  • 文章类型: Journal Article
    177Lu可在给药后使用SPECT/CT成像。迄今为止,大多数工作都集中在使用后处理成像来测量正常器官和肿瘤剂量。我们旨在评估治疗后SPECT/CT对接受177Lu-前列腺特异性膜抗原(PSMA)放射性药物治疗(RPT)的患者管理的影响。方法:在这项回顾性研究中,122例患者在治疗后24小时接受PSMARPT和随后的SPECT/CT。我们确定了每个周期的定性反应,并回顾了患者图表,以评估治疗后SPECT/CT对患者管理的影响。患者管理的变化根据进展和反应分为变化,并记录了它们发生时的具体周期。还评估了患者管理中的其他变化。结果:在122例连续检查的患者中,42%-56%表现出稳定的疾病,而19%-39%的患者在整个治疗周期中对视觉评估有反应.总的来说,49%(n=60)的患者经历了管理方面的变化,其中57%(n=34)是由于进展,40%(n=24)是由于反应,3%(n=2)是由于其他变化。主要在周期2和4之后观察到由于疾病进展引起的变化。由于对RPT的反应而引起的变化主要发生在第3和第4周期之后。结论:在我们的中心,49%的患者经历了基于治疗后SPECT/CT的管理变化,这些变化大多发生在第2和第4周期。将治疗后SPECT/CT整合到常规PSMARPT方案中可以帮助患者管理。
    177Lu can be imaged after administration using SPECT/CT. Most work to date has focused on using posttreatment imaging to measure normal organ and tumor dose. We aimed to assess the impact of posttreatment SPECT/CT on the management of patients undergoing 177Lu-prostate-specific membrane antigen (PSMA) radiopharmaceutical therapy (RPT). Methods: In this retrospective study, 122 patients underwent PSMA RPT with subsequent SPECT/CT 24 h after treatment. We determined a qualitative response at each cycle and reviewed patient charts to assess the impact that posttreatment SPECT/CT had on patient management. Changes in patient management were classified as changes on the basis of progression and response, and specific cycles when they occurred were noted. Miscellaneous changes in patient management were also evaluated. Results: Among the 122 consecutive patients examined, 42%-56% exhibited stable disease, whereas 19%-39% of patients exhibited response on visual assessment across treatment cycles. In total, 49% (n = 60) of patients experienced changes in management, of which 57% (n = 34) were due to progression, 40% (n = 24) were due to response, and 3% (n = 2) were due to miscellaneous changes. Changes due to disease progression were observed mostly after cycles 2 and 4. Changes due to response to RPT occurred mostly after cycles 3 and 4. Conclusion: At our center, 49% of patients experienced changes in management based on posttreatment SPECT/CT, and most of these changes occurred at cycles 2 and 4. Integrating posttreatment SPECT/CT into routine PSMA RPT protocols can aid in patient management.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    磷脂酰肌醇蛋白聚糖-3(GPC3)在肝细胞癌和肝母细胞瘤中过表达,是重要的治疗靶标,但GPC3在肝癌中的生物学重要性尚不清楚。迄今为止,有有限的数据表征GPC3基因敲除(KO)在本质上表达这一靶标的肝癌中的生物学意义.这里,我们报告了GPC3-KO肝癌细胞系的发展和表征,并将其与亲本细胞系进行了比较。使用慢病毒介导的CRISPR/Cas9系统在HepG2和Hep3B肝癌细胞系中建立GPC3-KO变体。我们在体外和鼠异种移植模型中评估了GPC3缺乏对致癌特性的影响。通过RNAseq和westernblot检查由GPC3缺乏引起的下游细胞信号传导途径的变化。为了证实这些模型对GPC3靶向药物开发的有用性,我们评估了GPC3选择性抗体的靶标接合,GC33,与野生型(WT)和KO肝癌细胞系的皮下鼠异种移植物中的正电子发射锆89(89Zr)缀合。GPC3的缺失显著降低了肝癌细胞的增殖,迁移,和侵袭相比亲代细胞系。此外,GPC3-KO肝癌异种移植物的肿瘤生长明显慢于对照异种移植物.RNA测序分析还显示GPC3-KO导致与细胞周期调控相关的基因表达减少,入侵,和移民。具体来说,我们观察到AKT/NFκB/WNT信号通路中的组分以及与GPC3-KO调节细胞周期相关的分子的下调。相比之下,pMAPK/ERK1/2上调,提示适应性补偿反应。KO线表现出对ERK(GDC09994)的敏感性增加,而AKT(MK2206)抑制在WT细胞系中更有效。使用基于抗体的正电子发射断层扫描(免疫PET)成像,我们证实,89Zr-GC33仅在GPC3表达的异种移植物中积累,而在具有高肿瘤摄取和肿瘤与肝脏信号比的GPC3-KO异种移植物中没有积累。我们表明GPC3-KO肝癌细胞系表现出降低的致瘤性和改变的信号通路,包括与亲本系相比上调的pMAPK/ERK1/2。此外,我们使用GPC3靶向的免疫PET显像剂成功区分GPC3+和GPC3-肿瘤,证明了这些细胞系在促进GPC3选择性药物开发中的潜在效用。
