Technetium Tc 99m Sestamibi

Tech Tc 99m Sestamibi
  • 文章类型: Journal Article
    原发性甲状旁腺功能亢进(PHPT)是第三大最常见的内分泌疾病。甲状旁腺切除术,据报道,初次手术的治愈率超过95%。异常甲状旁腺的定位对于手术成功至关重要。这项研究的目的是分析接受微创甲状旁腺切除术(MIP)和术中甲状旁腺激素监测(IOPTH)的单腺疾病(SGD)和阳性一致定位成像患者的数据,以评估IOPTH在局限性SGD患者中是否仍然合理。
    回顾性数据库分析了2016-2021年期间在超声(US)和99mTc-sestamibi闪烁显像(MIBI)中使用IOPTH进行PHPT和阳性一致定位的所有微创手术。当美国和MIBI都为阴性时,患者接受胆碱或蛋氨酸PET-CT.患者也在不应用IOPTH的情况下进行了第二次分析。
    总共,198名患者被纳入研究。美国的敏感性,MIBI和PET-CT为96%,94%和100%,分别。阳性预测值为88%,89%和94%与美国,MIBI和PET-CT,分别。185例(93.4%)患者IOPTH为真阳性。在13例(6.6%)患者中,在定位和切除假定的甲状旁腺增大后,未观察到足够的IOPTH下降.没有IOPTH,治愈率从195例(98.5%)下降到182例(92%),持续性疾病发生率从2例(1.0%)上升到15例(7.5%).
    停止IOPTH会使合并局部腺瘤患者的持续率增加7.5倍。因此,即使对于这组患者,IOPTH似乎仍然是必要的。
    UNASSIGNED: Primary hyperparathyroidism (PHPT) is the third most common endocrine disease. With parathyroidectomy, a cure rate of over 95% at initial surgery is reported. Localization of the abnormal parathyroid gland is critical for the operation to be successful. The aim of this study is to analyze data of patients with single gland disease (SGD) and positive concordant localization imaging undergoing minimally invasive parathyroidectomy (MIP) and intraoperative parathyroid hormone monitoring (IOPTH) to evaluate if IOPTH is still justified in patients with localized SGD.
    UNASSIGNED: A retrospective database analysis of all minimally invasive operations with IOPTH for PHPT and positive concordant localization in ultrasound (US) and 99mTc-sestamibi scintigraphy (MIBI) between 2016-2021. When both US and MIBI were negative, patients underwent either choline or methionine PET-CT. The patients were also analyzed a second time without applying IOPTH.
    UNASSIGNED: In total, 198 patients were included in the study. The sensitivity of US, MIBI and PET-CT was 96%, 94% and 100%, respectively. Positive predictive value was 88%, 89% and 94% with US, MIBI and PET-CT, respectively. IOPTH was true positive in 185 (93.4%) patients. In 13 (6.6%) patients, no adequate IOPTH decline was observed after localizing and extirpating the assumed enlarged parathyroid gland. Without IOPTH, the cure rate decreased from 195 (98.5%) to 182 (92%) patients and the rate of persisting disease increased from 2 (1.0%) to 15 (7.5%) patients.
    UNASSIGNED: Discontinuing IOPTH significantly increases the persistence rate by a factor of 7.5 in patients with concordantly localized adenoma. Therefore, IOPTH appears to remain necessary even for this group of patients.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Editorial
    暂无摘要。
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    BACKGROUND: Gamma cameras with cadmium-zinc telluride (CZT) detectors allowed the quantification of myocardial flow reserve (MBF), which can increase the accuracy of myocardial perfusion scintigraphy (MPS) to detect the cause of chest discomfort.
    OBJECTIVE: To assess the clinical impact of MBF to detect the cause of chest discomfort.
    METHODS: 171 patients with chest discomfort who underwent coronary angiography or coronary CT angiography also underwent MPS and MBF in a time interval of <30 days. The acquisitions of dynamic imaging of rest and stress were initiated simultaneously with the 99mTc injection sestamibi (10 and 30mCi, respectively), both lasting eleven minutes, followed by immediately acquiring perfusion images for 5 minutes. The stress was performed with dipyridamole. A global or per coronary territory MBF <2.0 was classified as abnormal.
