thermal hazards

  • 文章类型: Journal Article
    本文讨论了评论论文中的争论,即5G新无线电(5GNR)和其他蜂窝系统生成的布里渊前体可能是比载波频率的功率穿透深度更深层组织损伤的原因。来自脉冲射频信号(RF-EMF)的布里渊前体的原始理论以及对其可能的健康影响的推测可以追溯到1990年代,并且基于对非常短(纳秒)超宽带宽RF脉冲传播的研究通过水。由于蜂窝电话信号的窄带宽,这种假设对于蜂窝电话信号是不正确的。评论过的论文没有提供替代的基本原理,说明为什么布里渊效应会导致蜂窝和其他通信系统的RF-EMF辐射造成组织损伤。本文还指出了有关组织对RF-EMF的热响应的其他不准确性。
    This article discusses the contention in the commented-upon paper that Brillouin precursors generated by 5G New Radio (5G NR) and other cellular systems are a possible cause of tissue damage at deeper layers of tissue than the power penetration depth of the carrier frequency. The original theory for Brillouin precursors from pulsed radiofrequency signals (RF-EMF) and speculation about their possible health effects dates back to the 1990\'s and was based on studies of the propagation of very short (nanosecond) ultrawide-bandwidth RF pulses through water. This assumption is not correct for cellular telephone signals due to their narrow bandwidth. The commented-on paper provides no alternative rationale as to why Brillouin effects should cause tissue damage from RF-EMF radiation from cellular and other communications systems. Other inaccuracies in this paper concerning thermal responses of tissue to RF-EMF are also noted.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    Toxic gases released from lithium-ion battery (LIB) fires pose a very large threat to human health, yet they are poorly studied, and the knowledge of LIB fire toxicity is limited. In this paper, the thermal and toxic hazards resulting from the thermally-induced failure of a 68 Ah pouch LIB are systematically investigated by means of the Fourier transform infrared spectroscopy (FTIR) and 1/2 ISO full scale test room. The LIBs with higher state of charge (SOC) are found to have greater fire risks in terms of their burning behavior, normalized heat release rate, and fire radiation, as well as the concentration of toxic gases. Specifically, the thermal hazards are evaluated by combining the effects of convective and radiative heat. The major toxic gases detected from the online analysis are CO, HF, SO2, NO2, NO and HCl. Furthermore, Fractional Effective Dose (FED) and Fractional Effective Concentration (FEC) models are used to quantitatively assess the overall gas toxicity. Results show that the effects of irritant gases are much more significant than those of asphyxiant gases. HF and SO2 have much greater toxicity than the other fire gases. The maximum FEC value is approaching the critical threshold in such fire scenarios.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Standard risk evaluations posed by medical implants during magnetic resonance imaging (MRI) includes (i) the assessment of the total local electromagnetic (EM) power (P) absorbed in the vicinity of the electrodes and (ii) the translation of P into a local in vivo tissue temperature increase ∆T (P2∆T) in animal experiments or simulations. We investigated the implant/tissue modeling requirements and associated uncertainties by applying full-wave EM and linear bioheat solvers to different implant models, incident field conditions, electrode configurations, and tissue models. Results show that the magnitude of the power is predominately determined by the lead, while the power distribution, and the P2∆T conversion, is determined by the electrode and surrounding tissues. P2∆T is strongly dependent on the size of the electrode, tissue type in contact with the electrode, and tissue inhomogeneity (factor of >2 each) but less on the modeling of the lead (<±10%) and incident field distribution along the lead (<±20%). This was confirmed by means of full-wave simulations performed with detailed high-resolution anatomical phantoms exposed to two commonly used MRI clinical scenarios (64 and 128 MHz), resulting in differences of less than 6%. For the determination of P2∆T, only the electrode and surrounding tissues must be modeled in great detail, whereas the lead can be modeled as a computationally efficient simplified structure exposed to a uniform field. The separate assessments of lead and electrode reduce the overall computational effort by several orders of magnitude. The errors introduced by this simplification can be considered by uncertainty terms. Bioelectromagnetics. 2019;40:422-433. © 2019 Bioelectromagnetics Society.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    In addition to direct thermal energy from a heating source, a large amount of thermal energy stored in clothing will continuously discharge to skin after exposure. Investigating the thermal hazardous effect of clothing caused by stored energy discharge is crucial for the reliability of thermal protective clothing. In this study several indices were proposed and applied to evaluate the impact of thermal energy discharge on human skin. The heat discharge from different layers of fabric systems was investigated, and the influences of air gaps and applied compression were examined. Heat fluxes at the boundaries of fabric layers and the distribution of heat discharge were determined. Additionally, the correlation between heat storage during exposure and heat discharge after exposure was identified. The results demonstrated that heat discharge to the skin could be correlated with heat storage within the fabric, however, it highly depended on the air gap under clothing, the applied compression, and the insulation provided by the fabric layers. Results from this study could contribute to thoroughly understanding the thermal hazardous effect of clothing and enhance the technical basis for developing new fabric combinations to minimize energy discharge after exposure.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    By means of direct nucleation and growth on the surface of graphene and element doping of cobalt oxide (Co3O4) nano-particles, manganese-cobalt oxide/graphene hybrids (MnCo2O4-GNS) were synthesized to reduce fire hazards of poly(butylene terephthalate) (PBT). The structure, elemental composition and morphology of the obtained hybrids were surveyed by X-ray diffraction, X-ray photoelectron spectrometer and transmission electron microscopy, respectively. Thermogravimetric analysis was applied to simulate and study the influence of MnCo2O4-GNS hybrids on thermal degradation of PBT during combustion. The fire hazards of PBT and its composites were assessed by the cone calorimeter. The cone test results had showed that peak HRR and SPR values of MnCo2O4-GNS/PBT composites were lower than that of pure PBT and Co3O4-GNS/PBT composites. Furthermore, the incorporation of MnCo2O4-GNS hybrids gave rise to apparent decrease of pyrolysis products containing aromatic compounds, carbonyl compounds, carbon monoxide and carbon dioxide, attributed to combined impact of physical barrier for graphene and cat O4 for organic volatiles and carbon monoxide.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号