    使用90Y选择性内部放射疗法(SIRT)治疗肝脏恶性肿瘤可能会损害功能性肝实质。评估功能性实质变化并开发吸收剂量(AD)毒性模型可以帮助接受SIRT的患者的临床管理。我们旨在确定在SIRT之前和之后,90YPETAD体素图与动态gadoxetic酸增强MRI得出的非肿瘤肝脏(NTL)功能的空间变化之间是否存在相关性。方法:对11例接受90YSIRT治疗的患者,在治疗前后进行动态gadoxetic酸增强MRI扫描。从MRI数据生成直接量化空间肝实质功能的Gadoxetic酸摄取率(k1)图。基于体素的AD地图,来自90YPET/CT扫描,根据AD分类。SIRT前和后k1图被共同注册到AD图。计算每个箱中k1损失的绝对和百分比,作为肝功能损失的量度,对每位患者的k1丢失和AD之间的Spearman相关系数进行评估。患者的平均k1损失符合基于AD的3参数逻辑函数。根据病变类型将患者进一步分为亚组,基线白蛋白-胆红素评分和丙氨酸转氨酶水平,剂量-体积效应,和SIRT治疗的数量。结果:在大多数患者(8/11)中,k1绝对丢失和百分比丢失与AD之间存在显着正相关(ρ=0.53-0.99,P<0.001)。9例患者的平均k1损失也显示出与AD的显着强相关性(ρ≥0.92,P<0.001)。AD患者k1丢失的平均百分比为28%,逻辑函数模型表明,在约100Gy时,k1损失约25%。患者亚组之间的分析表明,在肝细胞癌患者中k1丢失更大,更高的丙氨酸转氨酶水平,接受70Gy或更高AD的NTL的分数更大,和连续SIRT治疗。结论:多模态成像的新应用证明了90YSIRTAD与空间功能性肝实质降解之间的相关性,表明较高的AD与局部肝细胞功能的较大丧失有关。有了开发的响应模型,PET衍生的AD图可以潜在地用于识别肝脏中的局部损伤并增强治疗策略。
    Functional liver parenchyma can be damaged from treatment of liver malignancies with 90Y selective internal radiation therapy (SIRT). Evaluating functional parenchymal changes and developing an absorbed dose (AD)-toxicity model can assist the clinical management of patients receiving SIRT. We aimed to determine whether there is a correlation between 90Y PET AD voxel maps and spatial changes in the nontumoral liver (NTL) function derived from dynamic gadoxetic acid-enhanced MRI before and after SIRT. Methods: Dynamic gadoxetic acid-enhanced MRI scans were acquired before and after treatment for 11 patients undergoing 90Y SIRT. Gadoxetic acid uptake rate (k1) maps that directly quantify spatial liver parenchymal function were generated from MRI data. Voxel-based AD maps, derived from the 90Y PET/CT scans, were binned according to AD. Pre- and post-SIRT k1 maps were coregistered to the AD map. Absolute and percentage k1 loss in each bin was calculated as a measure of loss of liver function, and Spearman correlation coefficients between k1 loss and AD were evaluated for each patient. Average k1 loss over the patients was fit to a 3-parameter logistic function based on AD. Patients were further stratified into subgroups based on lesion type, baseline albumin-bilirubin scores and alanine transaminase levels, dose-volume effect, and number of SIRT treatments. Results: Significant positive correlations (ρ = 0.53-0.99, P < 0.001) between both absolute and percentage k1 loss and AD were observed in most patients (8/11). The average k1 loss over 9 patients also exhibited a significant strong correlation with AD (ρ ≥ 0.92, P < 0.001). The average percentage k1 loss of patients across AD bins was 28%, with a logistic function model demonstrating about a 25% k1 loss at about 100 Gy. Analysis between patient subgroups demonstrated that k1 loss was greater among patients with hepatocellular carcinoma, higher alanine transaminase levels, larger fractional volumes of NTL receiving an AD of 70 Gy or more, and sequential SIRT treatments. Conclusion: Novel application of multimodality imaging demonstrated a correlation between 90Y SIRT AD and spatial functional liver parenchymal degradation, indicating that a higher AD is associated with a larger loss of local hepatocyte function. With the developed response models, PET-derived AD maps can potentially be used prospectively to identify localized damage in liver and to enhance treatment strategies.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    背景:我们研究的目的是比较从PET/MRI和PET/CT治疗后成像获得的90Y剂量学在原发性或转移性肝肿瘤患者中的应用。首先,在PET/CT和PET/MRI系统上都获得了一个充满水的Jaszczak体模,其中包含90Y氯化物的可填充球体,以检查模式的交叉校准。使用90Y微球进行选择性内部放射治疗(SIRT)后,32例患者在PET/CT系统上成像,立即进行PET/MRI研究。将重建的图像转移到公共平台并用于计算90Y剂量测定。使用Passing-Bablok回归散点图和Bland和Altman方法分析了剂量测定值之间的差异。
