High-viscosity cement

  • 文章类型: Journal Article
    症状性骨质疏松性压缩性骨折通常通过椎体成形术和椎体后凸成形术解决。然而,水泥渗漏会带来严重的神经损伤风险。我们介绍了“抽吸式经皮椎体后凸成形术”,也被称为“减压椎体后凸成形术”,作为减轻骨水泥渗漏的方法,并与高粘度骨水泥椎体成形术进行了比较分析。我们进行了一项回顾性研究,包括136例单级别骨质疏松性压缩骨折患者。其中,70例患者接受高粘度骨水泥椎体成形术,66例患者接受了低粘度骨水泥减压经皮椎体后凸成形术。比较参数包括水泥渗漏率,后倾角改变,以及相邻节段骨折的发生。整体骨水泥渗漏率有利于减压后凸成形术组(9.1%vs.18.6%),虽然没有达到统计学意义(p=0.111).尽管如此,在减压后凸成形术队列中,椎间盘内漏的风险显着降低(p=0.011),这在缺乏X线术前裂痕的病例中尤为明显。后倾角变化和相邻节段塌陷的风险表现出相似的结果(分别为p=0.739和0.522)。我们得出的结论是,减压后凸成形术显示出减少椎间盘内水泥渗漏的功效,通过防止椎间盘内漏,特别有利于在X线片上没有术前裂隙征的患者。
    Symptomatic osteoporotic compression fractures are commonly addressed through vertebroplasty and kyphoplasty. However, cement leakage poses a significant risk of neurological damage. We introduced \"aspiration percutaneous kyphoplasty\", also known as \"decompressed kyphoplasty\", as a method to mitigate cement leakage and conducted a comparative analysis with high viscosity cement vertebroplasty. We conducted a retrospective study that included 136 patients with single-level osteoporotic compression fractures. Among them, 70 patients underwent high viscosity cement vertebroplasty, while 66 patients received decompressed percutaneous kyphoplasty with low-viscosity cement. Comparison parameters included cement leakage rates, kyphotic angle alterations, and the occurrence of adjacent segment fractures. The overall cement leakage rate favored the decompressed kyphoplasty group (9.1% vs. 18.6%), although statistical significance was not achieved (p = 0.111). Nonetheless, the risk of intradiscal leakage significantly reduced in the decompressed kyphoplasty cohort (p = 0.011), which was particularly evident in cases lacking the preoperative cleft sign on X-rays. Kyphotic angle changes and the risk of adjacent segment collapse exhibited similar outcomes (p = 0.739 and 0.522, respectively). We concluded that decompressed kyphoplasty demonstrates efficacy in reducing intradiscal cement leakage, particularly benefiting patients without the preoperative cleft sign on X-rays by preventing intradiscal leakage.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    Aseptic loosening (AL) is the most common reason for revision total knee arthroplasty (TKA). An association between high-viscosity cement (HVC) and AL has been suggested by small, uncontrolled, case series. This study sought to determine whether HVC use during primary TKA is independently associated with AL requiring revision.
    We retrospectively analyzed a prospectively collected institutional knee registry to identify all primary TKAs from January 2007 to December 2016. Patients with less than 2 years of follow-up were excluded. Cement type was divided into 2 groups: HVC and low-viscosity cement. Potential confounders including age, body mass index, preoperative diagnosis, antibiotics in the cement, and implant type were recorded. Multivariable logistic regression analysis was used to determine whether HVC is independently associated with revision for AL.
    In total, 10,014 patients were included. Revision for AL was significantly higher in the HVC cohort (91/4790; 1.9%) vs the low-viscosity cement cohort (48/5224; 0.92%) (P < .001). Logistic regression demonstrated HVC to be independently associated with higher odds of revision for AL (odds ratio 2.26, 95% confidence interval 1.58-3.22, P < .001). Younger age was also associated with higher odds of revision for AL (odds ratio 0.96, 95% confidence interval 0.94-0.98, P < .001). Body mass index, gender, laterality, preoperative diagnosis, and antibiotics in the cement were not associated with revision for AL. Implant manufacturer, implant design, and cement brand all impacted the odds of undergoing revision for AL.
    Although HVC is an attractive option for use in primary TKA, this appropriately controlled study demonstrates higher odds of revision for AL when using HVC with multiple different implant types.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Comparative Study
    OBJECTIVE: To evaluate and compare clinical outcomes and cement leakage of high-viscosity bone cement versus low-viscosity bone cement vertebroplasty in treating osteoporotic vertebral compression fractures with intravertebral cleft.
    METHODS: The study included 72 patients with osteoporotic vertebral compression fractures with intravertebral cleft, who were divided into high-viscosity cement (HVC) (38 cases) and low-viscosity cement (LVC) (34 cases) groups according to the viscosity of bone cement used. Cement leakage, visual analog scale score, Oswestry Disability Index, and kyphotic angle (KA) were evaluated.
