shows excellent gas-sensitive properties and is a promising material for the development of NO2 sensors. However, the current ZnO-based gas sensors usually operate at high temperatures, which greatly increases the energy consumption of the sensors and is not conducive to practical applications. Therefore, there is a need to improve the gas sensitivity and practicality of ZnO-based gas sensors. In this study, three-dimensional sheet-flower ZnO was successfully synthesized at 60 °C by a simple water bath method and modulated by different malic acid concentrations. The phase formation, surface morphology, and elemental composition of the prepared samples were studied by various characterization techniques. The gas sensor based on sheet-flower ZnO has a high response value to NO2 without any modification. The optimal operating temperature is 125 °C, and the response value to 1 ppm NO2 is 125. At the same time, the sensor also has a lower detection limit (100 ppb), good selectivity, and good stability, showing excellent sensing performance. In the future, water bath-based methods are expected to prepare other metal oxide materials with unique structures.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    背景:淀粉-脂质复合物是一种新型的抗性淀粉,这对于预防糖尿病等慢性病具有重要意义。大多数淀粉-脂质复合物通常需要通过加热来处理,以使它们对于各种应用是理想的,并且淀粉基食品通常在没有热处理过程的情况下是不可食用的。然而,淀粉-脂质复合物加热后的消化和结构性质会发生变化。在这项研究中,采用微波和常规加热处理不同水添加量的脱支藜麦淀粉-油酸复合物(DQS-OA),以及两种方法对物理化学的影响,比较了DQS-OA的消化和结构特性。
    结果:体外消化率结果表明,常规热处理样品的抗性淀粉含量(235.34-269.55gkg-1)明显高于微波处理样品(141.51-157.99gkg-1)。此外,微波处理后,DQS-OA的短程分子有序和晶体结构被破坏,粒径变小。相比之下,热稳定性,常规加热后配合物的焓和结晶度得到改善。复合物在1047/1022cm-1处的比率也增加了。
    结论:这项研究表明,在提高耐消化性方面,常规水浴加热优于微波加热。改善短程和长程分子有序性,促进DQS-OA的形成。此外,随着水添加量的增加,微波或水浴处理对DQS-OA性能的影响越来越大。本文受版权保护。保留所有权利。
    BACKGROUND: A starch-lipid complex is a new type of resistant starch, which is of great importance for the prevention of chronic diseases such as diabetes. Most starch-lipid complexes usually need to be treated by heating to make them suitable for a variety of applications, and starch-based foods are generally not edible without a heat-treatment process. However, the digestion and structural properties of the starch-lipid complex will be changed after heating. In this study, microwave and conventional heating were used to treat debranched quinoa starch-oleic acid complexes (DQS-OA) with different water addition conditions, and the effects of the two methods on the physicochemical, digestive, and structural properties of DQS-OA were compared.
    RESULTS: The results of in vitro digestibility showed that the resistant starch content (235.34-269.55 g kg-1 ) of the conventional heating-treated samples was significantly higher than that the microwave-treated samples (141.51-157.99 g kg-1 ). Moreover, after microwave treatment, the short-range molecular order and crystalline structure of DQS-OA were destroyed and the particle size became smaller. In contrast, the thermal stability, enthalpy, and crystallinity of the complexes after conventional heating were improved. The ratio at 1047/1022 cm-1 of complexes has also been increased.