    RESULTS: The average age was 65.9±10 years (60% female). The anatomical evaluation showed that 115 (67.3%) patients had coronary obstruction significant, with 69 having abnormal MPs and 91 having abnormal MBF (60.0% vs 79.1%, p<0.01). Among patients without obstruction (56 - 32.7%), 7 had abnormal MPS, and 23 had reduced global MBF. Performing MBF identified the etiology of the chest discomfort in 114 patients while MPS identified it in 76 (66.7% vs 44.4%, p<0.001).
    CONCLUSIONS: MBF is a quantifiable physiological measure that increases the clinical impact of MPS in detecting the cause of chest discomfort through greater accuracy for detecting obstructive CAD, and it also makes it possible to identify the presence of the microvascular disease.
    OBJECTIVE: Gama-câmaras com detectores de telureto-cádmio-zinco (CZT) permitiram a quantificação da reserva de fluxo miocárdico (RFM), podendo aumentar a acurácia da cintilografia miocárdica de perfusão (CMP) para detectar a causa do desconforto torácico.
    OBJECTIVE: Avaliar o impacto clínico da RFM para detectar a causa do desconforto torácico.
    UNASSIGNED: 171 pacientes com desconforto torácico que foram submetidos a coronariografia ou angiotomografia de coronárias também realizaram CMP e RFM num intervalo de tempo <30 dias. As aquisições das imagens dinâmicas de repouso e estresse foram iniciadas simultaneamente à injeção de 99mTc sestamibi (10 e 30mCi, respectivamente), ambas com duração de onze minutos, seguidas imediatamente pela aquisição das imagens de perfusão durante 5 minutos. O estresse foi realizado com dipiridamol. Uma RFM global ou por território coronariano <2,0 foi classificada como anormal.
    RESULTS: A idade média foi de 65,9±10 anos (60% do sexo feminino). A avaliação anatômica mostrou que 115 (67,3%) pacientes apresentavam obstrução coronariana significativa, sendo que, 69 apresentavam CMP anormal e 91 apresentavam RFM anormal (60,0% vs. 79,1%, p<0,01). Dentre os pacientes sem obstrução (56 – 32,7%), 7 tinham CMP anormais e 23 tinham RFM global reduzida. A realização da RFM identificou a etiologia do desconforto torácico em 114 pacientes enquanto a CMP identificou em 76 (66,7% vs. 44,4%, p<0,001).
    UNASSIGNED: A RFM é uma medida fisiológica quantificável que aumenta o impacto clínico da CMP na detecção da causa do desconforto torácico através de uma maior acurácia para detecção de DAC obstrutiva e ainda possibilita identificar a presença de doença microvascular.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    F18-胆碱(FCH)正电子发射断层扫描(PET)/计算机断层扫描(CT)扫描是否可以代替Tc99m-sestaMIBI(MIBI)单光子发射(SPE)CT/CT作为原发性甲状旁腺功能亢进(PHPT)患者术前定位甲状旁腺腺瘤(PTA)的一线成像技术尚不清楚。
    比较一线FCHPET/CT与MIBISPECT/CT在需要甲状旁腺切除术的PHPT患者中的最佳护理,并比较一线成像方法导致手术后1个月成功的微创甲状旁腺切除术(MIP)和钙血症正常化的患者比例。
    进行了一项法国多中心随机开放诊断干预3期试验。患者于2019年11月至2022年5月招募,并在手术后6个月内参加。该研究包括患有PHPT和手术治疗适应症的成年人。既往有甲状旁腺手术或多发性内分泌肿瘤1型(MEN1)的患者不合格。
    患者按1:1的比例分配接受一线FCHPET/CT(FCH1)或MIBISPECT/CT(MIBI1)。如果一线成像阴性或不确定,他们在MIBI1后接受了二线FCHPET/CT(FCH2)或在FCH1后接受了MIBISPECT/CT(MIBI2).所有患者在最后一次成像后的12周内在全身麻醉下进行手术。手术后1个月和6个月进行临床和生物学(血清钙血症和甲状旁腺激素水平)评估。
