visual electrophysiology

视觉电生理学
  • 文章类型: Journal Article
    OBJECTIVE: To investigate the characteristics and objective assessment method of visual field defects caused by optic chiasm and its posterior visual pathway injury.
    METHODS: Typical cases of visual field defects caused by injuries to the optic chiasm, optic tracts, optic radiations, and visual cortex were selected. Visual field examinations, visual evoked potential (VEP) and multifocal visual evolved potential (mfVEP) measurements, craniocerebral CT/MRI, and retinal optical coherence tomography (OCT) were performed, respectively, and the aforementioned visual electrophysiological and neuroimaging indicators were analyzed comprehensively.
    RESULTS: The electrophysiological manifestations of visual field defects caused by optic chiasm injuries were bitemporal hemianopsia mfVEP abnormalities. The visual field defects caused by optic tract, optic radiation, and visual cortex injuries were all manifested homonymous hemianopsia mfVEP abnormalities contralateral to the lesion. Mild relative afferent pupil disorder (RAPD) and characteristic optic nerve atrophy were observed in hemianopsia patients with optic tract injuries, but not in patients with optic radiation or visual cortex injuries. Neuroimaging could provide morphological evidence of damages to the optic chiasm and its posterior visual pathway.
    CONCLUSIONS: Visual field defects caused by optic chiasm, optic tract, optic radiation, and visual cortex injuries have their respective characteristics. The combined application of mfVEP and static visual field measurements, in combination with neuroimaging, can maximize the assessment of the location and degree of visual pathway damage, providing an effective scheme for the identification of such injuries.
    目的: 探讨视交叉及其后部视路损伤所致视野缺损的特点及其客观评定方法。方法: 选择视交叉、视束、视放射及视皮质损伤所致视野缺损典型案例,分别进行视野、视觉诱发电位(visual evoked potential,VEP)、多焦视觉诱发电位(multifocal visual evoked potential,mfVEP)检查以及颅脑CT或MRI、视网膜光学相干断层扫描(optical coherence tomography,OCT),并对上述视觉电生理指标及神经影像学指标进行综合分析。结果: 视交叉损伤所致视野缺损的电生理学表现为双颞侧偏盲型mfVEP异常;视束、视放射及视皮质损伤所致视野缺损均表现为病变对侧的同向性偏盲型mfVEP异常。视束损伤出现偏盲眼轻度相对性传入性瞳孔障碍(relative afferent pupil disorder,RAPD)及特征性视神经萎缩表现,视放射、视皮质损伤则无此表现。神经影像学可为视交叉及其后部视路损伤提供形态学证据。结论: 视交叉、视束、视放射及视皮质损伤所致视野缺损具有各自特点,通过mfVEP视野与静态视野检查的联合应用,结合神经影像学检查,可最大程度地评价视路受损的部位和程度,为此类损伤的认定提供有效方案。.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    白化病描述了一组异质性的遗传决定的疾病,其特征是黑色素合成中断和一系列发育性眼部异常。眼皮肤白化病(OCA)常见的主要眼部特征,和眼白化病(OA)包括视力下降,屈光不正,中央凹发育不全,先天性眼球震颤,虹膜和眼底色素减退和视觉通路错误,但是临床症状各不相同,并且与其他病理有表型重叠。这项研究回顾了患病率,OCA和OA的遗传学和眼部表现,包括视交叉的异常发育。强调了视觉电生理学在检测交叉功能障碍和视觉通路错误中的作用,强调必须如何考虑视觉诱发电位(VEP)测试结果的年龄相关变化,才能进行准确诊断,并通过在遗传证实的病例中纳入新的VEP数据进一步说明。在怀疑视网膜和其他疾病的情况下考虑鉴别诊断,包括可能伪装成白化病的罕见综合征。
    Albinism describes a heterogeneous group of genetically determined disorders characterized by disrupted synthesis of melanin and a range of developmental ocular abnormalities. The main ocular features common to both oculocutaneous albinism (OCA), and ocular albinism (OA) include reduced visual acuity, refractive errors, foveal hypoplasia, congenital nystagmus, iris and fundus hypopigmentation and visual pathway misrouting, but clinical signs vary and there is phenotypic overlap with other pathologies. This study reviews the prevalence, genetics and ocular manifestations of OCA and OA, including abnormal development of the optic chiasm. The role of visual electrophysiology in the detection of chiasmal dysfunction and visual pathway misrouting is emphasized, highlighting how age-associated changes in visual evoked potential (VEP) test results must be considered to enable accurate diagnosis, and illustrated further by the inclusion of novel VEP data in genetically confirmed cases. Differential diagnosis is considered in the context of suspected retinal and other disorders, including rare syndromes that may masquerade as albinism.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    OBJECTIVE: To investigate how PM2.5 exposure affects the microstructure, metabolites or functions of the visual system.
