glaucoma medical therapies

青光眼药物治疗
  • 文章类型: Journal Article
    UNASSIGNED: This report describes a case of bilateral primary angle closure (PAC) progressing to unilateral end-stage primary angle closure glaucoma (PACG) associated with treatment for coronavirus disease-19 (COVID-19) infection.
    UNASSIGNED: A 64-year-old man came to our attention because of blurred vision after a 2-month hospital stay for treatment of COVID-19 infection. Examination findings revealed PACG, with severe visual impairment in the right eye and PAC in the left eye due to plateau iris syndrome. The patient\'s severe clinical condition and prolonged systemic therapy masked the symptoms and delayed the diagnosis. Medical chart review disclosed the multifactorial causes of the visual impairment. Ultrasound biomicroscopy (UBM) aided in diagnosis and subsequent therapy.
    UNASSIGNED: The cause behind the primary angle closure and the iridotrabecular contact was eliminated by bilateral cataract extraction, goniosynechialysis, and myotic therapy.
    UNASSIGNED: COVID-19 treatment may pose an increased risk for PAC. Accurate recording of patient and family ophthalmic history is essential to prevent its onset. Recognition of early signs of PAC is key to averting its progression to PACG.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    UNASSIGNED: We aim to compare the outcomes of trabeculectomy with mitomycin-C by a fellowship-trained glaucoma surgeon in the first hundred compared to second hundred surgeries.
    UNASSIGNED: Retrospective review of 200 consecutive surgeries from May 2015 to January 2017. Primary outcomes were intraocular pressure (IOP) control and use of IOP-lowering medications. Success between first hundred (Group 1) and second hundred (Group 2) patients were reported using World Glaucoma Association guidelines. Kaplan-Meier survival demonstrated complete success and qualified success. Secondary outcome measures were postoperative complications, bleb interventions and additional procedures.
    UNASSIGNED: We found no statistical difference between the first hundred and second hundred patient\'s postoperative IOP at week 4 (p = 0.17), 3 months (p = 0.74), 6 months (p = 0.46), 12 months (p = 0.47), 18 months (p = 0.13) or at final follow up (p = 0.53). The mean final follow up period was 3.6 ± 0.7 years. Mean IOP reduction in Group 1 was from 27.1 ± 10.8 to 12.6 ± 7.1 (p < 0.0001) and Group 2 from 22.8 ± 8.4 to 11.3 ± 4.2 (p < 0.0001). Kaplan-Meier graphs showed no significant difference in complete success (p = 0.0693) or qualified success (p = 0.0866) between Group 1 and Group 2. Bleb interventions were not statistically significant between two groups. There was a significantly higher rate of complications with the first hundred patients (p < 0.0001).
    UNASSIGNED: Both first hundred and second hundred patient groups achieved statistically similar outcomes in long term IOP control. Significant reduction of complications was achieved in the second group of patients.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    UNASSIGNED: This study aimed to assess details of therapy required to achieve an intraocular pressure (IOP) of ⩽12 mmHg in patients with severe glaucoma of different etiologies.
    UNASSIGNED: Patients with a follow-up of at least 1 year, who fulfilled inclusion criteria were selected, and data analyzed with respect to baseline IOP, number of medications, and/or surgeries required to achieve an IOP of ⩽12 mmHg and ⩾6 mmHg. Final IOP, visual field status and medications/surgery required were noted.
    UNASSIGNED: About 127 eyes of 85 patients met all criteria. There were 48 eyes having primary angle closure glaucoma (PACG), 16 eyes with primary open angle glaucoma (POAG), 17 eyes of juvenile open angle glaucoma (JOAG), and 46 eyes of secondary glaucoma. The mean baseline IOP was 33.14 ± 11.07 mmHg and final IOP 10.25 ± 1.81 mmHg. In the age group >40 years, 29.63% of patients were controlled on medication as compared to 9.09% and 5.71% in the age group of <20 years and 20-40 years (p = 0.007). With a baseline IOP of <25 mmHg, 48.65% required a trabeculectomy, whereas for 25-30, and >30 mmHg, 62.5% and 97.29% respectively, required surgery (p < 0.001).66.67% of patients having mean deviation of -12 to -16 dB (decibels) on Humphrey field analyzer (HFA) underwent surgery to achieve target IOP in comparison to 83.52% who had mean deviation greater than -16 dB (p = 0.036).
