interventional ultrasound

  • 文章类型: Journal Article
    背景:皮质类固醇注射通常用于治疗足底筋膜炎。近年来,文献中已经描述了超声引导下筋膜的多次穿刺治疗。我们的研究旨在比较这两种技术在治疗足底筋膜炎中的有效性。
    方法:检查使用这些技术治疗足底筋膜炎后120天的结果。随机选择81例患者进行研究;41例接受超声引导下的多次穿刺治疗,40例接受超声引导下的皮质类固醇注射治疗。在治疗前和治疗后30、60和120天进行临床检查和超声评估。临床评估包括使用视觉模拟量表(VAS)记录疼痛和使用足部功能指数(FFI)评估功能。超声用于测量足底筋膜的厚度。
    结果:治疗后4个月,超声引导下的多穿刺和皮质类固醇注射技术均与功能和回波图的显着改善相关(P<0.001)。超声引导下皮质类固醇注射120天后疼痛没有明显改善,而超声引导下的多重穿刺可显著减轻疼痛。
    结论:皮质类固醇注射在VAS疼痛和FFI评分方面提供了更好的短期结果。然而,超声引导下的多重穿刺在120日时的VAS疼痛和FFI评分方面显示出优异的结局.
    BACKGROUND: Corticosteroid injections are commonly used for the treatment of plantar fasciitis. In recent years, ultrasound-guided multipuncture treatment of the fascia has been described in the literature. Our study aimed to compare the effectiveness of these two techniques in the treatment of plantar fasciitis.
    METHODS: The outcomes achieved over 120 days following the use of these techniques to treat plantar fasciitis were examined. A total of 81 patients were randomly selected for the study; 41 were treated with ultrasound-guided multipuncture and 40 with ultrasound-guided corticosteroid injection. Clinical examinations and ultrasound assessments were performed before treatment and at 30, 60 and 120 days post-treatment. Clinical assessments included the use of a visual analog scale (VAS) to record pain and the Foot Function Index (FFI) to evaluate function. Ultrasound was used to measure the thickness of the plantar fascia.
    RESULTS: Both the ultrasound-guided multipuncture and corticosteroid injection techniques were associated with significant functional and echographic improvements at 4 months post-treatment (P < 0.001). Pain did not improve significantly after 120 days with ultrasound-guided corticosteroid injection, whereas significant pain reduction was observed with ultrasound-guided multipuncture.
    CONCLUSIONS: Corticosteroid injection provides better short-term results in terms of VAS pain and FFI scores. However, ultrasound-guided multipuncture shows superior outcomes in VAS pain and FFI scores at 120 days.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    幻影和仿真模型是教学和技能提升的宝贵培训工具,然而,高昂的成本和商业选择的局限性推动了对替代品的寻找。这项研究评估了为经阴道和经腹妇科介入超声程序开发的本地来源的体模模型,旨在满足OB-GYN超声专家的教育需求。
    四个体模模型通过经阴道和经腹方法模拟活检和囊肿抽吸/穿刺术,被开发,并由37名妇产科超声专家进行评估。受访者,包括19名经验丰富的人和18名有限接触指导程序的人,利用11项Likert评分问卷评估模型的可接受性和培训适用性。采用描述性统计分析。
    经验丰富和经验不足的组始终都获得高分,特别突出逼真的超声图像和结构的定位。这些模型在基于模拟的探头操作培训中被证明可以有效地增强信心和熟练程度,抽吸,和活检程序。虽然受访者发现了耐用性和针迹痕迹等问题,两组在评估模型方面无显著差异.
    对所开发的幻影模型的总体评估是积极的,展示其在最终用户中的可接受性以及在妇产科中培训超声引导程序的适用性。确定的问题为模型的未来迭代中的潜在改进提供了有价值的见解。
    UNASSIGNED: Phantom and simulation models are valuable training tools for teaching and skill enhancement, yet high costs and limitations of commercial options drive the search for alternatives. This study evaluated the locally sourced phantom models developed for transvaginal and transabdominal gynecologic interventional ultrasound procedures, aiming to cater to the educational needs of OB-GYN ultrasound subspecialists.