    结果:体模研究表明,两种模式的校准误差均小于1%。根据PET/CT和PET/MRI计算的32名受试者的平均肝脏剂量分别为51.6±24.7Gy和46.5±22.7Gy,分别,平均差为5.1±5.0Gy。重复性系数为9.0(平均值的18.5%)。Spearman等级相关系数很高,ρ=0.97。尽管肝脏的最大剂量可能会有很大差异(高达40%),每种模式的平均肝脏剂量相对接近,相差18.5%或更小。
    结论:使用PET/CT与PET/MRI的90Y剂量学计算差异的两个主要原因可以归因于感兴趣区域(ROI)的差异和归因于衰减校正的差异。由于MRI的优越的软组织对比度,肝脏轮廓通常比CT图像更好。然而,PET/CT可以更好地量化PET图像,由于更好的衰减校正。尽管存在这些差异,我们的结果表明,治疗后90Y研究中PET/MRI和PET/CT的剂量学值相似.
    BACKGROUND: The aim of our study was to compare 90Y dosimetry obtained from PET/MRI versus PET/CT post-therapy imaging among patients with primary or metastatic hepatic tumors. First, a water-filled Jaszczak phantom containing fillable sphere with 90Y-chloride was acquired on both the PET/CT and PET/MRI systems, in order to check the cross-calibration of the modalities. Following selective internal radiation therapy (SIRT) with 90Y microspheres, 32 patients were imaged on a PET/CT system, immediately followed by a PET/MRI study. Reconstructed images were transferred to a common platform and used to calculate 90Y dosimetry. A Passing-Bablok regression scatter diagram and the Bland and Altman method were used to analyze the difference between the dosimetry values.
    RESULTS: The phantom study showed that both modalities were calibrated with less than 1% error. The mean liver doses for the 32 subjects calculated from PET/CT and PET/MRI were 51.6 ± 24.7 Gy and 46.5 ± 22.7 Gy, respectively, with a mean difference of 5.1 ± 5.0 Gy. The repeatability coefficient was 9.0 (18.5% of the mean). The Spearman rank correlation coefficient was very high, ρ = 0.97. Although the maximum dose to the liver can be significantly different (up to 40%), mean liver doses from each modalities were relatively close, with a difference of 18.5% or less.
    CONCLUSIONS: The two main contributors to the difference in 90Y dosimetry calculations using PET/CT versus PET/MRI can be attributed to the differences in regions of interest (ROIs) and differences attributed to attenuation correction. Due to the superior soft-tissue contrast of MRI, liver contours are usually better seen than in CT images. However, PET/CT provides better quantification of PET images, due to better attenuation correction. In spite of these differences, our results demonstrate that the dosimetry values obtained from PET/MRI and PET/CT in post-therapy 90Y studies were similar.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    BACKGROUND: A major toxicity concern in radioembolization therapy of hepatic malignancies is radiation-induced pneumonitis and sclerosis due to hepatopulmonary shunting of 90Y microspheres. Currently, 99mTc macroaggregated albumin (99mTc-MAA) imaging is used to estimate the lung shunt fraction (LSF) prior to treatment. The aim of this study was to evaluate the accuracy/precision of LSF estimated from 99mTc planar and SPECT/CT phantom imaging, and within this context, to compare the corresponding LSF and lung-absorbed dose values from 99mTc-MAA patient studies. Additionally, LSFs from pre- and post-therapy imaging were compared.