    主要结果是真阳性一线成像引导的MIP结合术后1个月未校正的血清钙水平为2.55mmol/l或更低,对应于正态的局部上限。
    总的来说,57例患者接受FCH1(n=29)或MIBI1(n=28)。患者的平均(SD)年龄为62.8(12.5)岁,其中15名男性(26%)和42名女性(74%)患者。两组患者基线特征相似。FCH1组27例患者中的23例(85%)和MIBI1组25例患者中的14例(56%)在一线成像引导的MIP阳性后1个月观察到正常钙血症。FCH1和MIBI1的敏感性分别为82%(95%CI,62%-93%)和63%(95%CI,42%-80%)。对43例患者进行了6个月的生化检查随访,确认所有在手术后1个月患有正常血钙症的患者在6个月时仍然患有正常血钙症。未报告与影像学相关的不良事件和4例与手术相关的不良事件。
    这项随机临床试验发现,一线FCHPET/CT是MIBISPECT/CT的合适且安全的替代品。与MIBISPECT/CT相比,FCHPET/CT具有较高的敏感性,因此FCHPET/CT导致更多的PHPT患者纠正成像引导的MIP和正常钙血症。
    ClinicalTrials.gov标识符:NCT04040946。
    UNASSIGNED: Whether F18-choline (FCH) positron emission tomographic (PET)/computed tomographic (CT) scan can replace Tc99m-sestaMIBI (MIBI) single-photon emission (SPE)CT/CT as a first-line imaging technique for preoperative localization of parathyroid adenomas (PTA) in patients with primary hyperparathyroidism (PHPT) is unclear.
    UNASSIGNED: To compare first-line FCH PET/CT vs MIBI SPECT/CT for optimal care in patients with PHPT needing parathyroidectomy and to compare the proportions of patients in whom the first-line imaging method resulted in successful minimally invasive parathyroidectomy (MIP) and normalization of calcemia 1 month after surgery.
    UNASSIGNED: A French multicenter randomized open diagnostic intervention phase 3 trial was conducted. Patients were enrolled from November 2019 to May 2022 and participated up to 6 months after surgery. The study included adults with PHPT and an indication for surgical treatment. Patients with previous parathyroid surgery or multiple endocrine neoplasia type 1 (MEN1) were ineligible.
    UNASSIGNED: Patients were assigned in a 1:1 ratio to receive first-line FCH PET/CT (FCH1) or MIBI SPECT/CT (MIBI1). In the event of negative or inconclusive first-line imaging, they received second-line FCH PET/CT (FCH2) after MIBI1 or MIBI SPECT/CT (MIBI2) after FCH1. All patients underwent surgery under general anesthesia within 12 weeks following the last imaging. Clinical and biologic (serum calcemia and parathyroid hormone levels) assessments were performed 1 and 6 months after surgery.
    UNASSIGNED: The primary outcome was a true-positive first-line imaging-guided MIP combined with uncorrected serum calcium levels of 2.55 mmol/l or less 1 month after surgery, corresponding to the local upper limit of normality.
    UNASSIGNED: Overall, 57 patients received FCH1 (n = 29) or MIBI1 (n = 28). The mean (SD) age of patients was 62.8 (12.5) years with 15 male (26%) and 42 female (74%) patients. Baseline patient characteristics were similar between groups. Normocalcemia at 1 month after positive first-line imaging-guided MIP was observed in 23 of 27 patients (85%) in the FCH1 group and 14 of 25 patients (56%) in the MIBI1 group. Sensitivity was 82% (95% CI, 62%-93%) and 63% (95% CI, 42%-80%) for FCH1 and MIBI1, respectively. Follow-up at 6 months with biochemical measures was available in 43 patients, confirming that all patients with normocalcemia at 1 month after surgery still had it at 6 months. No adverse events related to imaging and 4 adverse events related to surgery were reported.