    UNASSIGNED: Four phantom models simulating biopsy and cyst aspiration/paracentesis through transvaginal and transabdominal approaches, were developed, and assessed by 37 ultrasound subspecialists in obstetrics and gynecology. The respondents, comprising 19 experienced and 18 with limited exposure to guided procedures, utilized an 11-item Likert-scored questionnaire to evaluate the models\' acceptability and suitability for training. Responses were analyzed using descriptive statistics.
    UNASSIGNED: Both experienced and less-experienced groups consistently assigned high scores, particularly highlighting the realistic ultrasound image and positioning of structures. The models proved effective in enhancing confidence and proficiency during simulation-based training for probe manipulation, aspiration, and biopsy procedures. While respondents identified concerns like durability and needle track marks, no significant differences emerged between the two groups in evaluating the model.
    UNASSIGNED: The overall evaluation of the developed phantom model was positive, showcasing its acceptability among end-users and suitability for training ultrasound-guided procedures in obstetrics and gynecology. The identified issues provide valuable insights for potential improvements in future iterations of the model.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    目的:气坏疽(GG)是一种罕见的严重感染,死亡率很高,主要由梭菌属引起。它突然发展,通常作为腹部手术或肝移植的并发症。我们报告了一例经皮射频消融(RFA)成功治疗的肝细胞癌(HCC)的经皮微波(MW)消融后发生的肝脏GG。
    方法:一名76岁的女性患者接受了VIII段大型HCC的MW消融治疗;2天后出现发热,弱点,腹部肿胀,住院诊断为厌氧性肝脓肿。尽管有抗生素治疗,病人的情况恶化了,她被转移到重症监护病房(ICU)。尝试经皮引流,但没有成功。外科医生和麻醉师排除了任何手术切除的迹象。我们通过3个冷针对感染区域进行了GG的RFA。患者对该手术的耐受性良好,他离开医院接受随访.
    结论:经皮RFA可能是对抗生素难治性患者以及手术和OLT不可行的肝脏局灶性GG的一种有价值的治疗方法。在患者病情迅速恶化的情况下,需要快速和早期的指征。
    OBJECTIVE: Gas gangrene (GG) is a rare severe infection with a very high mortality rate mainly caused by Clostridium species. It develops suddenly, often as a complication of abdominal surgery or liver transplantation. We report a case of GG of the liver occurred after percutaneous microwave (MW) ablation of an hepatocellular carcinoma (HCC) successfully treated with percutaneous Radiofrequency ablation (RFA).
    METHODS: A 76-year-old female patient was treated with MW ablation for a large HCC in the VIII segment; 2 days later she developed fever, weakness, abdominal swelling and was hospitalized with diagnosis of anaerobic liver abscess. Despite antibiotic therapy, the patient conditions worsened, and she was moved to the intensive care unit (ICU). Percutaneous drainage was attempted, but was unsuccessful. The surgeon and the anesthesiologist excluded any indication of surgical resection. We performed RFA of the GG by 3 cool-tip needles into the infected area. The procedure was well tolerated by the patient, who left the hospital for follow-up.
