  • 文章类型: Case Reports
    结论:技术在定制巩膜晶状体和改善晶状体对准方面起着至关重要的作用,特别是在具有挑战性的巩膜形状。此外,远程安装技术允许验光师在全球范围内扩展他们的专业知识,使患者无需旅行费用即可获得定制镜片。
    目的:本研究的目的是记录1例圆锥角膜和明显巩膜复眼症患者在安装巩膜晶状体时遇到的困难。此外,该研究旨在展示利用先进技术成功实现的远程拟合。
    方法:一名被诊断为圆锥角膜的爱尔兰男性表现出高巩膜复光度。一般来说,圆锥角膜眼通常表现出与圆锥偏心和疾病严重程度相关的显着巩膜不对称性。巩膜晶状体不正确对准会导致巩膜形状的区域变化,透镜偏心,不适,和视觉障碍。的确,由于这些问题,以前的巩膜晶状体拟合不成功。Corneo巩膜轮廓术在爱尔兰获得,然后在意大利用于设计定制镜片,然后将其交付给爱尔兰患者的验光师。设计和交付的第一个镜头展示了出色的整体性能,无需调整。
    结论:本报告强调了角膜巩膜轮廓术对提高效率和减少晶状体重新订购和椅子时间的重要性,以及远程配件,以克服访问专用镜头配件的障碍。
    CONCLUSIONS: Technology plays a crucial role in customizing scleral lenses and improving lens alignment, especially in challenging scleral shapes. In addition, remote fitting technology allows optometrists to extend their expertise globally, empowering patients to access to customized lenses without travel expenses.
    OBJECTIVE: The objective of this study was to document the difficulties encountered in fitting a scleral lens in a patient with keratoconus and pronounced scleral toricity. In addition, the study aimed to present the successful remote fitting achieved by using advanced technology.
    METHODS: An Irish male patient diagnosed with keratoconus exhibited high scleral toricity. Generally, keratoconus eyes often exhibit significant scleral asymmetry associated with cone decentration and disease severity. Improperly aligned scleral lenses can lead to regional changes in scleral shape, lens decentration, discomfort, and visual disturbances. Indeed, previous scleral lens fits were unsuccessful because of these issues. Corneoscleral profilometry was acquired in Ireland and then used in Italy to design customized lenses, which were then delivered to the patient\'s optometrist in Ireland. The first lenses designed and delivered demonstrated excellent overall performance without requiring adjustments.
    CONCLUSIONS: This report highlights the importance of corneoscleral profilometry to increase efficiency and reduce lens reorders and chair time, and the remote fitting in overcoming barriers to accessing specialized lens fitting.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    在下肢假体的组成部分中,完美适应的假肢接受腔对于成功的康复过程至关重要。因此,开发更舒适的插座可以提高经股(TF)截肢者的生活质量。本病例报告的目的是通过评估插座刚度与使用者舒适度之间的关系及其对功能的影响来比较2个TF插座,以提高TF截肢者的生活质量。参与者收到2个不同的插座:(A)柔性Flixt®插座;(B)常规插座。每个插座他都用了90天,然后在步态实验室进行评估(运动学和动态分析),完成了假体评估问卷,并进行了计时和计时测试,6分钟三月测试(6MWT),10米步行测试,和截肢运动预测测试。分析结果后,获得最佳满意度的插座被分配给截肢者.综合措施表明,插座B在站立阶段既没有动力学参数也没有显着改变运动学参数。在假肢评估问卷结果中,插座A比插座B有更好的评级。6MWT,10米步行测试,截肢者机动预测器测试获得了相同的值,除了6MWT。此案例报告显示了使用灵活插座时参与者满意度提高的证据。研究还表明,这两个插座都非常有效。
    Among the components of lower limb prostheses, a perfectly adapted prosthetic socket is crucial to a successful rehabilitation process. Thus, developing a more comfortable socket could improve the quality of life for transfemoral (TF) amputees. The objective of this case report was to compare 2 TF sockets by evaluating the relationship between socket stiffness and user comfort and their influence on functionality to improve the quality of life of TF amputees. The participant received 2 different sockets: (A) flexible Flixt® socket; (B) conventional socket. He used each socket for 90 days, and after that was submitted to an evaluation at the Gait Laboratory (kinematic and dynamic analyses), completed the Prosthesis Evaluation Questionnaire, and performed Timed Up and Go test, 6-Minute March Test (6MWT), 10-Meter Walk Test, and Amputee Mobility Predictor test. After results were analyzed, the socket that obtained the best degree of satisfaction was assigned to the amputee participant. Combined measures showed that socket B does not considerably change the kinematic parameters neither dynamics parameters namely at stance phase. At Prosthesis Evaluation Questionnaire results, socket A had a better rating than socket B. The results of the Timed Up and Go test, 6MWT, 10-Meter Walk Test, and Amputee Mobility Predictor test obtained identical values, except for the 6MWT. This case report shows evidence of participant satisfaction improvement when using the flexible socket. The study also demonstrates that both sockets are quite effective.