    Glypican-3 (GPC3) is overexpressed in hepatocellular carcinomas and hepatoblastomas and represents an important therapeutic target but the biologic importance of GPC3 in liver cancer is unclear. To date, there are limited data characterizing the biological implications of GPC3 knockout (KO) in liver cancers that intrinsically express this target. Here, we report on the development and characterization of GPC3-KO liver cancer cell lines and compare to them to parental lines. GPC3-KO variants were established in HepG2 and Hep3B liver cancer cell lines using a lentivirus-mediated CRISPR/Cas9 system. We assessed the effects of GPC3 deficiency on oncogenic properties in vitro and in murine xenograft models. Downstream cellular signaling pathway changes induced by GPC3 deficiency were examined by RNAseq and western blot. To confirm the usefulness of the models for GPC3-targeted drug development, we evaluated the target engagement of a GPC3-selective antibody, GC33, conjugated to the positron-emitting zirconium-89 (89Zr) in subcutaneous murine xenografts of wild type (WT) and KO liver cancer cell lines. Deletion of GPC3 significantly reduced liver cancer cell proliferation, migration, and invasion compared to the parental cell lines. Additionally, the tumor growth of GPC3-KO liver cancer xenografts was significantly slower compared with control xenografts. RNA sequencing analysis also showed GPC3-KO resulted in a reduction in the expression of genes associated with cell cycle regulation, invasion, and migration. Specifically, we observed the downregulation of components in the AKT/NFκB/WNT signaling pathways and of molecules related to cell cycle regulation with GPC3-KO. In contrast, pMAPK/ERK1/2 was upregulated, suggesting an adaptive compensatory response. KO lines demonstrated increased sensitivity to ERK (GDC09994), while AKT (MK2206) inhibition was more effective in WT lines. Using antibody-based positron emission tomography (immunoPET) imaging, we confirmed that 89Zr-GC33 accumulated exclusively in GPC3-expression xenografts but not in GPC3-KO xenografts with high tumor uptake and tumor-to-liver signal ratio. We show that GPC3-KO liver cancer cell lines exhibit decreased tumorigenicity and altered signaling pathways, including upregulated pMAPK/ERK1/2, compared to parental lines. Furthermore, we successfully distinguished between GPC3+ and GPC3- tumors using the GPC3-targeted immunoPET imaging agent, demonstrating the potential utility of these cell lines in facilitating GPC3-selective drug development.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    锑-119(119Sb)有望用于放射性药物治疗(RPT),发射短程俄歇和转换电子,可以在细胞水平上传递细胞毒性辐射。虽然理论上它有很高的前景,实验验证对于119Sb的体内应用是必要的。当前的119Sb生产和分离方法在放射性药物合成中面临鲁棒性和相容性挑战。螯合剂开发的有限进展阻碍了119Sb的靶向实验。这篇综述汇编了有关毒理学的文献,Sb的生物分布和氧化还原性质,连同现有的Sb配合物,评估它们对放射性药物的适用性。由于Sb(III)在体内的稳定性和缺乏骨骼摄取,因此被认为是放射性药物加工的首选氧化态。虽然可以实现具有硬和软供体原子的Sb络合物,Sb硫醇络合物提供增强的稳定性和与期望的Sb(III)氧化态的相容性。对于119Sb在RPT中的应用,科学家需要在同位素生产领域做出发现和进步,和放射性金属螯合。这篇综述旨在指导未来的研究,以利用119Sb在RPT中的治疗潜力。
