  • 文章类型: Journal Article
    肿瘤-血管界面是肿瘤微环境的关键组成部分,可调节生长中的肿瘤与周围脉管系统的内皮衬里之间的所有动态相互作用。在本文中,我们报道了一种定制设计的肿瘤-血管界面系统的设计和开发,用于研究早期肿瘤介导的内皮促血管生成功能失调行为。使用代表性的内皮细胞和三阴性乳腺癌细胞系,我们在成熟的三维肿瘤组织之间建立了仿生界面,使用磁性混合整合的肿瘤-血管界面系统的功能性内皮屏障,其中将在多孔微流体通道表面上包含单层内皮细胞培养物的血管系统样特征磁性附着到在复合聚合物-水凝胶微孔板上产生的肿瘤球体上并嵌入胶原基质中。肿瘤介导的内皮微动力学特征在于其标志性行为,如内皮粘附连接的丧失,细胞密度增加,扩散,和细胞扩散的变化,并与内皮YAP/TAZ核易位证实。我们进一步证实了通过两种不同的信号机制药物介导逆转这种促血管生成内皮细胞的可行性。即,抑制血管内皮生长因子途径和Notch信号通路,从而证明了肿瘤-血管界面平台的实用性,抗血管生成药物疗效的早期预测。总的来说,我们的工作强调了我们的战略工程方法对于识别一些独特的、肿瘤-血管界面的生理相关方面,否则很难使用标准的体外方法来实施。
    The tumor-vascular interface is a critical component of the tumor microenvironment that regulates all of the dynamic interactions between a growing tumor and the endothelial lining of the surrounding vasculature. In this paper, we report the design and development of a custom-engineered tumor-vascular interface system for investigating the early stage tumor-mediated pro-angiogenic dysfunctional behavior of the endothelium. Using representative endothelial cells and triple negative breast cancer cell lines, we established a biomimetic interface between a three-dimensional tumor tissue across a mature, functional endothelial barrier using a magnetically hybrid-integrated tumor-vascular interface system, wherein vasculature-like features containing a monolayer of endothelial cell culture on porous microfluidic channel surfaces were magnetically attached to tumor spheroids generated on a composite polymer-hydrogel microwell plate and embedded in a collagen matrix. Tumor-mediated endothelial microdynamics were characterized by their hallmark behavior such as loss of endothelial adherens junctions, increased cell density, proliferation, and changes in cell spreading and corroborated with endothelial YAP/TAZ nuclear translocation. We further confirm the feasibility of drug-mediated reversal of this pro-angiogenic endothelial organization through two different signaling mechanisms, namely, inhibition of the vascular endothelial growth factor pathway and the Notch signaling pathway, thereby demonstrating the utility of the tumor-vascular interface platform for rapid, early stage prediction of antiangiogenic drug efficacy. Overall, our work emphasizes the importance of our strategic engineering approach for identifying some unique, physiologically relevant aspects of the tumor-vascular interface, which are otherwise difficult to implement using standard in vitro approaches.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • DOI:
    文章类型: Journal Article
    目的:探讨磁性附着体在口腔修复中的作用及临床价值。
    方法:选取2018年4月至2019年10月海曙区口腔医院收治的72例牙体缺损患者进行回顾性分析。其中常规口腔修复36例(对照组),磁性附着体34例(研究组)。临床疗效,不良反应,比较两组患者的咀嚼效率和固定力,出院时对治疗满意度进行调查。随后,对患者进行了为期一年的随访调查.每隔6个月重新检查探查深度(PD)和牙槽骨高度,和沟出血指数(SBI),记录牙齿松动和菌斑指数(PLI)。
    结果:与对照组相比,研究组总有效率较高,不良反应发生率较低(P<0.05)。修复治疗后,咀嚼效率,固定力,研究组患者的舒适度和美学效果均高于对照组(均P<0.05)。后续结果表明,SBI,PD,研究组的PLI和牙齿松动率较低,而牙槽骨高度较高,与对照组比较(均P<0.05)。
    结论:磁性附着体可显著提高口腔修复的效果和安全性,提高咀嚼效率。固定,和患者的牙周康复,这充分说明了磁性附件的临床应用价值。
    OBJECTIVE: To investigate the effect and clinical value of magnetic attachments in oral restoration.
    METHODS: Seventy-two cases of dental defects treated in Haishu District Stomatological Hospital from April 2018 to October 2019 were selected for retrospective analysis, of which 36 cases were treated with routine oral restoration (control group) and 34 cases with magnetic attachments (research group). The clinical efficacy, adverse reactions, masticatory efficiency and fixation force were compared between the two groups, and the treatment satisfaction was investigated at discharge. Subsequently, a one-year follow-up survey was conducted on the patients. The probing depth (PD) and alveolar bone height were re-examined at 6-month intervals, and the sulcus bleeding index (SBI), tooth loosening and plaque index (PLI) were recorded.