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    患有肢体缺失(截肢者)的妇女在怀孕期间有独特的需求增加。舒适,疼痛,活动呈指数级受损。质量的变化和重心的改变增加了跌倒的可能性,并损害了母亲和未出生婴儿的安全性。通过对一名36岁的右股截肢妇女进行2次单独怀孕,收集了主观和身体功能表现数据。怀孕期间的生理变化影响舒适,疼痛,和功能性能。应建立修复管理的临床实践指南,包括调整时间表等协议。专门的插座设计,以及整个怀孕过程中必要的成分变化。
    Women living with limb loss (amputees) have unique needs that increase during pregnancy. Comfort, pain, and activity are exponentially compromised. Changes in mass and altered center of gravity increase the likelihood of falls and compromise safety for the mother and unborn baby. Subjective and physical functional performance measures data was collected through 2 separate pregnancies on a 36-year-old woman with a right transfemoral amputation. Physiological changes during pregnancy effected comfort, pain, and functional performance. Clinical practice guidelines for prosthetic management should be established to include protocols such as adjustment schedules, specialized socket design, and necessary component changes throughout the course of pregnancy.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:评估晚期Terrien边缘变性(TMD)患者眼表生态系统假体置换(PROSE)治疗的结果。
    方法:这是一个回顾性病例系列,对晚期TMD患者进行了定制PROSE镜片的评估和配戴。数据收集了PROSE拟合细节,包括PROSE前后的视力(VA),裂隙灯的发现,和角膜断层扫描。
    结果:纳入4例患者的6只眼。所有患者在PROSE之前尝试了至少一种其他隐形眼镜(CL)模式。一些患者有角膜合并症,如假翼状胬肉和假球,这导致对以前的晶状体不耐受,在装配过程中需要额外考虑。有了PROSE,所有六只眼睛的VA均得到改善。结构性角膜合并症患者视力改善,comfort,和镜头公差与PROSE。两只眼睛有限制PROSE疗效的非角膜眼合并症。由于角膜缘干细胞疾病的进展,需要进行角膜缘干细胞移植,另一只眼睛停止了PROSE的佩戴。
    结论:PROSE治疗对于不能耐受一线治疗CL模式的晚期TMD患者来说,是改善视力和舒适度的有效选择。即使存在其他角膜合并症。
    OBJECTIVE: To assess outcomes of the Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) treatment in patients with advanced Terrien marginal degeneration (TMD).
    METHODS: This is a retrospective case series of patients with advanced TMD who were assessed and fit with customized PROSE lenses. Data were collected on PROSE fitting details including visual acuity (VA) before and after PROSE, slit-lamp findings, and corneal tomography scans.
    RESULTS: Six eyes in four patients were included. All patients attempted at least one other contact lens (CL) modality before PROSE. Some patients had corneal comorbidities such as pseudopterygium and pseudobleb that contributed to intolerance to previous lenses and warranted extra considerations in the fitting process. With PROSE, VA improved in all six eyes. Patients with structural corneal comorbidities achieved improved vision, comfort, and lens tolerance with PROSE. Two eyes had noncorneal ocular comorbidities that limited PROSE efficacy. Another eye discontinued PROSE wear because of limbal stem-cell disease progression necessitating a limbal stem-cell transplant.
    CONCLUSIONS: PROSE treatment can be an effective option to improve vision and comfort for patients with advanced TMD who are intolerant to first-line therapeutic CL modalities, even in the presence of other corneal comorbidities.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    UNASSIGNED: : Fitting a femoral prosthesis in a transfemoral amputee with a very short amputation stump is challenging. This case report aimed to introduce an effective and simple method that can preserve the residual limb length by the implantation of antibiotic-loaded bone cement for the treatment of a patient with femoral periprosthetic infection.