    Antimony-119 (119Sb) holds promise for radiopharmaceutical therapy (RPT), emitting short-range Auger and conversion electrons that can deliver cytotoxic radiation on a cellular level. While it has high promise theoretically, experimental validation is necessary for 119Sb in vivo applications. Current 119Sb production and separation methods face robustness and compatibility challenges in radiopharmaceutical synthesis. Limited progress in chelator development hampers targeted experiments with 119Sb. This review compiles literature on the toxicological, biodistribution and redox properties of Sb, along with existing Sb complexes, evaluating their suitability for radiopharmaceuticals. Sb(III) is suggested as the preferred oxidation state for radiopharmaceutical elaboration due to its stability in vivo and lack of skeletal uptake. While Sb complexes with both hard and soft donor atoms can be achieved, Sb thiol complexes offer enhanced stability and compatibility with the desired Sb(III) oxidation state. For 119Sb to find application in RPT, scientists need to make discoveries and advancements in the areas of isotope production, and radiometal chelation. This review aims to guide future research towards harnessing the therapeutic potential of 119Sb in RPT.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    基于图像的剂量测定引导的放射性药物治疗具有通过限制对风险器官的毒性并最大化治疗效果来个性化治疗的潜力。核医学和分子成像协会的177Lu剂量测定挑战包括5项任务,评估剂量测定工作流程的变异性。第五个任务调查了与最后一步相关的可变性,剂量转换,本研究所基于的剂量测定工作流程。方法:由2名医学物理学家使用不同的软件评估参考变异性,方法,以及挑战中提供的输入分割格式和时间点的所有可能组合。计算了参与者提交的全球吸收剂量值的一般描述性统计,变异性是用四分位数离散系数测量的。结果:对于肝脏,其中包括高摄取的病变,变异高达36%。基线分析显示,肝脏吸收剂量结果的变异性为29%,数据集包括和排除的病变进行分组,这表明正常肝脏病变治疗方式的变化是变异性的重要来源。对于其他器官和病变,变异性在7%以内,独立于使用的软件,除了局部沉积方法。结论:剂量测定方法或软件的选择对剂量估计的总体变异性有很小的贡献。
    Image-based dosimetry-guided radiopharmaceutical therapy has the potential to personalize treatment by limiting toxicity to organs at risk and maximizing the therapeutic effect. The 177Lu dosimetry challenge of the Society of Nuclear Medicine and Molecular Imaging consisted of 5 tasks assessing the variability in the dosimetry workflow. The fifth task investigated the variability associated with the last step, dose conversion, of the dosimetry workflow on which this study is based. Methods: Reference variability was assessed by 2 medical physicists using different software, methods, and all possible combinations of input segmentation formats and time points as provided in the challenge. General descriptive statistics for absorbed dose values from the global submissions from participants were calculated, and variability was measured using the quartile coefficient of dispersion. Results: For the liver, which included lesions with high uptake, variabilities of up to 36% were found. The baseline analysis showed a variability of 29% in absorbed dose results for the liver from datasets where lesions included and excluded were grouped, indicating that variation in how lesions in normal liver were treated was a significant source of variability. For other organs and lesions, variability was within 7%, independently of software used except for the local deposition method. Conclusion: The choice of dosimetry method or software had a small contribution to the overall variability of dose estimates.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    内部剂量测定评估从体内放射性核素沉积在组织中的辐射能量的量以及时空分布。历史上,核医学主要是诊断专业,隐含地执行的风险收益分析很简单,相对较低的给药活动可产生重要的诊断信息,其益处远远超过与随之而来的正常组织辐射剂量相关的任何潜在风险。尽管在这种情况下基于解剖模型和人口平均动力学的剂量估计可能与个体患者的实际正常器官剂量有很大偏差,巨大的收益-风险比对于任何这样的不准确都是非常宽容的。正是在这种情况下,MIRD模式最初是在这种情况下开发的,并得到了广泛的应用。MIRD模式,由核医学和分子影像学会MIRD委员会创建和维护,包括符号,术语,数学公式,和用于计算来自给予患者的放射性药物的组织辐射剂量的参考数据。然而,随着新放射性药物的不断发展和此类药物的治疗应用日益增多,核医学中的内部剂量学和MIRD模式继续发展-从人口平均和器官水平到患者特异性和下器官水平,再到体素水平到细胞水平的剂量估计。本文将回顾基本的MIRD模式,相关数量和单位,参考解剖模型,以及它对小规模和患者特异性剂量学的适应性。