    UNASSIGNED: This randomized clinical trial found that first-line FCH PET/CT is a suitable and safe replacement for MIBI SPECT/CT. FCH PET/CT leads more patients with PHPT to correct imaging-guided MIP and normocalcemia than MIBI SPECT/CT thanks to its superior sensitivity.
    UNASSIGNED: ClinicalTrials.gov Identifier: NCT04040946.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    目的开发使用双探测器MBI的分子乳腺成像(MBI)引导活检系统,并对参与者进行初步测试。材料和方法立体导航MBI附件活检系统包括下部检测器,上部开窗压缩桨,和上部探测器。上部探测器缩回,允许头尾,斜,斜或内侧或外侧活检方法。压缩桨允许插入针引导件和针。通过在0°和15°处对上部探测器上的病变位置以及上部和下部探测器上的相对病变活动进行三角测量来计算病变深度。在一项前瞻性研究中(2022年7月至2023年6月),接受乳腺影像报告和数据系统2,3,4或5类乳腺病变的参与者接受了MBI引导活检.在注入740MBq99msestamibi后,头尾和中外侧斜MBI(每次2分钟采集)证实了病变的可视化。损伤上的感兴趣区域允许在系统软件中进行深度计算。上部检测器缩回允许放置活检装置。在缩回的上部检测器上获得样本图像,确认目标的采样。结果21名参与者(平均年龄,50.6岁±10.1[SD];21[100%]女性),17例接受MBI引导活检,病理一致。四名参与者在活检时未观察到病变。平均病变大小为17mm(范围,6-38毫米)。平均手术时间,包括术前成像,是55分钟±13(范围,38-90分钟)。病理结果包括浸润性导管癌(n=1),纤维腺瘤(n=4),假血管瘤间质增生(n=6),和纤维囊性改变(n=6)。结论MBI引导下采用可伸缩上探头的双头系统进行活检是可行的,良好的耐受性,高效。关键词:乳腺活检,分子乳腺成像,图像引导活检,分子乳腺成像引导活检,乳腺癌临床试验登记号。NCT06058650©RSNA,2024.
    Purpose To develop a molecular breast imaging (MBI)-guided biopsy system using dual-detector MBI and to perform initial testing in participants. Materials and Methods The Stereo Navigator MBI Accessory biopsy system comprises a lower detector, upper fenestrated compression paddle, and upper detector. The upper detector retracts, allowing craniocaudal, oblique, or medial or lateral biopsy approaches. The compression paddle allows insertion of a needle guide and needle. Lesion depth is calculated by triangulation of lesion location on the upper detector at 0° and 15° and relative lesion activity on upper and lower detectors. In a prospective study (July 2022-June 2023), participants with Breast Imaging Reporting and Data System category 2, 3, 4, or 5 breast lesions underwent MBI-guided biopsy. After injection of 740 MBq technetium 99m sestamibi, craniocaudal and mediolateral oblique MBI (2-minute acquisition per view) confirmed lesion visualization. A region of interest over the lesion permitted depth calculation in the system software. Upper detector retraction allowed biopsy device placement. Specimen images were obtained on the retracted upper detector, confirming sampling of the target. Results Of 21 participants enrolled (mean age, 50.6 years ± 10.1 [SD]; 21 [100%] women), 17 underwent MBI-guided biopsy with concordant pathology. No lesion was observed at the time of biopsy in four participants. Average lesion size was 17 mm (range, 6-38 mm). Average procedure time, including preprocedure imaging, was 55 minutes ± 13 (range, 38-90 minutes). Pathology results included invasive ductal carcinoma (n = 1), fibroadenoma (n = 4), pseudoangiomatous stromal hyperplasia (n = 6), and fibrocystic changes (n = 6). Conclusion MBI-guided biopsy using a dual-head system with retractable upper detector head was feasible, well tolerated, and efficient. Keywords: Breast Biopsy, Molecular Breast Imaging, Image-guided Biopsy, Molecular Breast Imaging-guided Biopsy, Breast Cancer Clinical trial registration no. NCT06058650 © RSNA, 2024.