miniplate

Miniplate
  • 文章类型: Journal Article
    使用非线性有限元分析(FEA)比较微型板和组合微型板-微型板的生物力学参数,以固定zygomaticomax2004复合体(ZMC)骨折。
    制备ZMC断裂模型的两个样品。在样本1(S1)中,骨折用微型钢板稳定,在样本2(S2)中,用微型平板加上微型平板。采用有限元分析软件测量位移,VonMises应力分布(VMSD),和最大主应力分布(MPSD)。
    两个样品的L形板的位移均为6.7μm,S1侧边缘板中的4.4μm,S2侧边缘板中的4.8μm,S1底缘板中的5.8μm,在S2底部边缘板中和5.6μm。S1侧边缘板中的VMSD为41.1MPa,S2侧缘板24.3MPa,S1L型板中的7.6MPa,在S2L形板中9.6MPa,S1底部边缘板中的28.5MPa,和11.8MPa在S2底部边缘板。S1侧边缘板的MPSD为46.2MPa,S2侧边缘板中的26.4MPa,S1L型板中3.6MPa,在S2L形板中4.2MPa,S1底边板30.9MPa,和14.1MPa在S2底部边缘板。
    两个样品中的L形和横向边缘板的位移量最高和最低,分别。两个样品中的侧边缘板具有最高的VMSD和MPSD,S1高于S2。L形板在两个样品中具有最低的VMSD和MPSD。
    UNASSIGNED: To compare the biomechanical parameters of microplates and the combined miniplate-microplate for fixing zygomaticomaxillary complex (ZMC) fractures using nonlinear finite element analysis (FEA).
    UNASSIGNED: Two samples of ZMC fracture models were prepared. In sample 1 (S1), the fractures were stabilized with microplates, and in sample 2 (S2), with miniplates plus microplates. FEA software was used to measure the displacement, Von Mises stress distribution (VMSD), and maximum principal stress distribution (MPSD).
    UNASSIGNED: The displacement was 6.7 μm in the L-shaped plate of both samples, 4.4 μm in the S1 lateral-edge plate, 4.8 μm in the S2 lateral-edge plate, 5.8 μm in the S1 bottom-edge plate, and 5.6 μm in the S2 bottom-edge plate. The VMSD was 41.1 MPa in the S1 lateral-edge plate, 24.3 MPa in the S2 lateral-edge plate, 7.6 MPa in the S1 Lshaped plate, 9.6 MPa in S2 L-shaped plate, 28.5 MPa in the S1 bottom-edge plate, and 11.8 MPa in the S2 bottom-edge plate. The MPSD was 46.2 MPa in the S1 lateral-edge plate, 26.4 MPa in the S2 lateral-edge plate, 3.6 MPa in S1 L-shaped plate, 4.2 MPa in S2 L-shaped plate, 30.9 MPa in S1 bottom-edge plate, and 14.1 MPa in the S2 bottom-edge plate.
