Visual score

  • 文章类型: Journal Article
    尽管基因和功能研究取得了进展,常见变异型免疫缺陷(CVID)的及时诊断仍是一项重大挑战.这项探索性研究旨在评估一组新型的CVID生物标志物的诊断性能,结合κ+λ轻链的总和,可溶性B细胞成熟抗原(sBCMA)水平,转换记忆B细胞(smB)和视觉评分。利用逻辑回归进行比较分析,以建立黄金标准测试,特别是抗体反应。我们的研究涵盖了88个主题,包括27个CVID,23选择性IgA缺乏症(SIGAD),20例继发性免疫缺陷(SID)患者和18例健康对照。我们建立了sBCMA的诊断准确性和κ+λ的总和,实现89%和89%的灵敏度(Se)和特异性(Spe),90%和99%,分别。重要的是,sBCMA与所有评估的生物标志物显示出强相关性(总和κ+λ,smB细胞和视觉),而κ+λ的总和是唯一独立于smB细胞或VISUAL的,提示其额外的诊断价值。通过多变量树决策模型,特异性抗体反应和κ+λ的总和是独立的,CVID的特征生物标志物,该模型显示曲线下面积(AUC)为0.946,Se0.85和Spe0.95。这种树决策模型有望提高CVID的诊断效率,强调和κ+λ作为面板内优越的CVID分类器和潜在的诊断标准。
    Despite advancements in genetic and functional studies, the timely diagnosis of common variable immunodeficiency (CVID) remains a significant challenge. This exploratory study was designed to assess the diagnostic performance of a novel panel of biomarkers for CVID, incorporating the sum of κ+λ light chains, soluble B-cell maturation antigen (sBCMA) levels, switched memory B cells (smB) and the VISUAL score. Comparative analyses utilizing logistic regression were performed against established gold-standard tests, specifically antibody responses. Our research encompassed 88 subjects, comprising 27 CVID, 23 selective IgA deficiency (SIgAD), 20 secondary immunodeficiency (SID) patients and 18 healthy controls. We established the diagnostic accuracy of sBCMA and the sum κ+λ, achieving sensitivity (Se) and specificity (Spe) of 89% and 89%, and 90% and 99%, respectively. Importantly, sBCMA showed strong correlations with all evaluated biomarkers (sum κ+λ, smB cell and VISUAL), whereas the sum κ+λ was uniquely independent from smB cells or VISUAL, suggesting its additional diagnostic value. Through a multivariate tree decision model, specific antibody responses and the sum κ+λ emerged as independent, signature biomarkers for CVID, with the model showcasing an area under the curve (AUC) of 0.946, Se 0.85, and Spe 0.95. This tree-decision model promises to enhance diagnostic efficiency for CVID, underscoring the sum κ+λ as a superior CVID classifier and potential diagnostic criterion within the panel.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    (1)背景:计算机断层扫描(CT)在COVID-19的表征和随访中起着至关重要的作用。已经实施了几种评分系统来正确评估SARS-CoV-2感染患者的肺实质,例如视觉定量评估评分(VQAS)和基于软件的定量评估评分(SBQAS),以帮助管理SARS-CoV-2感染患者。本研究旨在调查和比较两种基于人工智能(AI)的不同类型软件对SARS-CoV-2患者的VQAS和SBQAS的诊断准确性。(2)方法:本研究为回顾性研究,共纳入90例患者,符合以下标准:患者年龄超过18岁,2021年3月至6月期间获得的COVID-19阳性检测和未增强胸部CT扫描。VQAS是独立评估的,使用两种不同的人工智能驱动软件程序(Icolung和CT-COPD)进行SBQAS.采用组内相关系数(ICC)统计指数和Bland-Altman图。(3)结果:放射科医师(R1和R2)对CT图像中涉及的肺实质的VQAS的一致性评分良好(ICC=0.871)。SBQAS的两种软件类型之间的一致性得分中等(ICC=0.584)。Icolung与视觉评价的中位数(中位数R1-R2)之间的一致性良好(ICC=0.885)。CT-COPD与VQAS中位数(中位数R1-R2)之间的对应关系中等(ICC=0.622)。(4)结论:这项研究显示,VQAS和SBQAS的一致性中等,良好;加强这种方法作为管理COVID-19患者的有价值的工具,人工智能工具与医生专业知识的结合可以为患者提供最准确的诊断和治疗计划。