    RESULTS: Compared with the control group, the total effective rate was higher in the research group, and the incidence of adverse reactions was lower (P<0.05). After the restoration treatment, the masticatory efficiency, fixation force, comfort and aesthetic outcome in the research group were higher than those in the control group (all P<0.05). The follow-up results showed that the SBI, PD, PLI and tooth loosening rate of the research group were lower while the alveolar bone height were higher, versus the control group (all P<0.05).
    CONCLUSIONS: Magnetic attachments can significantly improve the effect and safety of dental restoration as well as the masticatory efficiency, fixation, and periodontal rehabilitation of patients, which fully illustrates the clinical application value of magnetic attachments.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    目的:采用短种植体的种植体辅助可摘局部义齿(IARPDs)改善可摘局部义齿(RPDs)的口腔功能。这项研究旨在比较RPDs和IARPDs与磁性附件保留的短植入物的患者报告结果。方法我们招募了30名下颌KennedyI级或II级以及三颗或更多颗牙齿的远端延伸缺损的参与者。RPD,带有治疗帽的IARPD,使用患者报告的结局对带有磁性附件的IARPD和IARPD进行了分期评估.所有参与者完成问卷(口腔健康相关生活质量[OHRQoL],患者总体满意度,和患者义齿评估[PDA])在每个阶段。使用口腔健康影响概况-J54(OHIP-J54)评分评估OHRQoL。使用100mm视觉模拟量表评估患者的总体满意度。使用Wilcoxon符号秩检验和Bonferroni校正来评估组间差异(α=0.05)。结果IARPDs的OHRQoL明显高于RPDs。具有磁性附件的IARPD比具有愈合帽的IARPD具有更好的患者总体满意度和PDA。结论OHRQoL,患者总体满意度,IARPD通过使用磁性附件的短植入物改善了PDA。
    Purpose Implant-assisted removable partial dentures (IARPDs) with short implants improve the oral functions of removable partial dentures (RPDs). This study aimed to compare the patient-reported outcomes of RPDs and IARPDs with short implants retained by magnetic attachments.Methods We recruited 30 participants with mandibular Kennedy Class I or II and distal extension defects of three or more teeth. RPDs, IARPDs with a healing cap, and IARPDs with a magnetic attachment were evaluated across stages using patient-reported outcomes. All participants completed questionnaires (oral health-related quality of life [OHRQoL], patient general satisfaction, and patient\'s denture assessment [PDA]) at each stage. The OHRQoL was evaluated using the Oral Health Impact Profile-J 54 (OHIP-J 54) score. The general patient satisfaction was evaluated using a 100 mm visual analog scale. The Wilcoxon signed-rank test and Bonferroni correction were used to evaluate differences between the groups (α=0.05).Results The OHRQoL of IARPDs was significantly higher than that of RPDs. IARPDs with a magnetic attachment had significantly better patient general satisfaction and PDA than IARPDs with a healing cap.Conclusions The OHRQoL, patient general satisfaction, and PDA were improved by IARPD with a short implant using a magnetic attachment.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    对于老年患者和双种植体覆盖义齿(2-IOD)佩戴者,改善咀嚼性能(MP)的适当加载方案仍不清楚。这项研究旨在比较由磁性附件保留的2-IOD的长期MP和立即加载(IL)和常规加载(CL)的最大咬合力。19例无牙患者被随机分配到IL组(n=10)或CL组(n=9)。在IL组中,植入物在插入的同一天装载,而CL组在插入后3个月加载。使用磁性附件将所有覆盖义齿保留到植入物上。MP,通过一块变色口香糖和软糖果冻测试来测量,和最大咬合力,使用咬合力测量装置测量,在基线和3-,4-,5年随访。
    在任何时间点,IL和CL组之间的MP和最大咬合力均未观察到显着差异。然而,在3年时间点,IL组的MP显著增高(P=0.036).最大咬合力显示与MP有显著相关性,在5年时都使用了变色口香糖和软糖果冻。
    经过长期观察,IL组和CL组之间MP和最大咬合力没有显着差异。然而,与植入前插入全口义齿相比,IL组MP在3年时显著改善。此外,5年时最大咬合力与MP显著相关。
    UMIN,UMIN000009889。2013年1月28日注册。
    The appropriate loading protocol to improve masticatory performance (MP) is still unclear in elderly patients and two-implant overdentures (2-IODs) wearers. This study aimed to compare the long-term MP and maximum occlusal force of immediate loading (IL) and conventional loading (CL) of 2-IODs retained by magnetic attachments. Nineteen edentulous patients were randomly assigned to either an IL (n=10) or CL group (n = 9). In the IL group, the implant was loaded on the same day as insertion, whereas it was loaded 3 months after insertion in the CL group. Magnetic attachments were used to retain all overdentures to the implants. MP, measured by a piece of color-changeable chewing gum and a gummy jelly test, and maximum occlusal force, measured using an occlusal force measuring device, were assessed in both groups at baseline and at 3-, 4-, and 5-year follow-ups.