    UNASSIGNED: The L-shaped and lateral-edge plates in both samples had the highest and lowest amount of displacement, respectively. The lateral-edge plates in both samples had the highest VMSD and MPSD, which was higher in S1 than S2. The L-shaped plate had the lowest VMSD and MPSD in both samples.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    背景/目标:由于微型板在确保稳定性和加速恢复方面的功效,使用微型板在正颌手术后稳定骨骼的普及度激增。然而,关于手术后应该如何使用这些微型钢板存在争议。一些外科医生主张移除它们,而其他人则建议将它们留在原处。这项研究试图评估频率,原因,以及与正颌手术中微型板去除相关的潜在风险因素。方法:通过审查来自各种数据库的研究,包括PubMed,谷歌学者,Embase,还有Scopus,重点关注1989年至2023年的出版物。结果:十项符合纳入标准的研究,包括1603名患者,选择纳入荟萃分析。男女比例从0.7:1到4:1不等。总的来说,插入5595个微型板,随后删除了294个(5.3%)。移除微型钢板的主要原因包括感染(161例,2.9%),微型板暴露(34例,0.6%),和明显的钢板(23例,0.4%)。其他适应症包括疼痛,患者偏好,和温度敏感性。小钢板切除的不常见原因包括鼻窦炎,二次手术,和牙科病理学。微型板去除的平均持续时间为5.5个月,大多数(56.1%)从下颌骨而不是上颌骨中移除。总之,这项荟萃分析强调了在硬件导致并发症和身体不适时移除微型钢板的重要性.移除微型平板的主要原因是感染和平板暴露,下颌骨是最常见的切除部位。结论:这些发现强调需要继续监测以评估正颌手术中微型板的命运,并为将来的临床决策提供有价值的信息。
    Background/Objectives: The use of miniplates for stabilizing bones post orthognathic surgery has surged in popularity due to their efficacy in ensuring stability and hastening recovery. However, controversy exists regarding what should be done with these miniplates after surgery. Some surgeons advocate for their removal, while others suggest leaving them in place. This study sought to assess the frequency, causes, and potential risk factors linked with miniplate removal in orthognathic procedures. Methods: A thorough meta-analysis was conducted by scrutinizing studies from various databases including PubMed, Google Scholar, Embase, and Scopus, focusing on publications spanning from 1989 to 2023. Results: Ten studies meeting the inclusion criteria, encompassing 1603 patients, were chosen for inclusion in the meta-analysis. The male-to-female ratio varied from 0.7:1 to 4:1. Overall, 5595 miniplates were inserted, with 294 (5.3%) being subsequently removed. Primary reasons for miniplate removal included infection (161 cases, 2.9%), exposure of miniplates (34 cases, 0.6%), and palpable plates (23 cases, 0.4%). Other indications comprised pain, patient preference, and temperature sensitivity. Less frequent causes for miniplate removal included sinusitis, secondary surgery, and dental pathology. The mean duration of miniplate removal was 5.5 months, with the majority (56.1%) being removed from the mandible rather than the maxilla. In conclusion, this meta-analysis underscores the importance of miniplate removal when hardware causes complications and physical discomfort. The primary reasons for removing miniplates were infection and plate exposure, with the mandible being the most common removal site. Conclusions: These findings emphasize the need for continued monitoring to assess the fate of miniplates in orthognathic surgery and provide valuable information for future clinical decision-making.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    :将三维打印的单个钛板用于上颌前牵引,以消除副作用并获得最大的骨骼效果。本研究旨在探讨使用单个钛板在不同方向和位置的上颌牵拉过程中缝合线的应力分布特征。
    :以相对于法兰克福水平面在0°至60°之间的向前和向下角度施加每侧500g的牵引力,之后,钛板向上和向下移动2和4毫米,分别。量化了具有多个牵伸方向和各种微型板高度的缝合线的变化,以分析其对颌面骨的影响。
    :相对于Frankfort水平面的0-30°的伸出角显示出上颌骨逆时针旋转的趋势。在40°前移角下,在上颌骨观察到平移运动,而50-60°的前伸角度倾向于引起上颌骨顺时针旋转。在梨形孔的下边缘处提高的伸出效率与单个钛板的高度增加有关。
    :各种牵伸方向适用于具有不同类型的垂直骨表面的患者。此外,当钛板位于较低位置时,牵引力表现出增加。
    : A three-dimensional-printed individual titanium plate was applied for maxillary protraction to eliminate side effects and obtain the maximum skeletal effect. This study aimed to explore the stress distribution characteristics of sutures during maxillary protraction using individual titanium plates in various directions and locations.
    : A protraction force of 500 g per side was applied at forward and downward angles between 0° and 60° with respect to the Frankfort horizontal plane, after which the titanium plate was moved 2 and 4 mm upward and downward, respectively. Changes in sutures with multiple protraction directions and various miniplate heights were quantified to analyze their impact on the maxillofacial bone.