    (1) Background: Computed tomography (CT) plays a paramount role in the characterization and follow-up of COVID-19. Several score systems have been implemented to properly assess the lung parenchyma involved in patients suffering from SARS-CoV-2 infection, such as the visual quantitative assessment score (VQAS) and software-based quantitative assessment score (SBQAS) to help in managing patients with SARS-CoV-2 infection. This study aims to investigate and compare the diagnostic accuracy of the VQAS and SBQAS with two different types of software based on artificial intelligence (AI) in patients affected by SARS-CoV-2. (2) Methods: This is a retrospective study; a total of 90 patients were enrolled with the following criteria: patients\' age more than 18 years old, positive test for COVID-19 and unenhanced chest CT scan obtained between March and June 2021. The VQAS was independently assessed, and the SBQAS was performed with two different artificial intelligence-driven software programs (Icolung and CT-COPD). The Intraclass Correlation Coefficient (ICC) statistical index and Bland-Altman Plot were employed. (3) Results: The agreement scores between radiologists (R1 and R2) for the VQAS of the lung parenchyma involved in the CT images were good (ICC = 0.871). The agreement score between the two software types for the SBQAS was moderate (ICC = 0.584). The accordance between Icolung and the median of the visual evaluations (Median R1-R2) was good (ICC = 0.885). The correspondence between CT-COPD and the median of the VQAS (Median R1-R2) was moderate (ICC = 0.622). (4) Conclusions: This study showed moderate and good agreement upon the VQAS and the SBQAS; enhancing this approach as a valuable tool to manage COVID-19 patients and the combination of AI tools with physician expertise can lead to the most accurate diagnosis and treatment plans for patients.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    OBJECTIVE: The purposes of this experimental study were to compare the quantitative and qualitative visibility of in-stent restenosis between conventional-resolution CT (CRCT) and ultra-high-resolution CT (U-HRCT) and to investigate the effects of the image reconstruction techniques on the visualization of in-stent restenosis.
    METHODS: A vessel tube with non-calcified plaque in a 3.0-mm stent was scanned by using CRCT and U-HRCT at 4 stent directions (0, 30, 60, and 90 degrees) to the through-plane direction. Hybrid iterative reconstruction (HIR); model-based iterative reconstruction (MBIR); deep-learning-based reconstruction (DLR) were used as reconstruction methods. The lumen size was assessed using the full width at half maximum method, and image quality was visually evaluated using 4-point scale.
    RESULTS: U-HRCT had the significantly wider lumen sizes and narrower stent strut thickness than CRCT in three types of the reconstruction methods (P < 0.01). The lumen sizes for U-HRCT with 90 degrees were narrower than those with the other angle directions regardless of the reconstruction methods. Visual score was significantly higher for U-HRCT than CRCT (3.2 ± 0.7 vs 2.0 ± 0.4, P < 0.001).