    CONCLUSIONS: Percutaneous RFA could be a valuable therapy of focal GG of the liver in patients refractory to antibiotics and when surgery and OLT are not feasible. A fast and early indication is needed in case of rapid worsening of the patient\'s conditions.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Case Reports
    实时超声引导下的外周插入中心导管(PICC)放置已成为儿童有效获得中心通道的一种有利方法。然而,血流动力学不稳定的小婴儿有很高的并发症风险,需要额外的预防措施.我们介绍了一例在两个月大的扩张型心肌病和失代偿性心力衰竭婴儿中意外动脉放置PICC的情况。当施加的止血带压力超过患者的动脉血压时,在超声检查下区分动脉和静脉有时可能很困难。特别是,对低血压的小孩施加止血带压力很容易损害动脉流量。深入了解上肢血管解剖,基本的扫描技术,特别是对于血流动力学不稳定的小婴儿,细致的准备对于维持该程序的安全性和有效性至关重要。
    Peripherally inserted central catheter (PICC) placement under real-time ultrasound guidance has emerged as a favorable procedure in children as a method to efficiently obtain central access. Nevertheless, small infants with hemodynamic instability are at high risk of complications and extra precautions are necessary. We present a case of an inadvertent arterial placement of a PICC in a two-month-old infant with dilated cardiomyopathy and decompensated heart failure. Differentiation of arteries and veins under ultrasonographic evaluation may sometimes be difficult when the applied tourniquet pressure exceeds the patient\'s arterial blood pressure. In particular, arterial flow can be easily compromised by applying tourniquet pressure in small children with low blood pressure. A thorough understanding of the upper extremity vascular anatomy, basic scanning techniques, and meticulous preparation especially in small infants with hemodynamic instability are essential for maintaining the safety and efficacy of this procedure.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    目的:肩痛是导致患者接受医学评估的主要原因之一。今天,超声(US)是骨科医学中必不可少的工具,风湿病和康复设置,以解决肌肉骨骼疼痛的原因。肩部抱怨的最常见原因之一是频繁的肩峰下慢性滑囊炎(SACB)。在这种情况下,法氏囊壁的增厚以及随后两个滑膜片的融合导致法氏囊壁在肩峰下滑动的相互丧失,从而导致疼痛。这种情况是肩部疼痛的常见原因,肌肉骨骼超声医师可以很容易地解决。本文的目的是描述SACB的US外观,并评估US引导的加氢扩张在其治疗中的疗效。
    方法:我们纳入了在我们的门诊就诊的肩部疼痛患者,这些患者的肩部抱怨诊断为法氏囊壁>1.5mm的SACB。一组通过US引导的加氢扩张治疗,而对照组则通过经典的盲法使用曲安奈德进行治疗。两组在注射后接受相同的康复计划。在基线时通过qDASH问卷评估肩部功能,第3、7、14、30、60和90天。P<0.05被认为是显著的。
    结果:两组均显示疼痛明显减轻;尽管如此,在接受US-加氢扩张治疗的组中,没有必要再治疗。
    结论:美国指导的SACB加氢扩张应该是分离法氏囊壁和改善患者症状的首选技术,因为它需要更少的侵入性操作。
    OBJECTIVE: The shoulder pain is one of the main causes that lead the patient to medical evaluation. Today, the ultrasound (US) represents an essential tool in the orthopaedical, rheumatological and rehabilitative setting to address the musculoskeletal causes of pain. Amongst the commonest causes of shoulder complains lay the frequent subacromial chronic bursitis (SACB). In this condition, the thickening of the bursal walls and subsequent fusion of the two synovial sheets leads to the reciprocal loss of bursal walls gliding under the subacromial space and consequently pain. This condition represents a common cause of shoulder pain and may be easily addressed by musculoskeletal sonographers. The purpose of this paper will be to describe the US appearance of SACB and to evaluate the efficacy of US-guided hydrodilation in its treatment.
    METHODS: We included patients with painful shoulder attending our outpatient clinic for shoulder complains with the diagnosis of SACB with a bursal wall > 1.5 mm. A group was treated via US-guided hydrodilation, while the control group was treated via a classical blind approach using triamcinolone acetonide. Both groups underwent the same rehabilitation program following the injections. The shoulder functionality was assessed via qDASH questionnaire at baseline, days 3, 7, 14, 30, 60, and 90. A p <0.05 was considered significant.
    RESULTS: Both groups displayed a significant reduction of pain; nevertheless, in the group treated with US-hydrodilation, there was no need for re-treatment.
