test validation

测试验证
  • 文章类型: Journal Article
    虽然HC2和GP5+/6+PCR-EIA在新HPV检测的测试验证中至关重要,它们代表了基于不再广泛使用的技术的第一代比较器测试。在目前的指导方针中,提供了第二代比较试验的标准,包括更详细的HPV基因型分辨率.第二代比较测试应优先仅针对被归类为致癌的12种基因型(IARC-I组)。与第一代比较者之一相比,对CIN2+和CIN3+的敏感性一致,对≤CIN1的特异性一致,在至少3项验证研究中,相对灵敏度为0.95,相对特异性为0.98.验证应考虑使用过的存储介质和其他样品处理程序。进行荟萃分析以鉴定满足这些严格标准的测定。四项检测符合新标准:(1)实时高危型HPV检测(雅培),(2)Cobas-4800HPV检测(罗氏分子系统),(3)清净度HPV测定(BD诊断),和(4)AnyplexIIHPVHR检测(Seegene),在3至6项研究中进行了评估。而四种检测方法针对14种致癌基因型,前两个分别鉴定HPV16和18,第三个测定分别鉴定五种类型,第四个测定分别鉴定所有类型。
    While HC2 and GP5+/6+ PCR-EIA were pivotal in test validation of new HPV assays, they represent the first generation of comparator tests based upon technologies that are not in widespread use anymore. In the current guideline, criteria for second-generation comparator tests are presented that include more detailed resolution of HPV genotypes. Second-generation comparator tests should preferentially target only the 12 genotypes classified as carcinogenic (IARC-group I), and show consistent non-inferior sensitivity for CIN2+ and CIN3+ and specificity for ≤CIN1 compared to one of the first-generations comparators, in at least three validation studies using benchmarks of 0.95 for relative sensitivity and 0.98 for relative specificity. Validation should take into account used storage media and other sample handling procedures. Meta-analyses were conducted to identify the assays that fulfill these stringent criteria. Four tests fulfilled the new criteria: (1) RealTime High-Risk HPV Test (Abbott), (2) Cobas-4800 HPV test (Roche Molecular System), (3) Onclarity HPV Assay (BD Diagnostics), and (4) Anyplex II HPV HR Detection (Seegene), each evaluated in three to six studies. Whereas the four assays target 14 carcinogenic genotypes, the first two identify separately HPV16 and 18, the third assay identifies five types separately and the fourth identifies all the types separately.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    Only clinically validated human papillomavirus (HPV) tests should be used in cervical cancer screening. VALGENT provides a framework to validate new HPV tests. In the VALGENT-3 study, the clinical accuracy of the recently launched Abbott Alinity m HR HPV assay (Alinity m) to detect cervical precancerous lesions was assessed against the standard comparator test (Hybrid Capture 2; HC2) and against two previously validated alternative comparator tests (Abbott RealTime HR HPV and Roche cobas 4800 assays). Validation was conducted using 1,300 consecutive cervical samples from women attending an organized population-based cervical screening program enriched with 300 cytologically abnormal samples. Overall high-risk HPV test concordance was assessed by kappa values; the concordance for HPV-16 and HPV-18 was assessed for Alinity m, RealTime, and cobas, and the Linear Array (Roche) was used for more detailed genotyping concordance. In the total study population, the relative sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse (CIN2+) and CIN3+ of Alinity m compared to HC2 was 1.02 (95% confidence interval [CI], 0.99 to 1.06) and 1.03 (95% CI, 0.99 to 1.06), respectively. The relative specificity for nondiseased subjects (≤CIN1) was 1.01 (95% CI, 1.00 to 1.02) (all p non-inferiority ≤ 0.001). Alinity m showed noninferior clinical accuracy among women 30 years or older when cobas or RealTime was used as a comparator. HPV genotype-specific concordance between Alinity m and the three comparator tests showed excellent agreement, with kappa values ranging from 0.82 to 1.00. In conclusion, Alinity m fulfills the international accuracy requirements for use in cervical cancer screening and shows excellent HPV genotype-specific concordance with three clinically validated HPV tests.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    Systematic reviews have concluded that hrHPV DNA testing using target-amplification tests is as accurate on vaginal self-samples as on clinician-taken specimens for the detection of cervical precancer. However, insufficient evidence is available for specific HPV assay/self-sample device combinations.
    The VALHUDES protocol is designed as a diagnostic test accuracy study that aims to compare the clinical sensitivity and specificity of particular hrHPV assay(s) on vaginal self-samples and first-void-urine, collected in agreement with standardized protocols, with hrHPV testing on matched clinician-taken samples.
    Five hundred enrolled women referred to a colposcopy clinic are invited to collect a first-void urine sample and one or more vaginal self-samples with particular devices before collection of a cervical sample by a clinician. Sample sets are subsequently analysed in a laboratory accredited for HPV testing. Disease verification for all enrolled patients is provided by colposcopy combined with histological assessment of biopsies.
    A first VALHUDES study has started in Belgium in December 2017 with enrolment from four colposcopy centres. The following assays are foreseen to be evaluated: RealTime High Risk HPV assay (Abbott), cobas-4800 and -6800 (Roche), Onclarity (BD), Xpert HPV (Cepheid) and Anyplex II HPV HR (Seegene).
    Given empirical evidence that the relative accuracy of HPV-testing on self- vs clinician-samples is robust across clinical settings, the VALHUDES protocol offers a framework for validation of HPV assay/self-sample device combinations that can be translated to a primary screening setting.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号