    : Protraction angle of 0-30° with respect to the Frankfort horizontal plane exhibited a tendency for counterclockwise rotation in the maxilla. At a 40° protraction angle, translational motion was observed in the maxilla, whereas protraction angles of 50-60° tended to induce clockwise rotation in the maxilla. Enhanced protraction efficiency at the lower edge of the pyriform aperture was associated with increased height of individual titanium plates.
    : Various protraction directions are suitable for patients with different types of vertical bone surfaces. Furthermore, when the titanium plate was positioned lower, the protraction force exhibited an increase.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Case Reports
    此病例报告记录了位于下颌左下区域的实质性根尖周病变的诊断和成功治疗。患者出现临床症状,提示根尖周病理,影像学检查显示有广泛的射线可透性病变。选择的治疗方法包括牙髓干预与手术减压,导致病变的解决和口腔健康的恢复。此病例强调了准确诊断和多学科治疗方法在解决大的根尖周病变中的重要性。
    This case report documents the diagnosis and successful management of a substantial periapical lesion located in the lower left region of the jaw. The patient presented with clinical symptoms indicative of periapical pathology, and radiographic examination revealed an extensive radiolucent lesion. The chosen treatment approach involved endodontic intervention coupled with surgical decompression, leading to the resolution of the lesion and restoration of oral health. This case underscores the significance of an accurate diagnosis and a multidisciplinary treatment approach in addressing large periapical lesions.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    纳入50例患者,以比较三维(3D)锁定微型钢板与3D标准微型钢板在下颌骨骨折治疗中的疗效。
    50名患者被随机分配到3D锁定微型板组或3D标准微型板组。所有患者随访6个月,比较术后闭塞情况,稳定性和相关的临床并发症,如伤口裂开,感染和钢板/螺钉骨折和精神神经感觉异常。
    术中检查时,所有骨折均已充分固定。每组4例患者有轻度错乱的咬合,A组1例患者和B组2例患者稳定性降低.所有患者均未出现不愈合或不愈合的并发症。A组,25例患者中有1例精神神经感觉异常,2例伤口裂开。此外,B组,两名患者有精神神经感觉异常,另外两名患者有伤口裂开。比较时的数据具有统计学意义(=0.05)。
    我们研究的总体结果使我们得出结论,两种钢板系统均令人满意,并且在下颌骨骨折中用于切开复位和固定时没有统计学上的显着差异。两组的愈合情况均令人满意。
    UNASSIGNED: Fifty patients were included to compare the efficacy of three-dimensional (3D) locking miniplates versus 3D standard miniplates in the management of mandibular fractures.
    UNASSIGNED: Fifty patients were randomly allocated to either 3D locking miniplate group or 3D standard miniplate group. All patients were followed for six months to compare post-operative occlusion, stability and associated clinical complications such as wound dehiscence, infection and plate/screw fracture and mental nerve paraesthesia.
    UNASSIGNED: All the fractures were adequately fixed when checked intraoperatively. Four patients in each group had mildly deranged occlusion, one patient in Group A and two patients in Group B had reduced stability. None of the patients had complications of non-union or malunion. In Group A, one out of 25 patients had mental nerve paraesthesia and two had wound dehiscence. Moreover, in Group B, two patients had mental nerve paraesthesia and two others had wound dehiscence. The data when compared were statistically significant (=0.05).
    UNASSIGNED: The overall result of our study led us to the conclusion that both the plating systems were satisfactory and there is no statistically significant difference when used for open reduction and fixation in mandibular fractures. Healing was satisfactory in both groups.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    UNASSIGNED:下颌骨是唯一可移动的面部颌骨,它在发声和咀嚼等各种功能方面具有辅助作用。因此,由于下颌骨骨折的功能和解剖学重要性,下颌骨骨折的治疗变得不可避免。骨折固定方法和技术随着各种骨接合系统的稳步发展。在这篇文章中,我们讨论了使用新设计的二维(2D)混合V形板治疗下颌骨骨折。
    未经批准:在本文中,我们评估了新开发的2DV形锁定钢板治疗下颌骨骨折的疗效.