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    由于患者暴露于医学成像的电离辐射及其风险是持续存在的问题,本研究旨在评估心肌灌注单光子发射计算机断层扫描(MPS)后DNA损伤和修复标志物。研究了32例接受Tc-99msestamibiMPS的患者。在静息注射放射性示踪剂之前和注射后60-90分钟收集外周血。用外周血细胞进行彗星测定(单细胞凝胶电泳)以检测DNA链断裂。评估了三个描述符:彗星尾巴中DNA的百分比,尾部长度,和尾矩(DNA尾部百分比和尾部长度的乘积)。进行定量PCR(qPCR)以评估与响应DNA损伤和修复的信号通路相关的五个基因的表达(ATM,ATR,BRCA1,CDKN1A,和XPC)。采用Mann-Whitney检验进行统计分析;p<0.05被认为是显著的。Tc-99m的平均剂量为15.1mCi。注射放射性示踪剂后,将32名患者的暴露后样本与暴露前样本进行比较,尾部的DNA百分比没有统计学上的显著差异,发现了尾长或尾矩。qPCR显示BRCA1和XPC的表达增加,其他基因没有任何显著差异。在MPS的单次放射性示踪剂注射后,未检测到DNA链断裂的显着增加。只有两个修复基因被激活,这可能表明,在目前的病人样本中,电离辐射对DNA的影响不足以引发强烈的修复反应,表明没有明显的DNA损伤。
    As patient exposure to ionizing radiation from medical imaging and its risks are continuing issues, this study aimed to evaluate DNA damage and repair markers after myocardial perfusion single-photon emission computed tomography (MPS). Thirty-two patients undergoing Tc-99m sestamibi MPS were studied. Peripheral blood was collected before radiotracer injection at rest and 60-90 min after injection. The comet assay (single-cell gel electrophoresis) was performed with peripheral blood cells to detect DNA strand breaks. Three descriptors were evaluated: the percentage of DNA in the comet tail, tail length, and tail moment (the product of DNA tail percentage and tail length). Quantitative PCR (qPCR) was performed to evaluate the expression of five genes related to signaling pathways in response to DNA damage and repair (ATM, ATR, BRCA1, CDKN1A, and XPC). Mann-Whitney\'s test was employed for statistical analysis; p < 0.05 was considered significant. Mean Tc-99m sestamibi dose was 15.1 mCi. After radiotracer injection, comparing post-exposure to pre-exposure samples of each of the 32 patients, no statistically significant differences of the DNA percentage in the tail, tail length or tail moment were found. qPCR revealed increased expression of BRCA1 and XPC, without any significant difference regarding the other genes. No significant increase in DNA strand breaks was detected after a single radiotracer injection for MPS. There was activation of only two repair genes, which may indicate that, in the current patient sample, the effects of ionizing radiation on the DNA were not large enough to trigger intense repair responses, suggesting the absence of significant DNA damage.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Case Reports
    Technetium-99msestamibi单光子发射计算机断层扫描/计算机断层扫描(99mTc-sestamibiSPECT/CT)是甲状旁腺病变术前定位的主要依据。我们在这里报告了一名30岁妇女的病例,该妇女偶然发现了2厘米的宫颈肿块,由于其甲状腺后定位和个人肾结石病史,最初怀疑是甲状旁腺起源。正常血清钙和甲状旁腺激素(PTH)水平排除原发性甲状旁腺功能亢进,怀疑是无功能的甲状旁腺腺瘤,SPECT/CT显像显示肿块为99mTc-sestamibi-avid。进行细针穿刺(FNA);细胞学检查是非诊断性的,但甲状腺球蛋白的针头冲洗呈阴性,降钙素和PTH,反对肿块的甲状腺或甲状旁腺起源。核心针活检显示神经鞘瘤,表面上起源于喉返神经;手术切除后,最终发现它是由食管粘膜下层引起的。这个案例说明了内分泌学家,放射科医生,核医学,头部和颈部,和其他研究宫颈肿块患者的专家应该意识到,在颈部局灶性99mTc-sestamibi摄取的鉴别诊断中,需要考虑神经鞘瘤。