    METHODS: C57BL/6J mice were randomly assigned to groups exposed to the filtered air (the control group) or the concentrated ambient PM2.5 (the PM2.5 group). Visual evoked potentials (VEP), electroretinograms (ERG), diffusion tensor imaging (DTI), proton magnetic resonance spectroscopy (1H-MRS) and resting-state functional MRI (rsfMRI) were performed. Parameters were obtained and compared between the two groups, including latencies and amplitudes of the P1 wave, N1 wave and P2 wave from VEP, latencies and amplitudes of the a wave and b wave from ERG, fractional anisotropy (FA), mean diffusion (MD), axial diffusivity (AD) and radial diffusivity (RD) from DTI, visual cortex (VC) metabolites from 1H-MRS, and regional homogeneity (ReHo) from rsfMRI.
    RESULTS: Compared with the values of the control group, the PM2.5 group showed a prolonged N1 latency (43.11 ± 7.94 ms vs. 38.75 ± 4.60 ms) and lowered P1 amplitude (5.62 ± 4.38 μV vs. 8.56 ± 5.92 μV) on VEP (all p < 0.05). On ERG, the amplitude of the a wave was lowered (- 91.39 ± 56.29 μV vs. - 138.68 ± 89.05 μV), the amplitude of the b wave was lowered (194.38 ± 126.27 μV vs. 284.72 ± 170.99 μV), and the latency of the b wave was prolonged (37.78 ± 10.72 ms vs. 33.01 ± 4.34 ms) than the values of the control group (all p < 0.05). DTI indicated FA increase in the bilateral piriform cortex (Pir), FA decrease in the bilateral somatosensory cortex (S) and the bilateral striatum (Stri), AD decrease in the bilateral VC, the right S and the bilateral Pir, MD decrease in the bilateral Pir, and RD decrease in the bilateral Pir in the PM2.5 mice (all p < 0.05, Alphasim corrected). 1H-MRS showed Glutamate (Glu) increase and Phosphocholine (PCh) increase in the VC of the PM2.5 group than those of the control group (PCh 1.63 ± 0.25 vs. 1.50 ± 0.25; PCh/total creatine(tCr) 0.19 ± 0.03 vs. 0.18 ± 0.03; Glu 10.46 ± 1.50 vs. 9.60 ± 1.19; Glu/tcr 1.23 ± 0.11 vs. 1.12 ± 0.11) (all p < 0.05). rsfMRI showed higher ReHo in the PM2.5 mice in the left superior colliculus, the left motor cortex, the hippocampus, the periaqueductal gray and the right mesencephalic reticular formation (all p < 0.01, AlphaSim corrected).
    CONCLUSIONS: This study revealed that PM2.5 exposure triggered visual dysfunction, and altered microstructure, metabolite and function in the retina and visual brain areas along the visual system.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    OBJECTIVE: Visual outcomes after cataract surgery in diabetic patients with retinal or visual pathway disease are difficult to predict as the fundus may be obscured, and assessment of visual potential is challenging. This study assessed the value of visual electrophysiology as a prognostic indicator of visual recovery in diabetic patients with cataract, prior to cataract surgery.
