Edema corneal

  • 文章类型: Case Reports
    角膜水肿和内皮细胞计数减少是与隐形眼镜配戴者经历的慢性低度缺氧相关的并发症。主要是由于长时间和过夜的磨损。此病例显示了一个患者的例子,该患者的双眼视力模糊,并且接受了包括照片在内的完整眼科检查,角膜地形图和内皮细胞计数。随后,角膜代谢,我们回顾了接触镜的病因和并发症。
    Corneal edema and decreased endothelial cell count are complications related to chronic low-grade hypoxia experienced by contact lens wearers, primarily due to prolonged and overnight wear. This case shows the example of a patient who has blurred vision problems in both eyes and who underwent a complete ophthalmologic examination that included photographs, corneal topography and endothelial cell count. Subsequently, the corneal metabolism, the etiopathogenesis and the complications derived from the use of contact lenses are reviewed.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    OBJECTIVE: To describe intracameral toxic effects of cefuroxime at a higher dose than recommended in cataract surgery.
    METHODS: Retrospective study of 8 eyes of 8 patients who inadvertently received 12.5 mg/0.1 ml of intracameral cefuroxime due to a dilution error, at the end of the cataract surgery. All patients underwent a strict ophthalmology follow-up for 6 months.
    RESULTS: All patients presented with a marked anterior segment inflammation with corneal oedema that resolved completely in all cases (between 5 days and 3 months). At 6 months of follow-up a statistically significant difference was found in the corneal endothelial cell density when compared with the fellow eye (P = .038), being <1000 cells/mm2 in 3 cases. Three patients (37.5%) showed early macular oedema, with subfoveal ellipsoid layer disruption in one case as a permanent sequel. One patient developed an optic neuropathy with associated afferent pupillary defect.
    CONCLUSIONS: Although 1 mg/0.1 ml of intracameral cefuroxime has been shown to reduce the incidence of endophthalmitis, its overdose can have potentially toxic eye effects in both anterior and posterior segments.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:描述头孢呋辛在白内障手术中的剂量高于推荐剂量的前房内毒性作用。
    方法:对8例患者的8只眼进行回顾性研究,这些患者由于稀释误差而无意中接受了12.5mg/0.1ml头孢呋辛,在白内障手术结束时。所有患者均接受了为期6个月的严格眼科随访。
    结果:所有患者均出现明显的眼前节炎症伴角膜水肿,在所有情况下(5天至3个月之间)完全消退。在随访6个月时,与同眼相比,发现角膜内皮细胞密度有统计学意义的差异(P=0.038),在3种情况下<1000个细胞/mm2。3例患者(37.5%)出现早期黄斑水肿,在一种情况下,中央凹下的椭圆体层破裂是永久的续集。一名患者出现视神经病变并伴有传入瞳孔缺损。
    结论:虽然前房内注射1mg/0.1ml头孢呋辛可降低眼内炎的发生率,它的过量可能对前段和后段都有潜在的毒性作用。
    OBJECTIVE: To describe intracameral toxic effects of cefuroxime at a higher dose than recommended in cataract surgery.
    METHODS: Retrospective study of 8 eyes of 8 patients who inadvertently received 12.5mg/0.1ml of intracameral cefuroxime due to a dilution error, at the end of the cataract surgery. All patients underwent a strict ophthalmology follow-up for 6 months.
    RESULTS: All patients presented with a marked anterior segment inflammation with corneal oedema that resolved completely in all cases (between 5 days and 3 months). At 6 months of follow-up a statistically significant difference was found in the corneal endothelial cell density when compared with the fellow eye (P=.038), being<1000 cells/mm2 in 3 cases. Three patients (37.5%) showed early macular oedema, with subfoveal ellipsoid layer disruption in one case as a permanent sequel. One patient developed an optic neuropathy with associated afferent pupillary defect.
    CONCLUSIONS: Although 1mg/0.1ml of intracameral cefuroxime has been shown to reduce the incidence of endophthalmitis, its overdose can have potentially toxic eye effects in both anterior and posterior segments.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    METHODS: A 70 year-old male patient with a history of radial keratotomy suffering from Fuchs\' dystrophy and a cataract. The patient received a two-step surgery: lens phacoemulsification and intraocular lens implant, followed by descemet stripping automated endothelial keratoplasty in both eyes, four months later. There were no complications apart from a recurrent cystoid macular oedema in both eyes. The best corrected visual acuity was 20/40 both eyes, and the patient was satisfied.
    CONCLUSIONS: Descemet stripping automated endothelial keratoplasty may be considered as an alternative to penetrating keratoplasty in the case of endothelial dysfunction and radial keratotomy in patients with no corneal ectasia or significant stromal opacity.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    METHODS: A middle-aged adult male was referred to our institution due to unilateral corneal edema for a possible corneal transplant. At first, the patient denied a history of trauma. A small foreign body, which had been overlooked by the primary ophthalmologist, was detected by gonioscopy, embedded in the anterior chamber angle. It was successfully surgically removed and visual results were good.
    CONCLUSIONS: In any patient with unilateral unexplained corneal edema, it is necessary to rule out the presence of a foreign body in the anterior chamber.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    OBJECTIVE: To compare central corneal swelling after eight hours of sleep in eyes wearing four different silicone hydrogel lenses with three different powers.
    METHODS: Twenty-nine neophyte subjects wore lotrafilcon A (Dk, 140), balafilcon A (Dk, 91), galyfilcon A (Dk, 60) and senofilcon A (Dk, 103) lenses in powers -3.00, -10.00 and +6.00 D on separate nights, in random order, and on one eye only. The contra-lateral eye (no lens) served as the control. Central corneal thickness was measured using a digital optical pachometer before lens insertion and immediately after lens removal on waking.
    RESULTS: For the +6.00 D and -10.00 D, lotrafilcon A induced the least swelling and galyfilcon A the most. The +6.00 D power, averaged across lens materials, induced significantly greater central swelling than the -10.00 and -3.00 D (Re-ANOVA, p<0.001), (7.7±2.9% vs. 6.8±2.8% and 6.5±2.5% respectively) but there was no difference between -10.00 and -3.00 D. Averaged for power, lotrafilcon A induced the least (6.2±2.8%) and galyfilcon A the most (7.6±3.0%) swelling at the center (Re-ANOVA, p<0.001). Central corneal swelling with +6.00 D was significantly greater than -10.00 D lens power despite similar levels of average lens transmissibility of these two lens powers.
    CONCLUSIONS: The differences in corneal swelling of the lens wearing eyes are consistent with the differences in oxygen transmission of the silicone hydrogel lenses. In silicone hydrogel lenses central corneal swelling is mainly driven by central lens oxygen transmissibility.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号