    RESULTS: All patients were followed for at least 12 months. Overall cement leakage rate was 18.4% in the HVC group, lower than the rate of 61.8% obtained in the LVC group. A statistically significant difference was found in the overall cement leakage rate between the groups (P < 0.05). Visual analog scale and Oswestry Disability Index scores were significantly improved after percutaneous vertebroplasty without significant differences between the HVC and LVC groups (P > 0.05). The KA of patients from both groups was also significantly corrected immediately after surgery. Although the KA gradually increased in both groups during the follow-up period, there was no statistically significant difference between the HVC and LVC groups in KA during follow-up (P > 0.05).
    CONCLUSIONS: Percutaneous vertebroplasty using HVC to treat osteoporotic vertebral compression fractures with intravertebral cleft significantly reduces cement leakage and improves the safety of the operation. In terms of clinical efficacy and prevention of augmented vertebral recollapse, HVC may not have obvious advantages.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Comparative Study
    OBJECTIVE: This study mainly aimed to evaluate complications of cement leakage for osteoporotic thoracolumbar vertebral compression fractures by PVP using HVC, and access the clinical efficacy.
    METHODS: Between May 2013 and June 2015, 66 patients with osteoporotic thoracolumbar vertebral compression fractures, who underwent PVP (36 HVC and 30 LVC) in our hospital, were enrolled. Cement leakage, Visual Analog Scale (VAS), Oswestry Disability Index (ODI), refracture of the cemented vertebrae, and adjacent vertebral fractures were evaluated. The follow-up time was 1 year.
    RESULTS: The overall cement leakage rate was 30.55% in the HVC group, lower than 77.77% obtained in the LVC group (P = 0.00). The incidence rates of cement leakage into paravertebral area (P = 0.02) and vein (P = 0.04) in the HVC group were significantly lower than those of the LVC group; however, no differences were found for disc space (P = 0.72) and intraspinal space (P = 0.58). There were no differences in VAS, ODI, refracture of cemented vertebrae, and adjacent vertebral fracture between the two groups (P > 0.05).
    CONCLUSIONS: PVP using HVC not only can reduce cement leakage, especially in the paravertebral area and peripheral vein, but also has satisfactory clinical effect.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Recent literature has shown debonding of the tibial implant-cement interface as a potential cause for implant loosening. The purpose of this case series is to report this phenomenon in a historically well-performing implant when used with high-viscosity cement (HVC).
    Thirteen primary cemented Biomet Vanguard total knee arthroplasties were referred to 1 of 2 institutions with complaints of persistent pain after their index procedure. A radiographic and infectious work-up was completed for each patient. All 13 patients underwent a revision of the index surgery with intraoperative diagnosis of tibial component debonding at the implant-cement interface. HVC (Cobalt, DJO Surgical, Vista, CA and Depuy HVC; Depuy Inc, Warsaw, IN) was used in all index cases.
    The average time to revision surgery for the 13 patients was 2.7 ± 1.9 years from the index surgery. Laboratory infectious markers were within normal in most cases, and all intra-articular aspirations showed no bacterial, fungal, or anaerobic growth. Eleven of 13 patients showed no radiographic evidence of loosening; however, all cases demonstrated tibial component debonding intraoperatively.
    Given our institution\'s experience and previously reported data demonstrating excellent survivorship with this total knee arthroplasty prosthesis, we propose that the early failures seen in this case series may be associated with the use of HVC cement. In the setting of a negative infectious work-up and no radiographic evidence to suggest loosening, the surgeon should consider debonding of the tibial component as a potential cause for persistent pain if HVC cement was used with this prosthetic design.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    BACKGROUND: Early failure in cemented total knee replacement (TKR) due to aseptic loosening is uncommon. A small number of early failures requiring revision were observed at one hospital due to observed cement-implant fixation failure. The purpose of this case series is to report and identify possible causes for these early failures.
    METHODS: Between May 2005 and December 2010, 3048 primary TKRs were performed over a five-year period of time by six surgeons. Two total knee systems were used during this period of time. Nine early failures were observed in eight patients. High viscosity cement (HVC) was used in all these cases.
    RESULTS: Aseptic loosening of the tibial component was observed in all nine early total knee failures. The high viscosity bone cement was noted to be non-adherent to the tibial trays at the time of revision surgery. HVC was used in all these cases.
    CONCLUSIONS: Properties of HVC may contribute to make it more susceptible to early failure in a small number of TKRs. HVC in total hip replacement (THR) has been associated with cement micro-fractures, cement debris generation and early implant failure. The mechanical properties of HVC may similarly contribute to early failure at the cement-implant interface in a small percentage TKRs.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号