    CONCLUSIONS: U-HRCT quantitatively and qualitatively provided better visualization of in-stent restenosis compared to CRCT. Image quality of U-HRCT may be affected by stent angle.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    To investigate the role of diffuse pulmonary ossification (DPO) in disease severity in a population of Idiopathic Pulmonary Fibrosis (IPF) patients. This retrospective study was carried out on 95 IPF patients-44 with DPO on high resolution computed tomography (HRCT) and 51 with no calcifications detected on HRCT. Pulmonary Function Tests (PFTs) acquired nearest to the HRCT were collected. Images were analyzed by two radiologists using a qualitative method, based on HRCT fibrosis visual score, and using a quantitative method, based on histogram-based analysis. The Spearman\'s rank correlation coefficient was used to measure the strength and direction of the linear relationship between HRCT fibrosis score and PFTs; in addition, Spearman\'s rank correlation coefficient was used to explore the relationships between HRCT fibrosis score and quantitative index and between quantitative indexes and PFTs. A weak correlation between HRCT fibrosis score and PFTs was proven (r =-0.014 and p = 0.9347 for FVC (Forced Vital Capacity), r = -0.379 and p = 0.0174 for DLCO (Carbon monoxide diffusing capacity)). We found a moderate negative correlation between HRCT fibrosis score and kurtosis (r = -0.448, p = 0.004272) and skewness (r = -0.463, p = 0.003019) and a weak positive correlation with High Attenuation Area (HAA)% (r = 0.362, p = 0.0235). Moreover, a moderate linear correlation between Quantitative Indexes and FVC (r = 0.577, p = 0.000051 for kurtosis and FVC, r = 0.598, p = 0.000023 for skewness and FVC, r = -0.519, p = 0.0000364 for HAA% and FVC) and between quantitative indexes and DLCO (r = 0.469, p = 0.001508 for kurtosis, and DLCO, r = 0.474, p = 0.001309 for skewness and DLCO, r = -0.412, p = 0.005996 for HAA% and DLCO) was revealed. To better investigate the influence of DPO in disease progression, a longitudinal evaluation should be performed.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Comparative Study
    BACKGROUND: Volumetric high-resolution computed tomography (HRCT) of the chest has recently replaced incremental CT in the diagnostic workup of idiopathic pulmonary fibrosis (IPF). Concomitantly, visual and quantitative scores have been proposed for disease extent assessment to ameliorate disease management.
    OBJECTIVE: To compare the performance of density histograms (mean lung attenuation, skewness, and kurtosis) and visual scores, along with lung function correlations, in IPF patients submitted to incremental or volumetric thorax HRCT.
    METHODS: Clinical data and CT scans of 89 newly diagnosed and therapy-naive IPF patients were retrospectively evaluated.
    RESULTS: Forty-six incremental and 43 volumetric CT scans were reviewed. No differences of density histograms and visual scores estimates were found by comparing two HRCT techniques, with an optimal inter-operator agreement (concordance correlation coefficient >0.90 in all instances). Single-breath diffusing lung capacity for carbon monoxide (DLCOsb) was inversely related with the Best score (r = -00.416; p = 0.014), the Kazerooni fibrosis extent (r = -0.481; p = 0.004) and the mean lung attenuation (r = -0.382; p = 0.026), while a positive correlation was observed with skewness (r = 0.583; p = 0.001) and kurtosis (r = 0.543; p = 0.001) in the incremental HRCT sub-group. Similarly, in the volumetric CT sub-cohort, DLCOsb was significantly associated with skewness (r = 0.581; p = 0.007) and kurtosis (r = 0.549; p = 0.018). Correlations with visual scores were not confirmed. Forced vital capacity significantly related to all density indices independently on HRCT technique.
    CONCLUSIONS: Density histograms and visual scores similarly perform in incremental and volumetric HRCT. Density quantification displays an optimal reproducibility and proves to be superior to visual scoring as more strongly correlated with lung function.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    BACKGROUND: Lung cancer is a frequent comorbidity of chronic obstructive pulmonary disease (COPD). However, the local risk of developing lung cancer related to regional emphysema distribution and clinical outcome has not been investigated. Our aim was to evaluate the impact of regional emphysema score (RES) on tumor location and prognosis in non-small cell lung cancer (NSCLC) patients.
    METHODS: We enrolled 457 patients who underwent curative surgery for NSCLC at seven hospitals at The Catholic University of Korea from 2014 to 2018. Emphysema was visually assessed for each lobe, with the lingula as a separate lobe. Semi-quantitative emphysema scoring was classified as follows: 0 = none, 0.5 = 1 to 10%, 1 = 11 to 25%, 2 = 26 to 50%, 3 = 51 to 75%, and 4 = 76 to 100%. An RES was given to each of the six lung zone: the upper, middle, and lower lobes in the right and left lungs.