    Technetium-99m sestamibi single-photon emission computed tomography/computed tomography (99mTc-sestamibi SPECT/CT) is a mainstay of the pre-operative localization of parathyroid lesions. We report here the case of a 30 year-old woman with a fortuitously discovered 2 cm cervical mass for which a parathyroid origin was originally suspected due to its retro-thyroidal localization and a personal history of nephrolithiasis. Normal serum calcium and parathyroid hormone (PTH) levels excluded primary hyperparathyroidism, raising suspicion of a non-functional parathyroid adenoma, and SPECT/CT imaging showed that the mass was 99mTc-sestamibi-avid. Fine-needle aspiration (FNA) was performed; cytology was non-diagnostic but the needle washout was negative for thyroglobulin, calcitonin and PTH, arguing against a thyroidal or parathyroidal origin of the mass. Core needle biopsy revealed a schwannoma, ostensibly originating from the recurrent laryngeal nerve; upon surgical resection, it was finally found to arise from the esophageal submucosa. This case illustrates the fact that endocrinologists, radiologists, nuclear medicine, head and neck, and other specialists investigating patients with cervical masses should be aware that schwannomas need to be considered in the differential diagnosis of focal 99mTc-sestamibi uptake in the neck region.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    99mTc-MIBI闪烁显像是一种核医学成像方式,通常用于甲状旁腺功能亢进患者的甲状旁腺腺瘤的术前定位。此外,99mTc-MIBI由于其独特的细胞内积累机制,也可用于各种肿瘤的成像。这里,我们介绍了一个单一的99mTc-MIBISPECT/CT同时可视化两种不同的恶性肿瘤,如甲状腺乳头状癌和小细胞肺癌,伴有甲状旁腺功能亢进患者的甲状旁腺腺瘤。通过将其与三种肿瘤中的18F-FDGPET/CT进行比较,还探讨了99mTc-MIBISPECT/CT的临床实用性。
    UNASSIGNED: 99m Tc-MIBI scintigraphy is a nuclear medicine imaging modality commonly used for the preoperative localization of parathyroid adenomas in patients with hyperparathyroidism. In addition, 99m Tc-MIBI can also be used for imaging various tumors due to its unique mechanism of intracellular accumulation. Here, we introduced a case of a single 99m Tc-MIBI SPECT/CT simultaneously visualized two different malignant tumors, such as papillary thyroid cancer and small cell lung cancer, along with a parathyroid adenoma in a patient with hyperparathyroidism. The clinical usefulness of 99m Tc-MIBI SPECT/CT was also explored by comparing it with 18 F-FDG PET/CT among the three tumors.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    背景:探测流成像(DFI)是一种显示低速血流的新成像技术,在常规彩色多普勒超声(CDU)上很难观察。在这项研究中,我们比较了DFI与CDU和甲氧基-异丁基-异腈(MIBI)闪烁显像在原发性甲状旁腺功能亢进(PHPT)患者中检测甲状旁腺腺瘤(PA)的有效性.
    方法:从2021年3月至2023年3月,87名PHPT患者接受了手术,66个有一个PA。我们进行了术前常规超声与CDU,MIBI闪烁显像,和DFI42例患者(男5例,女37例;平均年龄:61.6±15.4岁)。
    结果:MIBI闪烁显像在85.7%(36/42)的患者中检测到PA,CDU和DFI在所有患者中均检测到PA。CDU和DFI检测PA的血管分布率分别为71.4%(30/42)和85.7%(36/42),分别。在6例MIBI闪烁显像检查血管阴性的患者中,通过DFI检测到血管。此外,DFI在12例CDU上检测不到血供的患者中有6例检测到血供。费希尔的精确测试显示血流量高或低,由DFI确定,与CDU检测PA中的喂养血管显着相关(P<0.001)。
    结论:DFI可用于术前检测PA血流。
    BACKGROUND: Detective flow imaging (DFI) is a new imaging technology that displays low-velocity blood flow, which is difficult to visualize on conventional color Doppler ultrasonography (CDU). In this study, we compared the usefulness of DFI with that of CDU and methoxy-isobutyl-isonitrile (MIBI) scintigraphy for detecting parathyroid adenoma (PA) in patients with primary hyperparathyroidism (PHPT).