    UNASSIGNED:我们评估了12例不同的下颌骨骨折,旁裂,角和髁下区域。根据各种术中和术后参数,定期在临床和放射学上评估治疗结果。
    UNASSIGNED:这项研究的结果表明,使用2D混合V形钢板固定下颌骨骨折有助于解剖复位和功能稳定,并且具有较低的发病率和感染率。
    UNASSIGNED:2D解剖混合V形板可以是常规迷你板和3D板的合适替代品,因为它提供了令人满意的解剖还原和功能稳定性。相对于精神神经定位板和沿着角度区域的板适应要容易得多。
    UNASSIGNED: Mandible is the only mobile facial jaw bone and it aides in various functions such as phonation and mastication. Therefore, management of mandible fracture becomes inevitable due to its functional and anatomical importance. Fracture fixation methods and techniques have steadily evolved with various osteosynthesis systems. In this article, we discuss the management of mandible fracture using a newly designed two-dimensional (2D) hybrid V-shaped plate.
    UNASSIGNED: In this paper, we have evaluated the efficacy of the newly developed 2D V-shaped locking plate in the management of mandibular fractures.
    UNASSIGNED: We have assessed 12 cases of different mandibular fractures ranging from symphysis, parasymphysis, angle and subcondylar region. Treatment outcome was assessed both clinically and radiologically at regular intervals with various intraoperative and postoperative parameters.
    UNASSIGNED: Results of this study suggest that fixation of mandible fracture with the 2D hybrid V-shaped plate facilitates anatomic reduction and functional stability and carries a low morbidity and infection rate.
    UNASSIGNED: The 2D anatomic hybrid V-shaped plate can be a suitable alternative to conventional miniplate and 3D plates as it offers satisfactory anatomic reduction and functional stability. Positioning the plate in relation to the mental nerve and plate adaptation along the angle region are much easier.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    UNASSIGNED:本研究使用有限元分析比较了双侧截骨颌骨骨折与Miniplate固定和重建钢板固定治疗中骨折碎片的稳定性。
    UNASSIGNED:使用CT扫描仪创建3DFE下颌骨模型。建立了两个双侧骨旁下颌骨骨折模型。模型1是用迷你板固定的,模型2用重建板固定。在磨牙区域施加120N的载荷力,在切牙区域施加62.5N的载荷力。这两个模型已导入到ANSY的WorkbenchSoftware中。
    UNASSIGNED:Miniplate固定模型显示碎片之间的间隙比重建板相对减小。但是在这种特定载荷下,两种模型的间隙值都在愈合的生理极限内。分析微型钢板在治疗双侧不对称骨折方面优于重建钢板。
    UNASSIGNED:分析上,微型钢板在治疗双侧截骨骨折方面优于重建钢板。由于在骨折愈合期间咀嚼力减少,两种固定都提供令人满意的愈合。因此,微型钢板和重建钢板均可作为双侧肩胛骨骨折的固定方法。
    UNASSIGNED: The present study compared the stability of fracture fragments in the management of bilateral parasymphysis mandible fracture with Miniplate fixation and Reconstruction plate fixation using finite element analysis.
    UNASSIGNED: 3D FE Mandible model was created using CT scanner. Two bilateral parasymphysis mandible fracture models were created. Model 1 was fixed with Miniplates, and Model 2 was fixed with Reconstruction plate. Loading forces of 120 N at molar region and 62.5 N at incisor region were applied. These two models were imported to ANSY\'S Workbench Software.
    UNASSIGNED: Miniplate fixation model showed comparatively reduced gap between fragments than Reconstruction plate. But the gap values of both the models were within the physiologic limit of healing under this specific loading. Analytically Miniplates were superior to Reconstruction plate in the management of bilateral parasymphysis fracture.
