  • 文章类型: Journal Article
    鳞状细胞癌是影响口腔的常见恶性肿瘤,可能累及周围的颌面部区域。治疗通常包括切除肿瘤,然后对切除缺损进行修复。这份临床报告介绍了一名62岁的亚洲男性患者,他以前接受过手术切除,导致Aramany术后II级上颌骨缺损。患者的病史包括严重的三嘴,以张嘴受限为特征,以及上颌窦疣状鳞状细胞癌的诊断。本报告全面介绍了使用数字辅助牙科技术快速制造临时闭塞器的情况。
    Squamous cell carcinoma is a common malignant condition affecting the oral cavity and may involve the surrounding maxillofacial regions. Treatment commonly involves resection of the tumor, followed by prosthetic rehabilitation of the resection defect. This clinical report presents a 62-year-old Asian male patient who had previously undergone surgical resection, resulting in a post-surgical Aramany Class II maxillary defect. The patient\'s medical history included severe trismus, characterized by restricted mouth opening, as well as a diagnosis of maxillary sinus verrucous squamous cell carcinoma. This report provides a comprehensive account of the rapid fabrication of an interim obturator using digitally assisted dentistry techniques.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    In industrial production processes, rotational speed is a key parameter for equipment condition monitoring and fault diagnosis. To achieve rotational speed measurement of rotational equipment under a condition of high temperature and heavy dust, this article proposes a digital approach using an electrostatic sensor. The proposed method utilizes a strip of a predetermined material stuck on the rotational shaft which will accumulate a charge because of the relative motion with the air. Then an electrostatic sensor mounted near the strip is employed to obtain the fluctuating signal related to the rotation of the charged strip. Via a signal conversion circuit, a square wave, the frequency of which equals that of the rotation shaft can be obtained. Having the square wave, the M/T method and T method are adopted to work out the rotational speed. Experiments were conducted on a laboratory-scale test rig to compare the proposed method with the auto-correlation method. The largest relative errors of the auto-correlation method with the sampling rate of 2 ksps, 5 ksps are 3.2% and 1.3%, respectively. The relative errors using digital approaches are both within ±4‰. The linearity of the digital approach combined with the M/T method or T method is also superior to that of the auto-correlation method. The performance of the standard deviations and response speed was also compared and analyzed to show the priority of the digital approach.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

公众号