    UNASSIGNED: Only 21.26% of severe glaucoma eyes could be controlled on medications alone. A baseline IOP of >25 mmHg, age <40 years and mean deviation worse than -16 dB, had a higher frequency of trabeculectomies to achieve an IOP of ⩽12 mmHg.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    UNASSIGNED: The aim of the present study is to calculate Concavity Shape Index (CSI) in patients with POAG and exfoliative glaucoma (XFG) and correlate CSI with the severity of glaucoma, comparing to control and ocular hypertension (OHT) patients.
    UNASSIGNED: This was a cross‑sectional study with 146 eyes/146 subjects: 37 healthy eyes, 23 eyes with OHT and 86 glaucoma eyes (70 with POAG, 16 with XFG). The severity of glaucoma was scored with the Glaucoma Staging System 2 (GSS2). Corvis ST® was used to calculate CSI.
    UNASSIGNED: Central corneal thickness (CCT) was significantly thinner in POAG (526 ± 40.0 µm) and XFG (520 ± 38.2 µm) than control group (553 ± 28.8 µm). CSI had no significant differences between the groups. XFG had a higher mean of GSS 2 (2.42 ± 1.38) than POAG (1.87 ± 1.55) and OHT (1.87 ± 1.55). OHT had a significantly less deformable cornea than: control (higher A1 length, lower A1 velocity, higher A2 velocity), POAG (higher A1 length, lower A1 velocity, lower deflection amplitude at highest concavity), and XFG group (lower A1 velocity, lower deflection amplitude at highest concavity), which was independent of age and CCT. No significant correlation was found between GSS 2 and CSI.
    UNASSIGNED: OHT patients had stiffer corneas (less deformed by the air puff) when compared to control, POAG or XFG patients. A less deformable cornea could potentially be related to a more resistant LC/peripapillary sclera. As such, this would result in a lesser optic nerve susceptibility to IOP damage.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    UNASSIGNED: To evaluate the effect of IOP lowering on the capillary density of optic nerve head and retinal nerve fiber layer in patients with primary open angle glaucoma.
    UNASSIGNED: Twenty eyes of 14 glaucomatous patients and 15 eyes of nine normal patients were enrolled. The most appropriate hypotonic treatment was applied to every patient. A HD Angio Disc 4.5 scan (Avanti-AngioVue) was performed at baseline and after a month in the glaucomatous eyes. The following parameters were analyzed: Radial Papillary Capillaries (RPC) density, inside disc, peripapillary, superior-hemi, inferior-hemi, quadrants, and peripapillary, hemi-superior, hemi-inferior, and quadrants RNFL thickness. Optic nerve head analysis was also evaluated. In addition, the RPC density and the RNFL were assessed in the eight sectors provided by the software.
    UNASSIGNED: The RPC density did not significantly change after IOP reduction (p > 0.05). The inferior-temporal (p = 0.005) and inferior-nasal sectors (p < 0.001) showed a greater capillary density than the respective superior sectors in healthy eyes. In contrast in the glaucomatous eyes, the superior-nasal exhibited greater capillary density with respect to the inferior-nasal sectors. The aggregate RPC density of the inferior sectors was greater than the superior ones in the control group (p < 0.001). An improvement of the average disc area (p = 0.01) and the average cup volume (p = 0.059) were also observed along with increased RNFL thickness at different locations (all, p < 0.05) after IOP lowering therapy was initiated.
    UNASSIGNED: The glaucomatous eyes presented rarefaction of the radial papillary capillaries density in the inferior sectors, but no significant changes in the density after IOP-lowering medications.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    UNASSIGNED: To determine the face and content validity of an artificial eye model for ab-interno goniotomy (SimulEYE KDB model, InsEYEt, Westlake Village, CA) by surveying ophthalmologists with varying experience using a Kahook Dual Blade (KDB; New World Medical, Rancho Cucamonga, CA, USA) following a 90-min wet-lab course using the model.
    UNASSIGNED: Overall 13 ophthalmologists participated following a surgical simulation session on goniotomy using the goniotomy blade at the 2019 Canadian Ophthalmological Society annual meeting.
    UNASSIGNED: A 17-question survey to assess the face and content validity of the model was given immediately following the surgical simulation session on goniotomy using the goniotomy blade. Responses to each survey question were recorded on a 5-point Likert scale ranging from (1) strongly agree to (5) strongly disagree.