    UNASSIGNED: Analytically Miniplates are superior to Reconstruction plate in the management of bilateral parasymphysis fracture. As the masticatory forces were reduced during fracture healing period, both fixations provide satisfactory healing. So both Miniplate and Reconstruction plate can be considered as fixation method for bilateral parasymphysis mandible fracture.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    由于它们在适用性上的优势,患者特异性(CAD/CAM)重建板越来越多地用于腓骨游离皮瓣下颌骨重建。此外,最近,CAD/CAM微型板,在术后管理方面有进一步的优势,已被介绍。然而,由CAD/CAM系统引起的生物力学条件仍然部分未知。本研究旨在评估CAD/CAM固定器的主要固定稳定性。对于特定于患者的场景,使用有限元分析确定了使用CAD/CAM重建板或CAD/CAM微型板稳定的单节段腓骨游离皮瓣中诱导的生物力学条件。主要输出参数是节间骨表面之间的应变以及由于不同的咬合情况而引起的固定系统中的应力。CAD/CAM微型板导致中骨间隙中更高的机械应变,而CAD/CAM重建钢板固定导致远端骨间间隙的应变较高。对于所有调查的固定系统,固定系统中的应力低于材料的屈服应力,因此不会出现材料破坏。虽然使用CAD/CAM微型板产生的应变值被认为足以促进近骨间间隙中的骨愈合,在远端骨间间隙CAD/CAM重建钢板固定可能会导致更有益的组织应变。预计固定系统不会出现机械故障。
    Due to their advantages in applicability, patient-specific (CAD/CAM) reconstruction plates are increasingly used in fibula free flap mandible reconstruction. In addition, recently, CAD/CAM miniplates, with further advantages in postoperative management, have been introduced. However, biomechanical conditions induced by CAD/CAM systems remain partially unknown. This study aimed to evaluate the primary fixation stability of CAD/CAM fixators. For a patient-specific scenario, the biomechanical conditions induced in a one segmental fibula free flap stabilized using either a CAD/CAM reconstruction plate or CAD/CAM miniplates were determined using finite element analysis. The main output parameters were the strains between intersegmental bone surfaces and stresses in the fixation systems due to different biting scenarios. CAD/CAM miniplates resulted in higher mechanical strains in the mesial interosseous gap, whereas CAD/CAM reconstruction plate fixation resulted in higher strains in the distal interosseous gap. For all investigated fixation systems, stresses in the fixation systems were below the material yield stress and thus material failure would not be expected. While the use of CAD/CAM miniplates resulted in strain values considered adequate to promote bone healing in the mesial interosseous gap, in the distal interosseous gap CAD/CAM reconstruction plate fixation might result in more beneficial tissue straining. A mechanical failure of the fixation systems would not be expected.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    UNASSIGNED:下颌骨联合和骨不对称骨折的外科治疗已从刚性固定发展为微型钢板接骨术的半刚性固定。近年来已经开发了各种微型板系统,包括三维微型板,微孔板和生物可吸收板,并对其优缺点进行了比较和研究。为了克服3D钢板系统在涉及精神神经的骨折中难以适应和固定的缺点,我们研究所设计了一个新的Z板。
    UNASSIGNED:进行了一项体外研究,以使用有限元分析评估具有3D板和双微型板系统的新设计的Z板的生物力学行为。
    UNASSIGNED:我们的研究表明,在犬齿加载和磨牙加载后,新设计的Z板的总结构变形为0.17毫米和0.31毫米,分别。在犬科动物负载后,板的等效vonMises力已经显示出以下结果-Z板在摩尔负载后显示出121.3MPa和58.40MPa的值。
    UNASSIGNED:我们的研究得出结论,Z板产生的应力最低,总结构变形较小,与3D平板和双微型板系统相比,具有优越的稳定性和支撑性。
    UNASSIGNED: Surgical management of mandibular symphysis and parasymphysis fractures has evolved from rigid fixation to semi-rigid fixation with miniplate osteosynthesis. Various miniplate systems have been developed in recent years including three-dimensional miniplate, microplates and bioresorbable plate, and their advantages and disadvantages have been compared and studied. To overcome the shortcomings of 3D plating system such as difficulty in adaptation and fixation in fractures involving the mental nerve, a novel Z plate has been designed by our institute.