    Internal dosimetry evaluates the amount and spatial and temporal distributions of radiation energy deposited in tissue from radionuclides within the body. Historically, nuclear medicine had been largely a diagnostic specialty, and the implicitly performed risk-benefit analyses have been straightforward, with relatively low administered activities yielding important diagnostic information whose benefit far outweighs any potential risk associated with the attendant normal-tissue radiation doses. Although dose estimates based on anatomic models and population-average kinetics in this setting may deviate rather significantly from the actual normal-organ doses for individual patients, the large benefit-to-risk ratios are very forgiving of any such inaccuracies. It is in this context that the MIRD schema was originally developed and has been largely applied. The MIRD schema, created and maintained by the MIRD committee of the Society of Nuclear Medicine and Molecular Imaging, comprises the notation, terminology, mathematic formulas, and reference data for calculating tissue radiation doses from radiopharmaceuticals administered to patients. However, with the ongoing development of new radiopharmaceuticals and the increasing therapeutic application of such agents, internal dosimetry in nuclear medicine and the MIRD schema continue to evolve-from population-average and organ-level to patient-specific and suborgan to voxel-level to cell-level dose estimation. This article will review the basic MIRD schema, relevant quantities and units, reference anatomic models, and its adaptation to small-scale and patient-specific dosimetry.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:治疗计划通过治疗药物的诊断维度提供了预测RPT吸收剂量的见解,具有个性化辐射剂量以增强治疗效果的潜力。然而,现有的研究侧重于从诊断数据中进行剂量预测,通常依赖于器官水平的估计,忽略器官内的变化。本研究旨在表征器官内治疗异质性,并利用人工智能技术对其进行定位,即基于治疗前PET预测逐体素吸收剂量图。
    方法:回顾性纳入23例接受[177Lu]Lu-PSMAI&TRPT治疗的转移性去势抵抗性前列腺癌患者。选择具有治疗前PET成像和至少3个治疗后SPECT/CT成像的48个治疗周期。比较肾脏的PET示踪剂和RPT剂量的分布,肝脏和脾脏,表征器官内异质性差异。进行药代动力学模拟以增强对相关性的理解。探索了两种用于治疗前逐体素剂量测定预测的策略:(1)器官剂量引导的直接投影;(2)基于深度学习(DL)的分布预测。物理指标,剂量体积直方图(DVH)分析,和身份图被用来研究预测的吸收剂量图。
    结果:PET成像和剂量图之间出现了不一致的器官内模式,肾脏中存在中度相关性(r=0.77),肝脏(r=0.5),脾(r=0.58)(P<0.025)。模拟结果表明,器官内药代动力学异质性可能解释了这种不一致性。基于DL的方法实现了较低的平均按体素归一化均方根误差为0.79±0.27%,关于地面真相剂量图,优于器官剂量引导投影(1.11±0.57%)(P<0.05)。DVH分析显示了良好的预测准确性(肾脏的R2=0.92)。DL模型改善了同一性图中拟合线的平均斜率(肝脏为199%),与器官剂量方法的理论最佳结果相比。
    结论:我们的研究结果表明,药物动力学的器官内异质性可能会使治疗前剂量学预测复杂化。DL有可能弥合这一差距,用于逐体素异质剂量图的治疗前预测。
    OBJECTIVE: Treatment planning through the diagnostic dimension of theranostics provides insights into predicting the absorbed dose of RPT, with the potential to individualize radiation doses for enhancing treatment efficacy. However, existing studies focusing on dose prediction from diagnostic data often rely on organ-level estimations, overlooking intra-organ variations. This study aims to characterize the intra-organ theranostic heterogeneity and utilize artificial intelligence techniques to localize them, i.e. to predict voxel-wise absorbed dose map based on pre-therapy PET.