    UNASSIGNED: Respondents rated statements regarding the model with a median response of 1 (Strongly Agree) to 3 (Neither agree or disagree). Mann-Whitney U nonparametric analysis revealed no significant difference in responses between instructor vs. non-instructor or between prior experience vs. no prior experience for any of the survey statements. The model received highest survey ratings for utility in training residents, acquisition of surgical skills, accessibility, and higher likelihood of success with the procedure than theory and observation alone. Lowest ratings were for realism of the model compared to a human cadaveric eye.
    UNASSIGNED: Our results suggest the SimulEYE KDB model is a reasonably cost-effective solution for simulating angle-based surgeries. Additionally, our project shows that experienced ophthalmologists found the artificial eye models useful and helpful for angle-based surgery training.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    UNASSIGNED: To describe Ex-Press P50 failures due to an internal blockage.
    UNASSIGNED: A retrospective series of 248 eyes of 219 patients with Ex-Press P50 surgery was conducted. Of these cases, 18 (7.2%) required surgical revision due to filtration failure with no visible blockages in the gonioscopy and no filtering bleb in the slit lamp examination. In all of these cases, we found fibrosis on the edges of the scleral flap. After dissecting the scleral flap, filtration through the implant was restored spontaneously in 10 (4.0%) cases. In two cases fibrous tissue was observed on the tip of the implant and was necessary to remove it. In 6 (2.4%) cases, there was no filtration despite no visible obstruction and attempts to restore the flow were unsuccessful, requiring extraction of the implant and reconverting to trabeculectomy. Two of the removed devices were sanded until the lumen was visible to ascertain the nature of the obstruction.
    UNASSIGNED: In our series, the most common cause of failure was episcleral fibrosis. In 2.4% of the cases, the blockage was intraluminal and aqueous flow could not be restored.
    UNASSIGNED: In the Ex-Press P50 implant an internal blockage, that is not visible through the proximal or distal orifices, may be the cause of failure. Unblocking by surgical maneuvers is not feasible due to the intraluminal design. These cases can be solved by extraction of the implant and conversion to trabeculectomy.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Use of topical glaucoma medications has been reported to cause ocular surface (OS) discomfort and inflammation. This study explores the profile of inflammatory cytokines and OS symptoms induced in response to preserved and non-preserved drops.
    Prospective, randomized evaluation on 36 treatment-naïve patients over 24 months of three differently preserved glaucoma drop preparations: Preservative-free (PF), polyquad (PQ) and benzalkonium chloride (BAK). Study participants were evaluated at baseline and then at 1, 3, 6, 12 and 24 months while on medication. At each visit, participants completed the OS disease index (OSDI) questionnaire, had basal tear sampling and impression cytology (IC) of the conjunctival epithelium. Quantitative polymerase chain reaction was performed to measure the gene expression of inflammatory cytokines [interleukin (IL)-6, IL-8, IL-10, IL-12A, IL-12B, IL-17A, IL-1β and tumour necrosis factor-α] in the IC samples. Corresponding protein expression of cytokines in tear samples was assessed by the Becton-Dickinson cytometric bead arrays.
    Compared to PF and PQ groups, mRNA and protein expression of IL-6, IL-8 and IL-1β increased in samples from the BAK group in a time-dependent fashion, whereas all other cytokines showed a non-significant increase. In the BAK group, there was a strong correlation between OSDI and the levels of IC/IL-1β (r = .832, R2 = .692 and P = .040); IC/IL-10 (r = .925, R2 = .856 and P = .008) and tear/IL-1β (r = .899, R2 = .808 and P = .014).
    BAK-preserved topical drops stimulate a sterile inflammatory response on the OS within 3 months which is maintained thereafter, whereas PF-drops and PQ-preserved drops showed no significant OS inflammation.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    目的:本研究的目的是在小梁切除术后1个月用眼前节光学相干断层扫描分析明显功能性滤过泡的形态学参数,并在随访6个月时将这些参数与眼压相关联,以预测小梁切除术的短期成功。
    方法:在此横截面中,描述性研究,在小梁切除术1个月后,使用眼前节光学相干断层扫描和交叉线扫描评估明显功能性气泡.