    METHODS: From March 2021 to March 2023, 87 PHPT patients underwent surgery, and 66 had a single PA. We performed preoperative conventional ultrasonography with CDU, MIBI scintigraphy, and DFI for 42 patients (5 males and 37 females; mean age: 61.6 ± 15.4 years).
    RESULTS: MIBI scintigraphy detected PA in 85.7% (36/42) patients, and both CDU and DFI detected PA in all patients. The rates of vascularity in PA detected by CDU and DFI were 71.4% (30/42) and 85.7% (36/42), respectively. Vascularity was detected by DFI in 6 patients who were negative for vascularity on MIBI scintigraphy. Furthermore, DFI detected blood supply in 6 of the 12 patients with undetectable blood supply on CDU. Fisher\'s exact test revealed that high or low blood flow, as determined by DFI, was significantly associated with detection of feeding vessels in PA by CDU (P < 0.001).
    CONCLUSIONS: DFI was useful for preoperative detection of PA blood flow.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    背景:原发性甲状旁腺功能亢进,虽然在内分泌失调中相对普遍,影响了1%的总人口,经常提出诊断挑战。鉴于其可能导致严重的并发症,包括肾结石和骨折,及时诊断,有效的管理至关重要。
    方法:一名患有高钙血症的38岁女性患者被转诊到核医学科进行Tc-99mMIBI扫描。
    方法:Tc-99mMIBI扫描显示左侧甲状腺区域局部摄取增加,最初提示甲状旁腺腺瘤.使用SPECT/CT进行的进一步检查显示,左侧甲状腺内有结节性病变,显示高Tc-99mMIBI摄取。
    方法:甲状腺左侧肿块切除证实病灶为甲状腺滤泡状癌。在甲状腺全切除术后进行的第二次Tc-99mMIBI扫描中,最终在右下部区域发现了甲状旁腺腺瘤,能够进行后续的适当治疗,右下甲状旁腺切除术.
    结果:甲状旁腺切除术后13天,血清总钙和甲状旁腺激素水平恢复正常。此外,即使在14个月后,使用DEXA评估的骨矿物质密度仍保持在其年龄的预期范围内.
    结论:解释Tc-99mMIBI扫描时,必须记住,富含线粒体的各种肿瘤,比如甲状腺癌,可以显示对Tc-99mMIBI的高摄取。
    BACKGROUND: Primary hyperparathyroidism, though relatively prevalent among endocrine disorders, affecting 1% of the general population, often presents diagnostic challenges. Given its potential to precipitate severe complications including nephrolithiasis and fractures, timely diagnosis, and effective management are crucial.
    METHODS: A 38-year-old woman with hypercalcemia was referred to the Department of Nuclear Medicine for a Tc-99m MIBI scan.
    METHODS: Tc-99m MIBI scan showed focal increased uptake in the left thyroid gland area, initially suggesting a parathyroid adenoma. Further examination using SPECT/CT revealed a nodular lesion within the left thyroid gland showing high Tc-99m MIBI uptake.
    METHODS: Left thyroid lumpectomy confirmed the lesion as follicular thyroid carcinoma. On the second Tc-99m MIBI scan conducted after total thyroidectomy, a parathyroid adenoma was eventually detected in the right lower area, enabling the subsequent appropriate treatment, a right lower parathyroidectomy.
    RESULTS: Thirteen days after the parathyroidectomy, serum levels of total calcium and parathyroid hormone returned to normal. Furthermore, bone mineral density evaluated using DEXA remained within the expected range for her age even after 14 months.
    CONCLUSIONS: When interpreting the Tc-99m MIBI scan, it is essential to keep in mind that various tumors rich in mitochondria, such as thyroid carcinoma, could show a high uptake of Tc-99m MIBI.