MiSeq FGx™ system

MiSeq FGx ™ 系统
  • 文章类型: Journal Article
    Massively parallel sequencing (MPS), or next generation sequencing (NGS), is a promising methodology for the detection of short tandem repeats (STRs) and single nucleotide polymorphisms (SNPs) in forensic genetics. Here, the prototype SifaMPS Panel is designed to simultaneously target 87 STRs and 294 SNPs with forensic interest in a single multiplex in conjunction with the TruSeq™ Custom Amplicon workflow and MiSeq FGx™ System. Two in-house python scripts are adopted for the fastq-to-genotype interpretation of MPS data concerning STR and SNP, respectively. In the present study, by sequencing 50 Chinese Hans and many other DNA samples involved in validation studies, system parameters including the depth of coverage (DoC), heterozygote balance (Hb) and sequence coverage ratios (SCRs), as well as different forensic parameters of STRs and SNPs in a population study, were calculated to evaluate the overall performance of this new panel and its practicality in forensic application. In general, except for two STRs (DYS505 and DYS449) and one SNP (rs4288409) that performed poorly, the other 85 STRs and 293 SNPs in our panel had good performance that could strengthen efficiency for human identification and paternity testing. In addition, discordant STR genotype results between those generated from capillary electrophoresis (CE) and from the MPS platform were clearly illustrated, and these results could be a useful reference for applying these particular non-CODIS STRs in forensic practice.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Human DNA profiling using PCR at polymorphic short tandem repeat (STR) loci followed by capillary electrophoresis (CE) size separation and length-based allele typing has been the standard in the forensic community for over 20 years. Over the last decade, Next-Generation Sequencing (NGS) matured rapidly, bringing modern advantages to forensic DNA analysis. The MiSeq FGx™ Forensic Genomics System, comprised of the ForenSeq™ DNA Signature Prep Kit, MiSeq FGx™ Reagent Kit, MiSeq FGx™ instrument and ForenSeq™ Universal Analysis Software, uses PCR to simultaneously amplify up to 231 forensic loci in a single multiplex reaction. Targeted loci include Amelogenin, 27 common, forensic autosomal STRs, 24 Y-STRs, 7 X-STRs and three classes of single nucleotide polymorphisms (SNPs). The ForenSeq™ kit includes two primer sets: Amelogenin, 58 STRs and 94 identity informative SNPs (iiSNPs) are amplified using DNA Primer Set A (DPMA; 153 loci); if a laboratory chooses to generate investigative leads using DNA Primer Set B, amplification is targeted to the 153 loci in DPMA plus 22 phenotypic informative (piSNPs) and 56 biogeographical ancestry SNPs (aiSNPs). High-resolution genotypes, including detection of intra-STR sequence variants, are semi-automatically generated with the ForenSeq™ software. This system was subjected to developmental validation studies according to the 2012 Revised SWGDAM Validation Guidelines. A two-step PCR first amplifies the target forensic STR and SNP loci (PCR1); unique, sample-specific indexed adapters or \"barcodes\" are attached in PCR2. Approximately 1736 ForenSeq™ reactions were analyzed. Studies include DNA substrate testing (cotton swabs, FTA cards, filter paper), species studies from a range of nonhuman organisms, DNA input sensitivity studies from 1ng down to 7.8pg, two-person human DNA mixture testing with three genotype combinations, stability analysis of partially degraded DNA, and effects of five commonly encountered PCR inhibitors. Calculations from ForenSeq™ STR and SNP repeatability and reproducibility studies (1ng template) indicate 100.0% accuracy of the MiSeq FGx™ System in allele calling relative to CE for STRs (1260 samples), and >99.1% accuracy relative to bead array typing for SNPs (1260 samples for iiSNPs, 310 samples for aiSNPs and piSNPs), with >99.0% and >97.8% precision, respectively. Call rates of >99.0% were observed for all STRs and SNPs amplified with both ForenSeq™ primer mixes. Limitations of the MiSeq FGx™ System are discussed. Results described here demonstrate that the MiSeq FGx™ System meets forensic DNA quality assurance guidelines with robust, reliable, and reproducible performance on samples of various quantities and qualities.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号