    RESULTS: A liver/lung torso phantom filled with 99mTc to achieve three lung shunt values was scanned by planar and SPECT/CT imaging with repeat acquisitions to assess accuracy and precision. To facilitate processing of patient data, a workflow that relies on SPECT and CT-based auto-contouring to define liver and lung volumes for the LSF calculation was implemented. Planar imaging-based LSF estimates for 40 patients, obtained from their medical records, were retrospectively compared with SPECT/CT imaging-based calculations with attenuation and scatter correction. Additionally, in a subset of 20 patients, the pre-therapy estimates were compared with 90Y PET/CT-based measurements. In the phantom study, improved accuracy in LSF estimation was achieved using SPECT/CT with attenuation and scatter correction (within 13% of the true value) compared with planar imaging (up to 44% overestimation). The results in patients showed a similar trend with planar imaging significantly overestimating LSF compared to SPECT/CT. There was no correlation between lung shunt estimates and the delay between 99mTc-MAA administration and scanning, but off-target extra hepatic uptake tended to be more likely in patients with a longer delay. The mean lung absorbed dose predictions for the 28 patients who underwent therapy was 9.3 Gy (range 1.3-29.4) for planar imaging and 3.2 Gy (range 0.4-13.4) for SPECT/CT. For the patients with post-therapy imaging, the mean LSF from 90Y PET/CT was 1.0%, (range 0.3-2.8). This value was not significantly different from the mean LSF estimate from 99mTc-MAA SPECT/CT (mean 1.0%, range 0.4-1.6; p = 0.968), but was significantly lower than the mean LSF estimate based on planar imaging (mean 4.1%, range 1.2-15.0; p = 0.0002).
    CONCLUSIONS: The improved accuracy demonstrated by the phantom study, agreement with 90Y PET/CT in patient studies, and the practicality of using auto-contouring for liver/lung definition suggests that 99mTc-MAA SPECT/CT with scatter and attenuation corrections should be used for lung shunt estimation prior to radioembolization.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Journal Article
    For phantom studies involving (90)Y PET/CT, homogeneous solutions of (90)Y, for example, (90)Y citrate, are commonly used. However, the microsphere biodistribution of a postradioembolization liver is never homogeneous; therefore, such phantoms are physiologically unrealistic for simulating clinical scenarios. The aim of this work was to develop a safe and practical phantom capable of simulating the heterogeneous microsphere biodistribution of a postradioembolization liver.
    METHODS: Gelatin (5%) was used to suspend (90)Y resin microspheres, poured into plastic containers to simulate a liver with 2 tumors. Microspheres were added while the gelatin was maintained in a liquid state on a hot plate and continuously stirred with magnetic stir bars. The liquid microsphere mixture was then rapidly cooled in an ice bath while being stirred, resulting in a heterogeneous suspension of microspheres. The completed phantom was serially scanned by (90)Y PET/CT over 2 wk.
    RESULTS: All scans demonstrated a heterogeneous microsphere distribution throughout the liver and tumor inserts. Serendipitously, magnetic stir bars left inside the phantom produced CT artifacts similar to those caused by embolization coils, whereas pockets of air trapped within the gelatin during its preparation mimicked gas within hollow viscus. The microspheres and tumor inserts remained fixed and suspended within the gelatin, with no evidence of breakdown or leakage.
    CONCLUSIONS: A gelatin phantom realistically simulating the physiologic microsphere biodistribution of a postradioembolization liver is feasible to construct in a radiopharmacy.