    METHODS: Forty-one diabetic patients (aged 52-80; 74 eyes) and 13 age-matched non-diabetic control patients (21 eyes) were examined prior to cataract surgery. Pre-surgical examinations included best-corrected visual acuity (BCVA), slit-lamp bio-microscopy, ISCEV-standard full-field electroretinography (ffERG), and flash visual evoked potential (flash VEP) testing. Electrophysiological assessments included quantification of the DA and LA ERG, oscillatory potentials (OPs; OP1, OP2, OP3, OP4) and flash VEP P1, P2, and P3 components. Post-operative BCVA was measured in all cases and the diabetic patients grouped according to the severity of visual acuity loss: mild (logMAR ≤ 0.1), moderate (0.1 < logMAR < 0.5), or severe (logMAR ≥ 0.5). A fourth group included those without diabetes. The pre-surgical electrophysiological data was compared between the four groups by analysis of variance.
    RESULTS: The severity of post-surgical visual acuity loss in the diabetic patients was classified as mild (N=22 eyes), moderate (N=31 eyes), or severe (N=21 eyes). In the group without diabetes, post-surgical visual impairment was classified as mild (N=21 eyes). The pre-operative DA 10.0 ERG a-wave amplitudes, DA 3.0 ERG OP2 amplitudes, and the LA 3.0 a- and b-wave amplitudes showed best significant differences among the four groups. The flash VEP did not show significant difference between groups.
    CONCLUSIONS: Electrophysiological assessment of diabetic patients with cataract can provide a useful measure of retinal function. Full-field ERG components, including the DA 10.0 ERG a-wave, DA 3.0 ERG OP2 component, and the LA 3.0 a- and b-wave amplitudes, are of prognostic value in predicting post-surgical visual acuity, and may inform the surgical management of cataract patients with diabetes.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    To investigate the magnitude and time course of pseudorandom ffERG during light adaptation.
    Ten healthy subjects (26 ± 10.1 years) underwent 20 min of dark adaptation, and then the ffERG was evoked by pseudorandom flash sequences (4 ms per flash, 3 cd.s/m2) driven by m-sequences (210-1 stimulus steps) using Veris Science software and a Ganzfeld dome over a constant field of light adaptation (30 cd/m2). The base period of the m-sequence was 50 ms. Each stimulation sequence lasting 40 s was repeated at 0, 5, 10, 15 and 20 min of light adaptation. Relative amplitude and latency (corrected by values found at 0 min) of the three components (N1, P1, and N2) of first-order (K1) and first slice of the second-order (K2.1) kernel at 5 time points were evaluated. An exponential model was fitted to the mean amplitude and latency data as a function of the light adaptation duration to estimate the time course (τ) of the light adaptation for each component. Repeated one-way ANOVA followed by Tukey post-test was applied to the amplitude and latency data, considering significant values of p < 0.05.
    Regarding the K1 ffERG, N1 K1, P1 K1, and N2 K1 presented an amplitude increase as a function of the light adaptation (N1 K1 τ value = 2.66 min ± 4.2; P1 K1 τ value = 2.69 min ± 2.10; and N2 K1 τ value = 3.49 min ± 2.96). P1 K1 and N2 K1 implicit time changed as a function of the light adaptation duration (P1 K1 τ value = 3.61 min ± 5.2; N2 K1 τ value = 3.25 min ± 4.8). N1 K1 had small implicit time changes during the light adaptation. All the K2,1 components also had nonsignificant changes in amplitude and implicit time during the light adaptation.