    No significant differences were observed in the MP and the maximum occlusal force between the IL and CL groups at any time point. However, a significantly higher MP was observed at the 3-year time point in the IL group (P = 0.036). The maximum occlusal force revealed a significant correlation with MP, both with the color-changeable chewing gum and gummy jelly at 5 years.
    After long-term observation, no significant differences in MP and maximum occlusal force were observed between the IL and CL groups. However, compared to pre-implant insertion of the complete denture, the MP in the IL group significantly improved at 3 years. Furthermore, the maximum occlusal force was significantly correlated with MP at 5 years.
    UMIN, UMIN000009889 . Registered on 28 January 2013.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    OBJECTIVE: To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model.
    METHODS: The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05).
    RESULTS: The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P <.05), while there was no statistical difference between the normal and resorption group (P >.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P <.05).
    CONCLUSIONS: The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    This study compared peri-implant vertical bone loss, the periodontal index, prosthodontic maintenance requirements and oral health-related quality of life (OHQoL) of patients using mandibular implant-supported overdentures with 2 different attachment systems after an average of 5 years of use. Sixteen mandibular overdenture patients with magnet attachments (group 3), 24 with implant-supported mandibular overdentures with Locator attachments (group 2), and 25 conventional complete denture patients (group 1) were included in the study. The existing at least 5 years old dentures of all patients were evaluated for prosthodontic maintenance by the same prosthodontist and the patients were administered the oral health impact profile-14-Turkish version (OHIP-TR-14) questionnaire. Peri-implant tissue health was evaluated clinically in terms of plaque scores, bleeding scores, probing depth, and gingival index. Radiographic evaluation was performed in terms of peri-implant vertical bone loss. Radiographic evaluations were performed 5 years after overdenture insertion. There were no statistically significant differences between the groups in terms of total OHIP-TR-14 scores (P > .05). Although the average vertical bone resorption measured in group 2 at the end of 5 years was 1.38 mm, there was an average vertical bone loss of 1.45 mm in group 3, but this difference was not statistically significant (P > .05). Among the periodontal health indicators, there were no statistically significant differences in the mean values for periodontal indexes. According to results of the study, there were no differences in peri-implant vertical bone loss in groups 2 and 3, in periodontal health in mandibular overdentures with groups 2 and 3, or between total OHIP-TR-14 scores of patients in all groups.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:虽然磁性附着体经常用于覆盖义齿,据报道,吸引力可以通过磨损和腐蚀来降低。本研究的目的是通过研究应用于患者的磁性附着体的吸引力变化,建立有关使用磁性附着体的覆盖义齿的考虑和长期预后的临床基础。
    方法:在Dankook大学牙科医院使用磁性附着体进行覆盖义齿治疗的患者中,对2013年7月至2014年6月重新访问的20名受试者的61个磁性附着体的吸引力记录进行分析.牙科磁铁测试仪(爱知微智能有限公司,爱知,日本)用于测量。本研究中使用的磁性附件是MagfitIP-BFlat,MagfitDX400、MagfitDX600和MagfitDX800(爱知钢铁公司,爱知,日本)充满钕(NdFeB),稀土磁铁.
    结果:吸引力的减速比与施加附件的条件变量没有显着相关性,当维持时间较长时,则更高(P<.05,r=.361)。在使用超过9年的附件的受试者组中,吸引力的减少率明显高于9年内(P<0.05)。此外,总磁性附件的16.39%显示保持器或组件脱离。
    结论:无论条件变量如何,磁附着的吸引力都保持不变,并且随着维持时间的延长,减速比增加。对粘合材料的进一步研究,需要改进连接方法和设计以防止磁性连接的分离。
    OBJECTIVE: Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients.
    METHODS: Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet.
    RESULTS: Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly.
    CONCLUSIONS: Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    尽管面部修复治疗在头颈部癌症患者的康复中具有重要作用,其实施的延迟可能是不可避免的,防止患者接受及时的面部假体并恢复正常的社交生活。这里,我们介绍了一种制造临时面部假体的创新方法。使用3D建模系统,我们简化了制造方法,并使用钛重建板进行面部假体固位。患者在手术后立即接受面部假体,并且比常规面部假体治疗通常观察到的更早恢复正常的社交生活。
    Despite the important role of facial prosthetic treatment in the rehabilitation of head and neck cancer patients, delay in its implementation can be unavoidable, preventing patients from receiving a prompt facial prosthesis and resuming a normal social life. Here, we introduce an innovative method for the fabrication of an interim facial prosthesis. Using a 3D modeling system, we simplified the fabrication method and used a titanium reconstruction plate for facial prosthesis retention. The patient received the facial prosthesis immediately after surgery and resumed a normal social life earlier than is typically observed with conventional facial prosthetic treatment.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号