    CONCLUSIONS: The US-guided hydrodilation for SACB should be the preferred technique to detach bursal walls and improve patient symptoms, since it requires fewer invasive maneuvers.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    目的:评估体模和动物实验中基于第五代移动通信技术(5G)的远程机器人超声系统引导经皮穿刺的可行性和安全性。
    方法:在幻影实验中,穿刺了10个模拟病灶,每个病变的两个角度都有一次,在遥控机器人超声系统和超声引导徒手穿刺的指导下。学生t检验用于比较两种方法在穿刺准确性方面,总操作持续时间,和穿刺持续时间。在动物实验中,在远程机器人超声系统的指导下,使用18G穿刺针在肝脏中穿刺3个目标钢珠,右肾,和右臀肌,分别。动物实验无徒手超声引导对照组。穿刺后,进行CT扫描以验证穿刺针相对于目标的位置,并发症和穿刺持续时间,等。,被记录下来。
    结果:在幻影实验中,远程超声引导和常规超声引导下穿刺的平均准确度为1.8±0.3mm和1.6±0.3mm(P=0.09),分别;因此,两种指导方法的准确性没有显着差异。在动物实验中,首次穿刺成功率(针尖接近目标)为93%.一次穿刺时出现呼吸困难。术中、术后无其他并发症发生。
    结论:基于5G的远程机器人超声系统引导下的穿刺在体模和动物实验中显示出良好的可行性和安全性。
    OBJECTIVE: To evaluate the feasibility and safety of percutaneous puncture guided by a 5th generation mobile communication technology (5G)-based telerobotic ultrasound system in phantom and animal experiments.
    METHODS: In the phantom experiment, 10 simulated lesions were punctured, once at each of two angles for each lesion, under the guidance of a telerobotic ultrasound system and ultrasound-guided freehand puncture. Student\'s t test was used to compare the two methods in terms of puncture accuracy, total operation duration, and puncture duration. In the animal experiment, under the guidance of the telerobotic ultrasound system, an 18G puncture needle was used to puncture 3 target steel beads in the liver, right kidney, and right gluteal muscle, respectively. The animal experiment had no freehand ultrasound-guided control group. After puncture, a CT scan was performed to verify the position of the puncture needle in relation to the target, and the complications and puncture duration, etc., were recorded.
    RESULTS: In the phantom experiment, the mean accuracies of puncture under telerobotic ultrasound guidance and conventional ultrasound guidance were 1.8 ± 0.3 mm and 1.6 ± 0.3 mm (P = 0.09), respectively; therefore, there was no significant difference in the accuracy of the two guide methods. In the animal experiment, the first-attempt puncture success (the needle tip close to the target) rate was 93%. Polypnea occurred during one puncture. No other intraoperative or postoperative complications were observed.
    CONCLUSIONS: Puncture guided by a 5G-based telerobotic ultrasound system has shown good feasibility and safety in phantom and animal experiments.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    超声引导电电解技术(USGET)是一种创新的微创干预措施,有可能优化Achille肌腱病(AT)的治疗结果。
    这项初步研究的目的是评估在慢性AT患者的常规偏心运动治疗中添加USGET的疗效。
    纳入标准为单侧非插入性AT患者,疼痛持续>3个月,年龄25-60岁。患者随机分为两组,接受相同的物理治疗(每周2次,共8周)。此外,实验组接受了三次USGET刺激,每15天一次。结果指标是使用维多利亚州运动评估学院(VISA-A)评估跟腱病变的严重程度,并使用视觉模拟量表(VAS)评估疼痛强度。评估点发生在治疗开始时(T0),其结论(T1),随后随访1个月(T2)和2个月(T3)。
    在符合研究纳入标准的52名患者中,两名参与者退出了研究,共有50名受试者完成了这项研究。没有一个参数在T1显示不同的分布(p>0.337)。在T2时,USGET组的VISA-A(p=0.010)及其分量表和VAS(p=0.002)存在统计学差异。在T3时,两组在VISA-A(p<0.001)及其疼痛分量表(p=0.004)中观察到统计学差异,函数(p=0.003)和运动(p=0.002),但EG患者表现出更大的改善。未报告不良事件。
    USGET结合偏心运动的效果似乎是一种安全有效的技术,可在中期内实现疼痛缓解和功能恢复,支持综合使用USGET作为慢性AT患者的康复治疗选择。
    UNASSIGNED: Ultrasound-guided galvanic electrolysis technique (USGET) is an innovative mini-invasive intervention with the potential to optimise outcomes in the treatment of Achille\'s tendinopathy (AT).