    UNASSIGNED: : A 30-year-old man who had osteosarcoma at the age of 13 years underwent transfemoral amputation 17 years after the initial surgery because of periprosthetic infection. Antibiotic-loaded bone cement was inserted into the infected bone marrow to control the residual infection and to preserve the stump length. The infection resolved, and the patient regained functional gait using a femoral prosthesis.
    UNASSIGNED: : This case report demonstrates the usefulness of antibiotic-loaded cement in preserving the length of residual limbs and for femoral prosthesis fitting after periprosthetic infection. Maintaining the residual bone length is crucial in amputees for the functional fitting of femoral prostheses. The use of antibiotic-loaded bone cement has potential as a simple and useful surgical option in amputees after periprosthetic infection.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Case Reports
    In times of unlimited availability of exchange lenses on the internet and in discount stores, the contact lens has increasingly become a lifestyle but also a disposable product. The targeted marketing of the contact lens as a mass product could only be realized because the fitting and application of the contact lenses are presented as very simple. The numbers of contact lens-induced complications, as well as the fact that the German market in particular has not seen any increase in the number of contact lens wearers in recent years (2015 to 2019), however, speak a different language.How to fit your patient correctly after a detailed explanation of the different types of contact lenses and their areas of application, how to instruct him or her on how to use them correctly and what risks the patient must be informed about is the subject of this 2nd part of \"The basics of practical contact lens fitting\". It also explains how to avoid complications that can occur when wearing contact lenses and how to advise and care for patients with contact lens intolerances.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    巩膜晶状体(SL)部分掩盖了高度像差的眼睛中的高阶像差(HOA)。虽然视敏度(VA)在SL佩戴期间可能显示出令人满意的定量临床结果,残差(未校正)HOA可能会使主观视觉质量目标得不到满足。
    这项研究的目的是报告一个病例,其中“20/20不快乐”的SL患者能够通过波前引导的SL达到视觉目标。
    一名40岁男性双侧圆锥角膜,具有SL的SnellenVA为20/20右眼(OD)20/16左眼(OS),报告了晚上的光晕和眩光以及知觉涂抹。当观察光点时,观察到“摩天轮”阴影OD和U形阴影操作系统。残余高阶均方根波前误差为0.49μmOD和0.39μmOS;通过视觉Strehl比率测量的视觉图像质量为0.067OD和0.092OS(瞳孔大小,4.00mm)。波前引导的SL将残余高阶均方根降低到0.19μmOD和0.25μmOS,VA提高到20/10OD和20/13OS,视觉Strehl提高到0.150OD和0.121OS。患者报告涂片减少,阴影,和夜视问题,满足他的视觉期望和目标。
    波前感测可量化较低的HOA和HOA,这会导致眼睛高度畸变的人的视觉不满,尽管有时达到典型的VA水平。随着针对这些残余像差以改善视觉图像质量的波前引导SL变得越来越可用,当常规临床选择不令人满意时,20/20不满意的患者应考虑这些患者.
    Scleral lenses (SLs) partially mask higher-order aberrations (HOAs) in highly aberrated eyes. Although visual acuity (VA) may show satisfactory quantitative clinical outcomes during SL wear, residual (uncorrected) HOAs can leave subjective visual quality goals unmet.
    The purpose of this study was to report a case where a \"20/20 unhappy\" patient with SLs was able to meet visual goals with wavefront-guided SLs.
    A 40-year-old male with bilateral keratoconus, whose Snellen VA with SLs was 20/20 right eye (OD) 20/16 left eye (OS), reported halos and glare at night and perceptual smearing. When viewing a point of light, a \"Ferris wheel\" shadowing was observed OD and a U-shaped shadowing OS. Residual higher-order root mean square wavefront error was 0.49 μm OD and 0.39 μm OS; visual image quality measured by visual Strehl ratio was 0.067 OD and 0.092 OS (pupil size, 4.00 mm). Wavefront-guided SLs reduced residual higher-order root mean square to 0.19 μm OD and 0.25 μm OS, VA improved to 20/10 OD and 20/13 OS, and visual Strehl improved to 0.150 OD and 0.121 OS. The patient reported reduced smearing, shadowing, and night vision concerns, meeting his visual expectations and goals.