    RESULTS: There were 145 patients in the high RES (≥ 3) group and 312 in the low RES (< 3) group. The mean RES in each lobe with cancer was significantly higher than that in other lobes without cancer (0.51 vs. 0.37, P <  0.001). This group showed significantly shorter disease-free survival (P <  0.001), in addition, presence of COPD, low diffusing capacity of the lung for carbon monoxide (< 80), smoking status, and poor differentiation were more frequent in this group. Also, cancer in a lobe with a higher RES (odds ratio (OR) = 1.56; 95% confidence interval (CI:1.01-2.42; P = 0.04), pathologic stage ≥ III (OR = 2.23; 95% CI: 1.28-3.89; P <  0.001), and poor differentiation (OR = 1.99; 95% CI: 1.22-3.21; P <  0.001) were independent factors for tumor recurrence.
    CONCLUSIONS: The regional severity of emphysema by visual qualification was associated with the location of lung cancer, and was an independently poor prognostic factor for tumor recurrence in completely resected NSCLC patients.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    The point-of-care strip assay for the detection of the schistosome Circulating Cathodic Antigen (POC-CCA) in urine has shown to be a user-friendly and sensitive alternative to stool microscopy for the diagnosis of Schistosoma mansoni infections. However, visual scoring of the test is by definition observer dependent and leads to discussion about the qualitative interpretation, in particular in low intensity infections when test lines tend to be weak. In order to standardise visual scoring, an innovative approach for semi-quantitative interpretation of the POC-CCA cassettes, called G-scores, was developed and evaluated. Urines (n = 110) from a S. mansoni endemic area were used to evaluate this new approach. Test lines of the POC-CCA were visually compared against the G-scores, i.e. a series of artificial cassettes containing inkjet-printed strips of different intensities in order to grade the POC-CCA test line on a scale of 1 to 10. A significant positive correlation (Spearman 0.660, p < 0.001) was observed between G-scores and eggs per gram of faeces. This proof-of-concept study demonstrates the usefulness of the G-scores for standardising the visual scoring of the POC-CCA urine strip assay. Several research groups have already indicated an interest in the G-scores for their field work. Further distribution of the cassettes, in particular when provided in combination with reference standards, will assist the wider schistosomiasis community in dealing with issues like batch-to-batch differences and interpretation of trace readings.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Assessment of gait abnormalities in cerebral palsy (CP) is challenging, and access to instrumented gait analysis is not always feasible. Therefore, many observational gait analysis scales have been devised. This study aimed to evaluate the interobserver reliability, intraobserver reliability, and validity of Edinburgh visual gait score (EVGS). Video of 30 children with spastic CP were reviewed by 7 raters (10 children each in GMFCS levels I, II, and III, age 6-12 years). Three observers had high level of experience in gait analysis (10+ years), two had medium level (2-5 years) and two had no previous experience (orthopedic fellows). Interobserver reliability was evaluated using percentage of complete agreement and kappa values. Criterion validity was evaluated by comparing EVGS scores with 3DGA data taken from the same video visit. Interobserver agreement was 60-90% and Kappa values were 0.18-0.85 for the 17 items in EVGS. Reliability was higher for distal segments (foot/ankle/knee 63-90%; trunk/pelvis/hip 60-76%), with greater experience (high 66-91%, medium 62-90%, no-experience 41-87%), with more EVGS practice (1st 10 videos 52-88%, last 10 videos 64-97%) and when used with higher functioning children (GMFCS I 65-96%, II 58-90%, III 35-65%). Intraobserver agreement was 64-92%. Agreement between EVGS and 3DGA was 52-73%. We believe that having EVGS as part of the standardized gait evaluation is helpful in optimizing the visual scoring. EVGS can be a supportive tool that adds quantitative data instead of only qualitative assessment to a video only gait evaluation.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号