    UNASSIGNED: The aim of this pilot study is to evaluate the efficacy of adding USGET to conventional eccentric exercise treatment in patients with chronic AT.
    UNASSIGNED: Inclusion criteria were patients with unilateral non-insertional AT, pain lasting > 3 months, aged 25-60 years. Patients were randomised in two groups receiving the same physiotherapy treatment (2 sessions per week for 8 weeks). In addition, the experimental group received three USGET stimulations, one every 15 days. Outcome measures were assessment of Achilles tendinopathy severity using the Victorian Institute of Sport Assessment-Achilles (VISA-A) and pain intensity using the Visual Analogue Scale (VAS). Assessment points occurred at the onset of treatment (T0), its conclusion (T1), and subsequent follow-ups at one (T2) and two months (T3).
    UNASSIGNED: Out of the 52 patients who met the study inclusion criteria, two participants withdrew from the study, resulting in a total of 50 subjects who completed the research. None of the parameters showed a different distribution at T1 (p> 0.337). At T2, there was a statistical difference in VISA-A (p= 0.010) and its subscales and VAS (p= 0.002) in the USGET group. At T3, both groups improved with a statistical difference observed in VISA-A (p< 0.001) and its subscales Pain (p= 0.004), Function (p= 0.003) and Sport (p= 0.002), but the EG patients showed a greater improvement. No adverse events were reported.
    UNASSIGNED: The effect of USGET combined with eccentric exercise appears to be a safe and effective technique for achieving pain relief and functional recovery in the medium term, supporting the integrated use of USGET as a rehabilitative treatment option for patients with chronic AT.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Randomized Controlled Trial
    背景和目的:局部浸润镇痛(LIA)是减轻全髋关节置换术(THA)患者疼痛的潜在方法。囊周神经组(PENG)阻滞还为骨折和THA提供了足够的镇痛作用。由于大多数髋部手术都使用外侧切口,通过股外侧皮神经(LFCN)的分支影响皮肤供应,LFCN阻滞有助于术后镇痛。然而,没有研究调查补充PENG阻滞联合LFCN阻滞对髋部骨折术后LIA患者的有效性.我们的研究旨在评估PENG联合LFCN阻滞在接受LIA的髋部骨折手术后的有效性。材料与方法:46例患者随机分为LIA或PENG+LFCN+LIA组。主要结果是术后2、6、12、24和48h休息和运动过程中的疼痛评分。还在相同时间点测量了术后镇痛的总阿片类剂量。次要结果包括术后认知功能评估。结果:在整个研究期间,PENG+LFCN+LIA组在休息和运动时的疼痛评分中位数低于LIA组,手术后2小时(休息时)和48小时(运动时)除外。与LIA组相比,PENG+LFCN+LIA组在手术后的所有时间点的总芬太尼剂量较低。两组术后谵妄发生率和中位缩略心理测验评分无显著差异。结论:PENG和LFCN阻滞的组合可能有助于髋部骨折术后LIA患者的康复。然而,需要进一步的良好对照研究来确定补充PENG联合LFCN阻滞在解决这些患者认知缺陷方面的有效性.
