thermal hazards

  • 文章类型: Journal Article
    在热暴露中的职业工人具有频繁的身体活动,这可能导致热防护服的织物变形。为深入了解织物变形对其热防护和热危害双重性能的影响,用改进的实验仪器模拟织物不同程度的拉伸变形和压缩变形。结果表明,在暴露过程中增加拉伸比降低了织物系统内的热存储,但增加了皮肤吸收的能量。与双层织物体系相比,拉伸比对单层织物的热防护性能具有更大的负面影响。在冷却过程中增加拉伸比减少了向皮肤的热量排放,但是所施加的压缩显着改善了热量排放。此外,建立回归模型来检验织物变形的影响,并证明织物的热危害性能受压缩比受拉伸变形的影响更大。
    Occupational workers in thermal exposure have frequent physical activities that may lead to fabric deformation of thermal protective clothing. To deeply understand the impact of fabric deformation on its dual thermal protective and thermal hazardous performance, a modified experimental instrument was used to simulate different extents of fabric tensile deformation and compression deformation. The results demonstrated that increasing tensile ratios during exposure decreased heat storage within a fabric system, but increased the skin absorbed energy. Tensile ratios had a more negative impact on the thermal protective performance of a single-layer fabric than of a double-layer fabric system. Increasing tensile ratios during cooling decreased heat discharge to the skin, but the applied compression significantly improved the heat discharge. In addition, regression models were established to examine the effect of fabric deformation and demonstrated that the thermal hazardous performance of fabrics was more affected by compression than by tensile deformation.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    地铁隧道围岩的热危害越来越明显,其中围岩中的传热起着至关重要的作用。由于埋深浅,在地面大气周期性温度波动和隧道风周期性温度变化的双重作用下,地铁隧道会遇到更复杂的热交换,但是这个问题还没有得到充分解决。在这项工作中,建立了基于双周期温度边界的隧道围岩瞬态传热模型。开发了求解器来估算围岩的温升和传热。然后通过与先前的经验值和半经验方程的比较,验证了该模型的正确性。结果表明,不同深度的围岩温度仍随简谐波波动,有一些地区受到重复效应的严重影响,例如隧道的上覆地层。围岩一般表现为年循环蓄热,但是总储热量逐年减少,直到趋于稳定。此外,隧道越埋越浅,地温的影响越大,隧道围岩温升越高。该研究为确定隧道围岩的储热量和评价地铁热灾害表现过程提供了一种替代方法。
    Thermal hazards of the surrounding rock of subway tunnels are becoming apparent, in which the heat transfer in the surrounding rock plays a crucial role. Due to the shallow buried depth, the subway tunnel encounters a more complicated heat exchange under the duplicate effects of periodic temperature fluctuation of ground atmosphere and periodic temperature variation of tunnel wind, but this issue has not been fully addressed. In this work, a transient heat transfer model of tunnel surrounding rock based on dual periodic temperature boundaries was established. A solver was developed to estimate the temperature rise and heat transfer of surrounding rock. The correctness of this model was then verified by comparing with previous empirical values and semi-empirical equations. The results show that the temperatures of the surrounding rock at different depths still fluctuate following the simple harmonic waves, and there are some regions that are heavily affected by the duplicate effects, such as the overlying strata of the tunnel. The surrounding rock generally exhibits heat storage in annual cycle, but the total heat storage decreases year by year until it tends to stabilize. Furthermore, the shallower the tunnel is buried, the greater the influence of ground temperature and the higher the temperature rise in the tunnel surrounding rock. This research provides an alternative approach to determine the heat storage of tunnel surrounding rock and evaluates the process of thermal disaster manifestation of subway.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    Toxic gases released from lithium-ion battery (LIB) fires pose a very large threat to human health, yet they are poorly studied, and the knowledge of LIB fire toxicity is limited. In this paper, the thermal and toxic hazards resulting from the thermally-induced failure of a 68 Ah pouch LIB are systematically investigated by means of the Fourier transform infrared spectroscopy (FTIR) and 1/2 ISO full scale test room. The LIBs with higher state of charge (SOC) are found to have greater fire risks in terms of their burning behavior, normalized heat release rate, and fire radiation, as well as the concentration of toxic gases. Specifically, the thermal hazards are evaluated by combining the effects of convective and radiative heat. The major toxic gases detected from the online analysis are CO, HF, SO2, NO2, NO and HCl. Furthermore, Fractional Effective Dose (FED) and Fractional Effective Concentration (FEC) models are used to quantitatively assess the overall gas toxicity. Results show that the effects of irritant gases are much more significant than those of asphyxiant gases. HF and SO2 have much greater toxicity than the other fire gases. The maximum FEC value is approaching the critical threshold in such fire scenarios.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    In addition to direct thermal energy from a heating source, a large amount of thermal energy stored in clothing will continuously discharge to skin after exposure. Investigating the thermal hazardous effect of clothing caused by stored energy discharge is crucial for the reliability of thermal protective clothing. In this study several indices were proposed and applied to evaluate the impact of thermal energy discharge on human skin. The heat discharge from different layers of fabric systems was investigated, and the influences of air gaps and applied compression were examined. Heat fluxes at the boundaries of fabric layers and the distribution of heat discharge were determined. Additionally, the correlation between heat storage during exposure and heat discharge after exposure was identified. The results demonstrated that heat discharge to the skin could be correlated with heat storage within the fabric, however, it highly depended on the air gap under clothing, the applied compression, and the insulation provided by the fabric layers. Results from this study could contribute to thoroughly understanding the thermal hazardous effect of clothing and enhance the technical basis for developing new fabric combinations to minimize energy discharge after exposure.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    By means of direct nucleation and growth on the surface of graphene and element doping of cobalt oxide (Co3O4) nano-particles, manganese-cobalt oxide/graphene hybrids (MnCo2O4-GNS) were synthesized to reduce fire hazards of poly(butylene terephthalate) (PBT). The structure, elemental composition and morphology of the obtained hybrids were surveyed by X-ray diffraction, X-ray photoelectron spectrometer and transmission electron microscopy, respectively. Thermogravimetric analysis was applied to simulate and study the influence of MnCo2O4-GNS hybrids on thermal degradation of PBT during combustion. The fire hazards of PBT and its composites were assessed by the cone calorimeter. The cone test results had showed that peak HRR and SPR values of MnCo2O4-GNS/PBT composites were lower than that of pure PBT and Co3O4-GNS/PBT composites. Furthermore, the incorporation of MnCo2O4-GNS hybrids gave rise to apparent decrease of pyrolysis products containing aromatic compounds, carbonyl compounds, carbon monoxide and carbon dioxide, attributed to combined impact of physical barrier for graphene and cat O4 for organic volatiles and carbon monoxide.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)