    Pseudorandom ffERGs showed different mechanisms of adaptation to retinal light. Our results suggest that K1 ffERG is generated by retinal mechanisms with intermediate- to long-term light adaptation, while K2.1 ffERG is generated by retinal mechanism with fast light adaptation course.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    The aim of the present study was to observe visual pathway changes on the contralateral side in optic nerve sheath meningioma (ONSM). The authors present a case report of a 43-year-old patient with OfNSM on the right side. A complex ophthalmic examination was performed, including an assessment of visual functions, an electrophysiology examination and functional and structural MRI examinations. Visual acuity of the right eye after ONSM remained with no light perception, while that of the left side was normal. The visual field of the left eye was normal as was colour perception. An electrophysiology examination using a pattern electroretinogram revealed low amplitude values in the right eye. In the left eye, the finding was at the lower limit of normal results. The pattern visual evoked potential exhibited a bilateral lesion with a larger decrease in response after stimulation of the right eye. The structural MRI revealed intraorbital atrophy of the optic nerve on the right side throughout the whole course, which was accompanied by atrophy of the right half of the optic chiasm. Functional magnetic resonance imaging revealed zero activity after stimulation of the right eye and decreased activity in the visual centre after stimulation of the left eye. The present study demonstrated that unilateral damage to the optic nerve in ONSM is accompanied by significant changes on the contralateral side of the optic pathway.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    The aim of this study was to investigate the use of inexpensive and easy-to-use hydrogel \"marble\" electrodes for the recording of electrical potentials of the human visual cortex using visual evoked potentials (VEPs) as example. Top hat-shaped holders for the marble electrodes were developed with an electrode cap to acquire the signals. In 12 healthy volunteers, we compared the VEPs obtained with conventional gold-cup electrodes to those obtained with marble electrodes. Checkerboards of two check sizes-0.8° and 0.25°-were presented. Despite the higher impedance of the marble electrodes, the line noise could be completely removed by averaging 64 single traces, and VEPs could be recorded. Linear mixed-effect models using electrode type, stimulus, and recording duration revealed a statistically significant effect of the electrode type on only VEP N75 peak latency (mean ± SEM: 1.0 ± 1.2 ms) and amplitude (mean ± SEM: 0.8 ± 0.9 µV) The mean amplitudes of the delta, theta, alpha, beta, and gamma frequency bands of marble electrodes were statistically significantly different and, on average, 25% higher than those of gold-cup electrodes. However, the mean amplitudes showed a statistically significant strong correlation (Pearson\'s r = 0.8). We therefore demonstrate the potential of the inexpensive and efficient hydrogel electrode to replace conventional gold-cup electrodes for the recording of VEPs and possibly other recordings from the human cortex.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model.
    Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model.
    Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD.
    Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Acupuncture therapy has a positive effect in the treatment of amblyopia. This article summarizes findings of the research on brain mechanisms underlying the regulatory effect of acupuncture on visual plasticity of amblyopia. In a multi-system and multi-level viewpoints, we elaborated brain mechanism underlying the regulatory effect of acupuncture on visual plasticity in amblyopia from the perspective of ultrastructure, plasticity, electrical activities, neural coding and visual microcirculation of the neurons of the visual cortex, and the targeting points from the visual center to the effector organ.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    The ISCEV standards and recommendations for electrophysiological recordings in ophthalmology define a set of protocols with stimulus parameters, acquisition settings, and recording conditions, to unify the data and enable comparability of results across centers. Up to now, however, there are no standards to define the storage and exchange of such electrophysiological recordings. The aim of this study was to develop an open standard data format for the exchange and storage of visual electrophysiological data (ElVisML).
    We first surveyed existing data formats for biomedical signals and examined their suitability for electrophysiological data in ophthalmology. We then compared the suitability of text-based and binary formats, as well as encoding in Extensible Markup Language (XML) and character/comma-separated values.
    The results of the methodological consideration led to the development of ElVisML with an XML-encoded text-based format. This allows referential integrity, extensibility, the storing of accompanying units, as well as ensuring confidentiality and integrity of the data. A visualization of ElVisML documents (ElVisWeb) has additionally been developed, which facilitates the exchange of recordings on mailing lists and allows open access to data along with published articles.
    The open data format ElVisML ensures the quality, validity, and integrity of electrophysiological data transmission and storage as well as providing manufacturer-independent access and long-term archiving in a future-proof format. Standardization of the format of such neurophysiology data would promote the development of new techniques and open software for the use of neurophysiological data in both clinic and research.