    METHODS: 23 patients with metastatic castration-resistant prostate cancer treated with [177Lu]Lu-PSMA I&T RPT were retrospectively included. 48 treatment cycles with pre-treatment PET imaging and at least 3 post-therapeutic SPECT/CT imaging were selected. The distribution of PET tracer and RPT dose was compared for kidney, liver and spleen, characterizing intra-organ heterogeneity differences. Pharmacokinetic simulations were performed to enhance the understanding of the correlation. Two strategies were explored for pre-therapy voxel-wise dosimetry prediction: (1) organ-dose guided direct projection; (2) deep learning (DL)-based distribution prediction. Physical metrics, dose volume histogram (DVH) analysis, and identity plots were applied to investigate the predicted absorbed dose map.
    RESULTS: Inconsistent intra-organ patterns emerged between PET imaging and dose map, with moderate correlations existing in the kidney (r = 0.77), liver (r = 0.5), and spleen (r = 0.58) (P < 0.025). Simulation results indicated the intra-organ pharmacokinetic heterogeneity might explain this inconsistency. The DL-based method achieved a lower average voxel-wise normalized root mean squared error of 0.79 ± 0.27%, regarding to ground-truth dose map, outperforming the organ-dose guided projection (1.11 ± 0.57%) (P < 0.05). DVH analysis demonstrated good prediction accuracy (R2 = 0.92 for kidney). The DL model improved the mean slope of fitting lines in identity plots (199% for liver), when compared to the theoretical optimal results of the organ-dose approach.
    CONCLUSIONS: Our results demonstrated the intra-organ heterogeneity of pharmacokinetics may complicate pre-therapy dosimetry prediction. DL has the potential to bridge this gap for pre-therapy prediction of voxel-wise heterogeneous dose map.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    了解177Lu-PSMA-617放射性药物疗法(RPT)中病变吸收剂量与肿瘤反应之间的关系仍然很复杂。我们旨在研究基线病变吸收剂量是否可以预测基于病变的反应,并探讨病变吸收剂量与前列腺特异性抗原(PSA)反应之间的联系。方法:在这项回顾性研究中,我们评估了50例335个指标病变的患者进行177Lu-PSMA-617RPT,在第1和第2周期后24小时对SPECT/CT进行了剂量学分析。首先,我们确定了每位患者的指标病变,并测量了基于病变的吸收剂量.在第2周期之后计算基于损伤的反应。此外,还计算了第2周期后的PSA50反应(从基线PSA下降50%)。在第1周期和第2周期,对平均和最大吸收剂量和前列腺特异性膜抗原(PSMA)体积强度乘积(VIP-PSMA)的相应反应称为SPECTmean,SPECTmaximum,和SPECTVIP-PSMA,分别。结果:在检查的50例患者中,46%的人在周期2后取得了PSA50反响。在335个指标病变中,58%是骨性的,32%是淋巴结,10%为软组织转移灶。PSA反应者的SPECT病变反应高于无反应者(SPECTmean反应为46.8%±26.1%与26.2%±24.5%,P=0.007;SPECTT最大响应为45%±25.1%vs.19%±27.0%,P=0.001;SPECTVIP-PSMA反应49.2%±30.3%vs.14%±34.7%,P=0.0005)。PSA反应与SPECTVIP-PSMA反应之间存在相关性(R2=0.40,P<0.0001)。在24小时单次时间点测量的基线吸收剂量与基于SPECT病变的反应之间存在有限的关系(对于平均和最大吸收剂量,R2=0.05,P=0.001,R2=0.03,P=0.007,分别)。结论:在这项回顾性研究中,基于病变的定量反应与患者水平PSA反应相关。我们观察到基线吸收剂量和基于病变的反应之间的有限关系。反应中的大多数差异仍然不能仅由基线吸收剂量来解释。在24小时的单个时间点建立RPT的剂量-反应关系存在一些局限性。