    Background and Objectives: Local infiltration analgesia (LIA) represents a potential approach to reducing pain in patients undergoing total hip arthroplasty (THA). The pericapsular nerve group (PENG) block also provides adequate analgesia for fractures and THA. As most hip surgeries use a lateral incision, affecting the cutaneous supply by branches of the lateral femoral cutaneous nerve (LFCN), the LFCN block can contribute to postoperative analgesia. However, no studies have investigated the effectiveness of supplemental PENG block combined with LFCN block in patients undergoing LIA after hip fracture surgery. Our study aimed to assess the effectiveness of PENG combined with LFCN block following hip fracture surgery in patients who underwent LIA. Materials and Methods: Forty-six patients were randomly assigned to LIA or PENG + LFCN + LIA groups. The primary outcome was the pain score at rest and during movement at 2, 6, 12, 24, and 48 h postoperatively. The total opioid dose for postoperative analgesia was also measured at the same time points. Secondary outcomes included postoperative cognitive function assessment. Results: The median pain scores at rest and during movement were lower in the PENG + LFCN + LIA group throughout the study periods compared to the LIA group, except at 2 h (at rest) and 48 h (during movement) after surgery. The total fentanyl dose was lower in the PENG + LFCN + LIA group at all time points after surgery when compared to the LIA group. Postoperative delirium incidence and the median abbreviated mental test scores were not significantly different between the two groups. Conclusions: The combination of PENG and LFCN blocks may contribute to enhanced recovery for patients undergoing LIA after hip fracture surgery. However, further well-controlled research is necessary to determine the effectiveness of supplemental PENG combined with LFCN block in addressing cognitive deficits in these patients.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Review
    即时超声检查(POCUS)的使用不仅限于危重病人的诊断和/或监测。Further,超声引导对于帮助在重症监护病房(ICU)中成功和安全地执行多种程序至关重要。在这篇文章中,我们回顾了POCUS在ICU中作为程序性指导的作用.核心程序包括,但不限于,血管插管术,心包穿刺术,胸腔穿刺术,穿刺术,软组织收集物/关节穿刺术和腰椎穿刺抽吸。随着时间的推移,强化医师执行的程序可能超出本综述中描述的核心能力。超声引导应该是强化医生能力的一部分,应该进行适当的培训。
    The use of point-of-care ultrasonography (POCUS) is not limited to the diagnosis and/or monitoring of critically ill patients. Further, ultrasound guidance is of paramount relevance to aid in successfully and safely performing several procedures in the intensive care unit (ICU). In this article, we review the role of POCUS as a procedural guidance in the ICU. Core procedures include, but are not limited to, vascular cannulation, pericardiocentesis, thoracentesis, paracentesis, aspiration of soft-tissue collections/arthrocentesis and lumbar puncture. With time, the procedures performed by intensivists may extend beyond the core competencies depicted in this review. Ultrasound guidance should be part of the intensivist\'s competencies, for which appropriate training should be achieved.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    自1960年代后期以来,甲状腺的超声(US)已被用作诊断工具。US是诊断甲状腺疾病最重要的影像学工具。在大多数情况下,可以通过超声检查的概要以及临床发现和基础甲状腺激素参数进行正确的诊断。然而,US对甲状腺结节的定性仍具有挑战性.甲状腺成像报告和数据系统(TIRADS)的引入显着提高了甲状腺癌的诊断准确性。较新的技术,如弹性成像,精湛的微血管成像(SMI),超声造影(CEUS)和多参数超声(MPUS)进一步扩展了诊断选项和工具。此外,人工智能(AI)的使用是改善和简化甲状腺结节诊断的有前途的工具,并且有证据表明AI可以超过人类的表现。将不同的美国技术与新软件的引入相结合,使用AI,FNB以及分子标志物可能为甲状腺疾病诊断准确性的全新领域铺平道路。最后,越来越多地提出使用US引导的热消融(TA)程序作为良性和恶性甲状腺疾病的治疗选择。
    Ultrasound (US) of the thyroid has been used as a diagnostic tool since the late 1960s. US is the most important imaging tool for diagnosing thyroid disease. In the majority of cases a correct diagnosis can already be made in synopsis of the sonographic together with clinical findings and basal thyroid hormone parameters. However, the characterization of thyroid nodules by US remains challenging. The introduction of Thyroid Imaging Reporting and Data Systems (TIRADSs) has improved diagnostic accuracy of thyroid cancer significantly. Newer techniques such as elastography, superb microvascular imaging (SMI), contrast enhanced ultrasound (CEUS) and multiparametric ultrasound (MPUS) expand diagnostic options and tools further. In addition, the use of artificial intelligence (AI) is a promising tool to improve and simplify diagnostics of thyroid nodules and there is evidence that AI can exceed the performance of humans. Combining different US techniques with the introduction of new software, the use of AI, FNB as well as molecular markers might pave the way for a completely new area of diagnostic accuracy in thyroid disease. Finally, interventional ultrasound using US-guided thermal ablation (TA) procedures are increasingly proposed as therapy options for benign as well as malignant thyroid diseases.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文