Synergistic disinfection

  • 文章类型: Journal Article
    水再生厂(WRP)面临着确保微生物安全的挑战,需要有效的消毒系统。顺序臭氧-氯消毒被认为是再生水消毒的有利替代方案。本研究比较了单一臭氧对大肠杆菌的灭活效率,单氯,和顺序臭氧氯消毒方法。值得注意的是,单一的臭氧或氯工艺只能实现高达5对数的对数去除率,而顺序的臭氧-氯消毒可以完全灭活微生物(7.3log)。对于顺序臭氧-氯消毒,氯化效率提高了2.4%-18.5%。协同效应主要归因于臭氧消除了氯消耗物质。通过对氯衰变模型(CRS)的拟合和计算积分CT值,量化了臭氧对氯消毒的增强能力。通过引入增强系数(β),建立了一个简洁准确的模型来估算顺序臭氧氯消毒的失活率(平均绝对百分比误差:0.035)。这项研究的结果和方法可为优化WRP的消毒单位提供信息。
    Water reclamation plants (WRPs) are facing the challenges of ensuring microbial safety and require efficient disinfection systems. Sequential ozone‑chlorine disinfection is supposed to be a favorable alternative for reclaimed water disinfection. This study compared the inactivation efficiency of E.coli by single ozone, single chlorine, and sequential ozone‑chlorine disinfection approaches. Notably, a single ozone or chlorine process could only achieve a log removal rate of up to 5 log, whereas the sequential ozone‑chlorine disinfection could completely inactivate microorganisms (7.3 log). For sequential ozone‑chlorine disinfection, the efficiency of chlorination was improved by 2.4%-18.5%. The synergistic effect mainly attributed to the elimination of chlorine consuming substances by ozone. Through the chlorine decay model (CRS) fitting and calculating the integral CT value, the enhancement ability of ozone to chlorine disinfection was quantified. By introducing an enhancement coefficient (β), a succinct and accurate model was established to estimate the inactivation rate of sequential ozone‑chlorine disinfection (mean absolute percentage error: 0.035). The results and methodology of this study are informative to optimize the disinfection units of WRPs.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Disinfection of secondary effluents is vital to provide a sustainable aquatic environment, minimize microbial risks and guarantee public and environmental safety. This study investigated the effectiveness of six treatment trains including single and combined disinfection processes (i.e., ozone alone, ultraviolet (UV) irradiation alone, chlorine alone, sequential ozone-UV, sequential ozone-chlorine and sequential ozone-UV-chlorine) on bacterial inactivation, as well as bulk water quality parameters such as color, turbidity, absorbance at 254 nm (UV254), dissolved organic carbon (DOC) and fluorescence based on samples collected from an actual water reclamation plant (WRP). For the single disinfection processes, when the ozone, UV and chlorine doses reached 5 mg/L, 15 mJ/cm2 and 4 mg/L, respectively, the log removal of Escherichia coli (E. coli) reached 5 log. A trailing phenomenon was observed with further increases in the disinfectant dosage. Under the combined treatment scenarios, ozone pretreatment resulted in substantial removal of color, turbidity, UV254, fluorescence excitation-emission matrix (FEEM) and chlorine consuming organics, thus enhancing the efficiency of subsequent UV irradiation or chlorine treatments. In the sequential ozone-UV-chlorine experiments, E. coli inactivation reached 7 log with ozone, UV and available chlorine of 3 mg/L, 5 or 10 mJ/cm2 and 2.5 mg/L, respectively. On the basis of the results from the actual WRP, the estimated operating cost per unit for the disinfection systems is 0.065 CNY/t, which is economical for long-term operation.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号