    Understanding the relationship between lesion-absorbed dose and tumor response in 177Lu-PSMA-617 radiopharmaceutical therapies (RPTs) remains complex. We aimed to investigate whether baseline lesion-absorbed dose can predict lesion-based responses and to explore the connection between lesion-absorbed dose and prostate-specific antigen (PSA) response. Methods: In this retrospective study, we evaluated 50 patients with 335 index lesions undergoing 177Lu-PSMA-617 RPT, who had dosimetry analysis performed on SPECT/CT at 24 h after cycles 1 and 2. First, we identified the index lesions for each patient and measured the lesion-based absorbed doses. Lesion-based response was calculated after cycle 2. Additionally, PSA50 response (a decline of 50% from baseline PSA) after cycle 2 was also calculated. The respective responses for mean and maximum absorbed doses and prostate-specific membrane antigen (PSMA) volumetric intensity product (VIP-PSMA) at cycles 1 and 2 were termed SPECTmean, SPECTmaximum, and SPECTVIP-PSMA, respectively. Results: Of the 50 patients reviewed, 46% achieved a PSA50 response after cycle 2. Of the 335 index lesions, 58% were osseous, 32% were lymph nodes, and 10% were soft-tissue metastatic lesions. The SPECT lesion-based responses were higher in PSA responders than in nonresponders (SPECTmean response of 46.8% ± 26.1% vs. 26.2% ± 24.5%, P = 0.007; SPECTmaximum response of 45% ± 25.1% vs. 19% ± 27.0%, P = 0.001; SPECTVIP-PSMA response of 49.2% ± 30.3% vs. 14% ± 34.7%, P = 0.0005). An association was observed between PSA response and SPECTVIP-PSMA response (R 2 = 0.40 and P < 0.0001). A limited relationship was found between baseline absorbed dose measured with a 24-h single time point and SPECT lesion-based response (R 2 = 0.05, P = 0.001, and R 2 = 0.03, P = 0.007, for mean and maximum absorbed doses, respectively). Conclusion: In this retrospective study, quantitative lesion-based response correlated with patient-level PSA response. We observed a limited relationship between baseline absorbed dose and lesion-based responses. Most of the variance in response remains unexplained solely by baseline absorbed dose. Establishment of a dose-response relationship in RPT with a single time point at 24 h presented some limitations.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:这项工作介绍了一种使用普通剂量计对溶液中的β发射放射性核素进行主动和被动剂量测定的新颖方法。将测量结果与来自蒙特卡洛(MC)模拟的吸收剂量对水(Dw)的估计进行比较。我们提出了一种获得水吸收剂量的方法,用剂量计测量,使用定制的SPECT/CT兼容体模验证基于蒙特卡罗的吸收剂量对水的估计值。 方法:圆柱形,丙烯酸SPECT/CT兼容的体模能够容纳IBAEFD二极管,IBARAZOR二极管,ExradinA20-375平行板离子室,未层压的EBT3薄膜,和薄的TLD100微立方体的目的是测量从常见的β-发射放射性药物治疗剂的溶液中对水的吸收剂量。体模配备了可移动的探测器插件,允许多种配置,并设计用于验证基于图像的吸收剂量估计与探测器测量。在延长的测量间隔内进行两个131I实验和一个177Lu实验,起始活性约为150-350MBq。使用EGSnrc2019中的egs_chorter用户代码将测量数据与蒙特卡罗模拟进行了比较。 主要结果:所有剂量计观测到的测量值和MC预测值在k=1不确定度内一致,在第二个131I实验期间,除了IBARAZOR二极管和A20-375离子室。尽管达成了协议,测量值通常比预测值低5-15%。相对于其他形式的放射治疗,k=1处的不确定性仍然很大(5-30%,取决于剂量计)。 重要意义:尽管不确定性很大,对于在MC预测的Dw的验证中使用基于剂量计的RPT测量,测量和模拟吸收剂量之间的总体一致性是有希望的. .