    结果:共55只眼,55例,平均年龄49.29±13.72岁。在眼前段光学相干断层扫描检查中,平均气泡高度和平均气泡壁厚,结膜下积液,巩膜瓣厚度为1.45±0.39mm,0.63±0.25mm,0.64±0.26mm,和0.45±0.068毫米,分别。1个月时眼压与气泡高度呈显著负相关(r=-0.25,p=0.05)。在6个月时,腔的范围与眼压之间存在统计学上的显着负相关(r=-0.318,p=0.018)。Bleb高度与巩膜上间隙呈显著负相关(r=-0.31,p=0.02)。与均匀的壁反射率相比,多反射泡壁在6个月时显示出统计学上显着增加的成功功能泡泡的机会(p=0.00)。在6个月的短期随访中,Bleb功能成功37例(67.3%),不成功18例(32.7%)。
    结论:小梁切除术后1个月,在前节光学相干断层扫描上,具有多种形式的壁反射率的Bleb壁显示,在6个月时功能滤过泡成功的机会增加。1个月前段光学相干断层扫描的气泡壁特征可以预测6个月时气泡的短期成功。
    OBJECTIVE: The aim of the study was to analyze morphological parameters of apparently functional filtering blebs with anterior segment optical coherence tomography at 1 month post trabeculectomy and to correlate these parameters with intraocular pressure at 6 months of follow-up to predict the short-term success of trabeculectomy.
    METHODS: In this cross-sectional, descriptive study, apparently functional blebs were evaluated using anterior segment optical coherence tomography with crossline scans after 1 month of trabeculectomy.
    RESULTS: A total of 55 eyes of 55 cases with mean age 49.29 ± 13.72 years were included in the study. On anterior segment optical coherence tomography examination, the mean bleb height and mean bleb wall thickness, subconjunctival fluid space, and scleral flap thickness were 1.45 ± 0.39 mm, 0.63 ± 0.25 mm, 0.64 ± 0.26 mm, and 0.45 ± 0.068 mm, respectively. There was statistically significant negative correlation between intraocular pressure at 1 month and bleb height (r = -0.25, p = 0.05). There was statistically significant negative correlation between extent of cavity and intraocular pressure at 6 months (r = -0.318, p = 0.018). Bleb height showed significant negative correlation with supra-scleral space (r = -0.31, p = 0.02). Multi reflective bleb walls showed statistically significant increased chances of successful functioning blebs at 6 months as compared to uniform wall reflectivity (p = 0.00).Bleb function was successful in 37 (67.3%) and unsuccessful in 18 (32.7%) in short term of 6 months of follow-up.
    CONCLUSIONS: Bleb walls with multiform wall reflectivity on anterior segment optical coherence tomography at 1 month post trabeculectomy show increased chances of success of functioning filtering bleb at 6 months. Bleb wall characteristics on anterior segment optical coherence tomography at 1 month can predict the short-term success of blebs at 6 months.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    BACKGROUND: The authors describe benefits of the recognised adverse effects of prostaglandin analogues on periocular structures in patients with unilateral proptosis and intraocular pressure rise. This case points to intentional consideration of prostaglandin analogue therapy in this selected cohort of patients with secondary ocular hypertension and proptosis.
    METHODS: A 70-year-old gentleman who presented with a 1-week history of a red and painful right eye associated with tortuous and dilated episcleral blood vessels. Visual acuity was unaffected. A diagnosis of idiopathic orbital inflammatory disease was made by extraocular muscle biopsy. Two weeks later, the patient presented with worsening pain, reduced vision and raised intraocular pressure. The secondary ocular hypertension was successfully treated with topical preserved eye drops, including latanoprost, a prostaglandin analogue. Over 6 months, the patient developed drop intolerance and punctate keratopathy leading to therapy non-adherence. Interestingly, the patient reported improvement in periocular appearance related to prostaglandin-associated periorbitopathy. Ocular surface disease and intraocular pressures were subsequently managed with preservative-free eye drops.
    CONCLUSIONS: Secondary ocular hypertension is not an uncommon consequence of orbital disease. Prostaglandin analogue can act as a double-edged sword in the management of raised intraocular pressure by reducing eye pressure at the cost of developing adverse effects of prostaglandin-associated periorbitopathy. These adverse effects however can be beneficial in the aesthetic rehabilitation of proptosis and associated exposure keratopathy in patients with unilateral orbital disease and probably should be sought as first line treatment in those with proptosis and raised intraocular pressure.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号