  • 文章类型: Journal Article
    目的:采用短种植体的种植体辅助可摘局部义齿(IARPDs)改善可摘局部义齿(RPDs)的口腔功能。这项研究旨在比较RPDs和IARPDs与磁性附件保留的短植入物的患者报告结果。方法我们招募了30名下颌KennedyI级或II级以及三颗或更多颗牙齿的远端延伸缺损的参与者。RPD,带有治疗帽的IARPD,使用患者报告的结局对带有磁性附件的IARPD和IARPD进行了分期评估.所有参与者完成问卷(口腔健康相关生活质量[OHRQoL],患者总体满意度,和患者义齿评估[PDA])在每个阶段。使用口腔健康影响概况-J54(OHIP-J54)评分评估OHRQoL。使用100mm视觉模拟量表评估患者的总体满意度。使用Wilcoxon符号秩检验和Bonferroni校正来评估组间差异(α=0.05)。结果IARPDs的OHRQoL明显高于RPDs。具有磁性附件的IARPD比具有愈合帽的IARPD具有更好的患者总体满意度和PDA。结论OHRQoL,患者总体满意度,IARPD通过使用磁性附件的短植入物改善了PDA。
    Purpose Implant-assisted removable partial dentures (IARPDs) with short implants improve the oral functions of removable partial dentures (RPDs). This study aimed to compare the patient-reported outcomes of RPDs and IARPDs with short implants retained by magnetic attachments.Methods We recruited 30 participants with mandibular Kennedy Class I or II and distal extension defects of three or more teeth. RPDs, IARPDs with a healing cap, and IARPDs with a magnetic attachment were evaluated across stages using patient-reported outcomes. All participants completed questionnaires (oral health-related quality of life [OHRQoL], patient general satisfaction, and patient\'s denture assessment [PDA]) at each stage. The OHRQoL was evaluated using the Oral Health Impact Profile-J 54 (OHIP-J 54) score. The general patient satisfaction was evaluated using a 100 mm visual analog scale. The Wilcoxon signed-rank test and Bonferroni correction were used to evaluate differences between the groups (α=0.05).Results The OHRQoL of IARPDs was significantly higher than that of RPDs. IARPDs with a magnetic attachment had significantly better patient general satisfaction and PDA than IARPDs with a healing cap.Conclusions The OHRQoL, patient general satisfaction, and PDA were improved by IARPD with a short implant using a magnetic attachment.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    对于老年患者和双种植体覆盖义齿(2-IOD)佩戴者,改善咀嚼性能(MP)的适当加载方案仍不清楚。这项研究旨在比较由磁性附件保留的2-IOD的长期MP和立即加载(IL)和常规加载(CL)的最大咬合力。19例无牙患者被随机分配到IL组(n=10)或CL组(n=9)。在IL组中,植入物在插入的同一天装载,而CL组在插入后3个月加载。使用磁性附件将所有覆盖义齿保留到植入物上。MP,通过一块变色口香糖和软糖果冻测试来测量,和最大咬合力,使用咬合力测量装置测量,在基线和3-,4-,5年随访。
    在任何时间点,IL和CL组之间的MP和最大咬合力均未观察到显着差异。然而,在3年时间点,IL组的MP显著增高(P=0.036).最大咬合力显示与MP有显著相关性,在5年时都使用了变色口香糖和软糖果冻。
    经过长期观察,IL组和CL组之间MP和最大咬合力没有显着差异。然而,与植入前插入全口义齿相比,IL组MP在3年时显著改善。此外,5年时最大咬合力与MP显著相关。
    UMIN,UMIN000009889。2013年1月28日注册。
    The appropriate loading protocol to improve masticatory performance (MP) is still unclear in elderly patients and two-implant overdentures (2-IODs) wearers. This study aimed to compare the long-term MP and maximum occlusal force of immediate loading (IL) and conventional loading (CL) of 2-IODs retained by magnetic attachments. Nineteen edentulous patients were randomly assigned to either an IL (n=10) or CL group (n = 9). In the IL group, the implant was loaded on the same day as insertion, whereas it was loaded 3 months after insertion in the CL group. Magnetic attachments were used to retain all overdentures to the implants. MP, measured by a piece of color-changeable chewing gum and a gummy jelly test, and maximum occlusal force, measured using an occlusal force measuring device, were assessed in both groups at baseline and at 3-, 4-, and 5-year follow-ups.