    Objective. This work introduces a novel approach to performing active and passive dosimetry for beta-emitting radionuclides in solution using common dosimeters. The measurements are compared to absorbed dose to water (Dw) estimates from Monte Carlo (MC) simulations. We present a method for obtaining absorbed dose to water, measured with dosimeters, from beta-emitting radiopharmaceutical agents using a custom SPECT/CT compatible phantom for validation of Monte Carlo based absorbed dose to water estimates.Approach. A cylindrical, acrylic SPECT/CT compatible phantom capable of housing an IBA EFD diode, Exradin A20-375 parallel plate ion chamber, unlaminated EBT3 film, and thin TLD100 microcubes was constructed for the purpose of measuring absorbed dose to water from solutions of common beta-emitting radiopharmaceutical therapy agents. The phantom is equipped with removable detector inserts that allow for multiple configurations and is designed to be used for validation of image-based absorbed dose estimates with detector measurements. Two experiments with131I and one experiment with177Lu were conducted over extended measurement intervals with starting activities of approximately 150-350 MBq. Measurement data was compared to Monte Carlo simulations using the egs_chamber user code in EGSnrc 2019.Main results. Agreement withink= 1 uncertainty between measured and MC predictedDwwas observed for all dosimeters, except the A20-375 ion chamber during the second131I experiment. Despite the agreement, the measured values were generally lower than predicted values by 5%-15%. The uncertainties atk = 1 remain large (5%-30% depending on the dosimeter) relative to other forms of radiation therapy.Significance. Despite high uncertainties, the overall agreement between measured and simulated absorbed doses is promising for the use of dosimeter-based RPT measurements in the validation of MC predictedDw.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    前列腺特异性膜抗原成像(RECIP)1.0中的反应评估标准是基于证据的框架,用于使用前列腺特异性膜抗原(PSMA)PET/CT评估转移性前列腺癌的治疗效果。本研究旨在通过RECIP1.0评估临时PSMAPET/CT与放射性药物治疗后的短期结果的关联。方法:这项多中心回顾性研究包括转移性去势抵抗性前列腺癌患者,这些患者在3个学术中心接受了[177Lu]Lu-PSMA放射性药物治疗,并在基线和12周时接受了PSMAPET/CT。由5位读者评估PSMAPET/CT图像对的视觉RECIP1.0。通过Kaplan-Meier分析,主要结果是RECIP与前列腺特异性抗原无进展生存期(PSA-PFS)的关联。结果:总的来说,287名筛查患者中有124名符合纳入标准,0(0%),29(23%),54(44%),124名完全缓解的患者中有41名(33%),部分响应,疾病稳定,或进行性疾病(PD)分别通过视觉RECIP1.0。视觉RECIPPD患者的PSA-PFS明显短于RECIP疾病稳定或RECIP部分反应患者(2.6vs.6.4vs.8.4mo;P<0.001)。RECIPPD患者与非RECIPPD患者的PSA-PFS中位数为2.6对7.2mo(风险比,13.0;95%CI,7.0-24.1;P<0.001)。结论:[177Lu]Lu-PSMA2个周期后通过RECIP1.0进行PSMAPET/CT可预测PSA-PFS。通过RECIP1.0的PSMAPET/CT可用于前列腺癌的早期阶段,以评估药物疗效并预测无进展生存期。
    Response Evaluation Criteria in Prostate-Specific Membrane Antigen Imaging (RECIP) 1.0 is an evidence-based framework to evaluate therapeutic efficacy in metastatic prostate cancer using prostate-specific membrane antigen (PSMA) PET/CT. This study aimed to evaluate the associations of interim PSMA PET/CT by RECIP 1.0 with short-term outcome after radiopharmaceutical treatment. Methods: This multicenter retrospective study included patients with metastatic castration-resistant prostate cancer who underwent [177Lu]Lu-PSMA radiopharmaceutical therapy at 3 academic centers and received PSMA PET/CT at baseline and at 12 wk. Pairs of PSMA PET/CT images were assessed by 5 readers for visual RECIP 1.0. The primary outcome was the association of RECIP with prostate-specific antigen progression-free survival (PSA-PFS) by Kaplan-Meier analysis. Results: In total, 124 of 287 screened patients met the inclusion criteria, with 0 (0%), 29 (23%), 54 (44%), and 41 (33%) of those 124 patients having complete response, partial response, stable disease, or progressive disease (PD) by visual RECIP 