    Wavefront sensing quantifies both lower and HOAs, which can cause visual dissatisfaction in individuals with highly aberrated eyes, despite sometimes reaching typical levels of VA. As wavefront-guided SLs targeting these residual aberrations to improve visual image quality become more available, they should be considered for 20/20 unhappy patients when conventional clinical options are unsatisfactory.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Case Reports
    Because the prognosis of corneal regrafting is worse than a primary graft, it is pertinent to recognize other clinical management options to postpone the need for surgical intervention. Scleral lenses are a viable option in achieving excellent vision and comfort for post-graft patients; however, close monitoring is vital to success.
    The purpose of this study was to report a case in which a post-graft keratoconus patient can be successfully fit and refit with scleral lenses as their corneal tissue changes shape with time. Ultimately, the goal for this patient was to delay the need for regrafting procedures.
    This case presents a 57-year-old patient who has undergone penetrating keratoplasty in both eyes secondary to keratoconus. His original corneal grafts were 15 years or older. Because of a history of graft rejection in the right eye, he had a regraft in 2004. The left eye has signs of early rejection. The patient has been a scleral lens wearer since 2008. Within the past 24 months, he has required lens adjustments and refits because his fragile corneal tissue has changed shape. Lens changes were indicated when he presented with complaints of fogging associated with redness and irritation. We continued to work closely with the patient\'s corneal ophthalmologist, who recommended we maximize scleral lens wear in lieu of a corneal regraft. Because of the change from an oblate to prolate cornea, fitting this patient in a scleral lens has been a challenging task.
    Scleral lenses are a viable option in post-graft patients who present with ectatic changes to their corneal tissue. This patient continues to see 20/20 in each eye and comfortably wears his lenses for up to 6 hours. By fitting this patient in a scleral lens, we have been able to avoid the need for a regraft and the possible negative outcomes that can be associated.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    Ceramic acetabular liner fracture is a rare complication and requires early revision surgery to avoid abrasive damaging of metal components by ceramic particles. Chromium-cobalt femoral head can be used in revision surgery if only fractured ceramic particles are completely removed because the abrasive effect of ceramic debris is more pronounced on metal head compared to ceramic head. In this article, we report a 50-year-old male patient of delayed acetabular liner fracture in which we used a ceramic head that is more resistant to residue ceramic particles. We assessed the patient by using computed tomography (CT) to locate the ceramic particles. By using CT imaging, we can detect which ceramic particles pose high morbidity risk for debridement.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    Global brachial plexopathies including multiple nerve root avulsions may result in complete upper limb paralysis despite surgical treatment. Bionic reconstruction, which includes the elective amputation of the functionless hand and its replacement with a mechatronic device, has been described for the transradial level. Here, we present for the first time that patients with global brachial plexus avulsion injuries and lack of biological shoulder and elbow function benefit from above-elbow amputation and prosthetic rehabilitation. Between 2012 and 2017, forty-five patients with global brachial plexus injuries approached our centre, of which nineteen (42.2%) were treated with bionic reconstruction. While fourteen patients were amputated at the transradial level, the entire upper limb was replaced with a prosthetic arm in a total of five patients. Global upper extremity function before and after bionic arm substitution was assessed using two objective hand function tests, the action research arm test (ARAT), and the Southampton hand assessment procedure (SHAP). Other outcome measures included the DASH questionnaire, VAS to assess deafferentation pain and the SF-36 health survey to evaluate changes in quality of life. Using a hybrid prosthetic arm mean ARAT scores improved from 0.6 ± 1.3 to 11.0 ± 6.7 (p = 0.042) and mean SHAP scores increased from 4.0 ± 3.7 to 13.8 ± 9.2 (p = 0.058). After prosthetic arm replacement mean DASH scores improved from 52.5 ± 9.4 to 31.2 ± 9.8 (p = 0.003). Deafferentation pain decreased from mean VAS 8.5 ± 1.0 to 6.7 ± 2.1 (p = 0.055), while the physical and mental component summary scale as part of the SF-36 health survey improved from 32.9 ± 6.4 to 40.4 ± 9.4 (p = 0.058) and 43.6 ± 8.9 to 57.3 ± 5.5 (p = 0.021), respectively. Bionic reconstruction can restore simple but robust arm and hand function in longstanding brachial plexus patients with lack of treatment alternatives.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

公众号