    UNASSIGNED: An in vitro study was performed to evaluate the biomechanical behaviour of the newly designed Z plate with 3D plate and two-miniplate system using finite element analysis.
    UNASSIGNED: Our study showed total structural deformation of 0.17 mm and 0.31 mm of newly designed Z plate after canine loading and molar loading, respectively. The equivalent von Mises force for plate after canine loading had shown the following results-Z plate showed values of 121.3 MPa and 58.40 MPa after molar loading.
    UNASSIGNED: Our study concluded that the Z plate produces lowest stresses, lesser total structural deformation, superior stability and support in comparison with the 3D plate and two-miniplate system.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    未经授权:骨折固定术,在当下,是经典的使用迷你盘子。固定下颌角骨折的钢板的位置和数量已经并且仍然在文献中进行了广泛的研究和报道。最近增加的是3D迷你板。
    UNASSIGNED:比较和评估一个2.0mm钛3D微型板固定板(4-孔)和一个2.0mm钛4-孔微型板在下颌角骨折内固定中的生物力学行为。
    UNASSIGNED:要测量断裂时的载荷,最大负载,分别使用3D微型钢板和常规微型钢板进行内固定的最大载荷下的位移。
    未经授权:将五个干燥的尸体下颌骨分成10个半下颌骨。以下颌骨的角度对每个尸体下颌骨进行切片,以模拟不利的下颌角骨折。将获得的半可食性分为实验组(组1和组2),每组5个样品,分别镀有线性迷你板和3D迷你板。最大负载,断裂载荷,和最大载荷下的位移是唯一获得的比较参数。
    UNASSIGNED:与记录平均最大载荷值为106.96N±23.86的3D微型板相比,常规微型板显示出更大的平均最大载荷值为174.93N±54.45。发现断裂载荷和最大载荷下的位移均微不足道。
    UNASSIGNED:这项研究的结果表明,除最大载荷外,上述任何参数在统计学上都没有显着差异,两组之间进行评估。根据Champy的骨合成线,传统的线性微型板可以成功地用于提供令人满意的骨合成,并具有成本效益的决定性优势。
    UNASSIGNED: Fracture fixation, in the present times, is classically done using mini plates. The position and number of plates to fixate a mandibular angle fracture have been and are still extensively researched and reported in the literature. A more recent addition is 3D mini plates.
    UNASSIGNED: To compare and evaluate the biomechanical behavior of one 2.0 mm titanium 3D miniplate fixation plate (4- hole) and one 2.0 mm titanium 4-hole miniplate in internal fixation of mandibular angle fractures.
    UNASSIGNED: To measure load at break, maximum load, and displacement at maximal load for internal fixation done with 3D mini plates and conventional mini plates respectively.
    UNASSIGNED: Five dry cadaveric mandibles were sectioned into 10 hemi-mandibles. Each cadaveric mandible was sectioned at the angle of mandible to simulate unfavorable mandibular angle fracture. The obtained hemimandible were divided into experimental groups (GROUP 1 and GROUP 2) with 5 samples in each group, plated with a linear miniplate and 3D miniplate respectively. Maximal load, Load at break, and displacement at maximum load were the only obtained parameters for comparison.
    UNASSIGNED: Conventional miniplate showed greater mean maximum load values of 174.93 N±54.45 compared to 3D mini plates which recorded a mean maximum load value of 106.96 N ± 23.86. Load at break and displacement at maximum load were found to be both insignificant.
    UNASSIGNED: The results in this study showed statistically no significant difference with any of the above parameters except maximal load, between the two groups evaluated. Conventional linear miniplate according to Champy\'s lines of osteosynthesis can be used successfully for providing satisfactory osteosynthesis with the definitive advantage of cost-effectiveness.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

公众号