1.0, respectively. Patients with visual RECIP PD had a significantly shorter PSA-PFS than those with RECIP stable disease or with RECIP partial response (2.6 vs. 6.4 vs. 8.4 mo; P < 0.001). The median PSA-PFS among patients with RECIP PD versus those with non-RECIP PD was 2.6 versus 7.2 mo (hazard ratio, 13.0; 95% CI, 7.0-24.1; P < 0.001). Conclusion: PSMA PET/CT by RECIP 1.0 after 2 cycles of [177Lu]Lu-PSMA is prognostic for PSA-PFS. PSMA PET/CT by RECIP 1.0 may be used in earlier stages of prostate cancer to evaluate drug efficacy and to predict progression-free survival.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    计算模型产生了对实验方法未完全阐明的生物相互作用的有价值的见解。这项研究调查了一种创新的时空模型,用于模拟使用177Lu-PSMA的放射性药物治疗(RPT)的受控释放和分散,前列腺特异性膜抗原(PSMA)靶向放射性药物,通过双重释放可植入递送系统在实体瘤内。抗癌剂的局部递送提出了减轻不良反应同时优化治疗结果的战略方法。
    本研究评估了影响RPT疗效的各种因素,包括缺氧区域延伸,结合亲和力,和初始药物剂量,采用一种新颖的三维计算模型。分析测量了这些因素对肿瘤微环境中放射性药剂浓度的影响。此外,探讨了肿瘤和周围组织内的时空放射性药物分布。
    分析表明,与周围正常组织相比,肿瘤区域内的曲线下总浓度面积显著更高。此外,与放射源相比,药物分布表现出明显的优异疗效。此外,延长缺氧区域的低微血管密度增强了药物的可用性,促进改善与PSMA受体的结合并增强治疗效果。解离常数(KD)的降低导致提高的结合亲和力和增加的内化药物浓度。初始放射性(7.1×107、7.1×108和7.1×109[Bq])的评估表明,7.1×108[Bq]的活性在消除肿瘤细胞和对正常组织的最小影响之间提供了有利的平衡。
    这些发现强调了局部放射性药物输送策略的潜力,并强调了释放的药物相对于放射源(植入物)在有效肿瘤治疗中的关键作用。减少药物与微血管网络的接近度并增强其在肿瘤内的分布促进更有效的治疗结果。该研究为未来的实验研究和临床试验提供了宝贵的见解,旨在完善药物治疗方案,最大限度地减少对体内试验的依赖。
    UNASSIGNED: Computational models yield valuable insights into biological interactions not fully elucidated by experimental approaches. This study investigates an innovative spatiotemporal model for simulating the controlled release and dispersion of radiopharmaceutical therapy (RPT) using 177Lu-PSMA, a prostate-specific membrane antigen (PSMA) targeted radiopharmaceutical, within solid tumors via a dual-release implantable delivery system. Local delivery of anticancer agents presents a strategic approach to mitigate adverse effects while optimizing therapeutic outcomes.
    UNASSIGNED: This study evaluates various factors impacting RPT efficacy, including hypoxia region extension, binding affinity, and initial drug dosage, employing a novel 3-dimensional computational model. Analysis gauges the influence of these factors on radiopharmaceutical agent concentration within the tumor microenvironment. Furthermore, spatial and temporal radiopharmaceutical distribution within both the tumor and surrounding tissue is explored.
    UNASSIGNED: Analysis indicates a significantly higher total concentration area under the curve within the tumor region compared to surrounding normal tissue. Moreover, drug distribution exhibits notably superior efficacy compared to the radiation source. Additionally, low microvascular density in extended hypoxia regions enhances drug availability, facilitating improved binding to PSMA receptors and enhancing therapeutic effectiveness. Reductions in the dissociation constant (KD) lead to heightened binding affinity and increased internalized drug concentration. Evaluation of initial radioactivities (7.1×107, 7.1×108, and 7.1×109 [Bq]) indicates that an activity of 7.1×108 [Bq] offers a favorable balance between tumor cell elimination and minimal impact on normal tissues.
    UNASSIGNED: These findings underscore the potential of localized radiopharmaceutical delivery strategies and emphasize the crucial role of released drugs relative to the radiation source (implant) in effective tumor treatment. Decreasing the proximity of the drug to the microvascular network and enhancing its distribution within the tumor promote a more effective therapeutic outcome. The study furnishes valuable insights for future experimental investigations and clinical trials, aiming to refine medication protocols and minimize reliance on in vivo testing.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

公众号