    CONCLUSIONS: This study demonstrated that conventional water-bath heating was better than microwave heating in increasing digestion resistance, improving the short-range and long-range molecular order, and promoting the formation of DQS-OA. With an increase in water addition, the influence of microwave or water-bath treatment on the properties of DQS-OA became greater. © 2022 Society of Chemical Industry.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    暂无摘要。
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    水浴令人惊叹代表了家禽屠宰中应用最广泛的令人惊叹系统,但在欧盟内部,应使用的电参数的具体指示,如电压,失踪了。这项研究的目的是评估两种市售电气设备(A和B)对不同体重的肉鸡的效率以及测试参数对肉品质的影响。在欧盟批准的屠宰场中,使用两种不同的特技进行了实验试验。6600只肉鸡,分为三个重量组,根据相同的电流频率和强度但不同的电压应用不同的协议。失明的训练有素的操作员评估了无意识状态(角膜反射和翅膀拍打)和死后缺陷(胸出血和黑肉)。角膜反射和瘀点的存在是报告最多的意识体征和死后损伤,分别。不同的重量在尤物A中发挥了重要作用,组间有统计学差异(p<0.01)。考虑到受伤,发现体重与病变之间存在反比关系。结果强调了两种惊人系统的有效性,这些系统应用了考虑动物体重并确保其健康的电气参数的最佳组合。
    Water-bath stunning represents the most-applied stunning system in poultry slaughtering, but within the European Union, specific indications on electric parameters that should be used, such as voltage, are missing. The objective of this study was to evaluate the efficiency of two commercially available types of electrical equipment (A and B) on broilers with different live body weights and the influence of the tested parameters on meat quality. Experimental trials in a European Union-approved slaughterhouse were carried out using two different stunners. 6600 broilers, divided into three weight groups, were stunned applying different protocols based on the same current frequencies and intensity but different voltages. The state of unconsciousness (presence of corneal reflex and wings flapping) and post-mortem defects (pectoral hemorrhages and dark meat) were evaluated by blinded trained operators. The presence of corneal reflex and petechiae were the most reported consciousness signs and post-mortem injuries, respectively. Different weights played an important role within stunner A, registering statistical differences (p < 0.01) among groups. Considering injuries, an inverse relationship between body weight and lesions was found. The results highlighted the effectiveness of both stunning systems applying the best combination of electrical parameters considering the weight of the animal and ensuring its well-being.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    本研究的目的是比较微波和水浴加热法制备的壳聚糖的理化性质。用傅里叶变换红外光谱(FTIR)对这两种方法得到的壳聚糖的结构和理化性质进行了表征,X射线衍射仪(XRD)凝胶渗透色谱(GPC),和扫描电子显微镜(SEM)。FTIR和XRD图谱显示两种热源制备的壳聚糖结构没有显著差异。结果表明,微波加热在60min内成功制备了脱乙酰率为73.86%的壳聚糖,而在相同的加热速率下,使用常规加热方法制备具有相同脱乙酰度(74.47%)的壳聚糖需要更长的时间180min。即使在相同的温度条件下,微波技术可将反应时间大大缩短约1/3,而微波生产的壳聚糖可获得相对较低的分子量和粘度。这些结果表明,微波可以通过分子振动产生的摩擦加热机制有效地促进完全的化学反应,超越了快速加热源,变成更高效的,节能,以及进一步使用硬质虾壳和高度结晶的甲壳类材料的环保方法。
    The aim of this study was to compare the physicochemical properties of chitosan prepared by microwave and water bath heating with an equivalent quantity of heat intake. The structure and physicochemical properties of the chitosan obtained by these two methods were characterized by Fourier transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), gel permeation chromatography (GPC), and scanning electron microscopy (SEM). The FTIR and XRD patterns show that there was no significant difference in the structure of chitosan produced by the two heat sources. The results showed that chitosan with 73.86% deacetylation was successfully prepared by microwave heating within 60 min, while a longer time of 180 min was required for the preparation of chitosan with the same deacetylation degree (74.47%) using the conventional heating method under the same heating rate. Even under the same temperature conditions, microwave technology can greatly reduce the reaction time by approximately 1/3, while the chitosan produced by microwaves can obtain relatively low molecular weight and viscosity. These results showed that microwaves may efficiently promote complete chemical reactions by the friction heating mechanism generated by molecular vibration beyond a rapid heating source, turning into a more efficient, energy-saving, and environmentally friendly method for the further use of rigid shrimp shells and highly crystalline crustacean materials.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Comparative Study
    The aim of this study was to investigate the effect of microwave and traditional water bath on physical and chemical properties of grass carp meat and the impact on saltiness perception. The surface hydrophobicity and Fourier transform infrared spectroscopy (FTIR) results showed that microwave made meat proteins unfold less than water bath. The low degree of protein unfolding of meat cooked by microwave caused the changes in water distribution and the formation of a compact microstructure, which were related to the enhancement of saltiness perception. Furthermore, the meat cooked by microwave had lower cooking loss and shear force compared to traditional water bath. The sodium level remained and the distribution of Na and Cl in meat matrix further demonstrated sensory analysis result that the grass carp meat cooked by microwave was saltier than that cooked by water bath. The current research also provided a new approach to reduce salt consumption in fish cooking for home cooking or food industry.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号