    No significant differences were observed in the MP and the maximum occlusal force between the IL and CL groups at any time point. However, a significantly higher MP was observed at the 3-year time point in the IL group (P = 0.036). The maximum occlusal force revealed a significant correlation with MP, both with the color-changeable chewing gum and gummy jelly at 5 years.
    After long-term observation, no significant differences in MP and maximum occlusal force were observed between the IL and CL groups. However, compared to pre-implant insertion of the complete denture, the MP in the IL group significantly improved at 3 years. Furthermore, the maximum occlusal force was significantly correlated with MP at 5 years.
    UMIN, UMIN000009889 . Registered on 28 January 2013.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    OBJECTIVE: To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model.
    METHODS: The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05).
    RESULTS: The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P <.05), while there was no statistical difference between the normal and resorption group (P >.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P <.05).
    CONCLUSIONS: The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    This study compared peri-implant vertical bone loss, the periodontal index, prosthodontic maintenance requirements and oral health-related quality of life (OHQoL) of patients using mandibular implant-supported overdentures with 2 different attachment systems after an average of 5 years of use. Sixteen mandibular overdenture patients with magnet attachments (group 3), 24 with implant-supported mandibular overdentures with Locator attachments (group 2), and 25 conventional complete denture patients (group 1) were included in the study. The existing at least 5 years old dentures of all patients were evaluated for prosthodontic maintenance by the same prosthodontist and the patients were administered the oral health impact profile-14-Turkish version (OHIP-TR-14) questionnaire. Peri-implant tissue health was evaluated clinically in terms of plaque scores, bleeding scores, probing depth, and gingival index. Radiographic evaluation was performed in terms of peri-implant vertical bone loss. Radiographic evaluations were performed 5 years after overdenture insertion. There were no statistically significant differences between the groups in terms of total OHIP-TR-14 scores (P > .05). Although the average vertical bone resorption measured in group 2 at the end of 5 years was 1.38 mm, there was an average vertical bone loss of 1.45 mm in group 3, but this difference was not statistically significant (P > .05). Among the periodontal health indicators, there were no statistically significant differences in the mean values for periodontal indexes. According to results of the study, there were no differences in peri-implant vertical bone loss in groups 2 and 3, in periodontal health in mandibular overdentures with groups 2 and 3, or between total OHIP-TR-14 scores of patients in all groups.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:虽然磁性附着体经常用于覆盖义齿,据报道,吸引力可以通过磨损和腐蚀来降低。本研究的目的是通过研究应用于患者的磁性附着体的吸引力变化,建立有关使用磁性附着体的覆盖义齿的考虑和长期预后的临床基础。
    方法:在Dankook大学牙科医院使用磁性附着体进行覆盖义齿治疗的患者中,对2013年7月至2014年6月重新访问的20名受试者的61个磁性附着体的吸引力记录进行分析.牙科磁铁测试仪(爱知微智能有限公司,爱知,日本)用于测量。本研究中使用的磁性附件是MagfitIP-BFlat,MagfitDX400、MagfitDX600和MagfitDX800(爱知钢铁公司,爱知,日本)充满钕(NdFeB),稀土磁铁.
    结果:吸引力的减速比与施加附件的条件变量没有显着相关性,当维持时间较长时,则更高(P<.05,r=.361)。在使用超过9年的附件的受试者组中,吸引力的减少率明显高于9年内(P<0.05)。此外,总磁性附件的16.39%显示保持器或组件脱离。
    结论:无论条件变量如何,磁附着的吸引力都保持不变,并且随着维持时间的延长,减速比增加。对粘合材料的进一步研究,需要改进连接方法和设计以防止磁性连接的分离。
    OBJECTIVE: Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients.
    METHODS: Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet.
    RESULTS: Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly.
    CONCLUSIONS: Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.