clinical tests

临床测试
  • 文章类型: Journal Article
    Purpose: To investigate to what extent the OSDI can be utilized as a discriminative test for clinical findings. Methods: One thousand and ninety patients with dry eye disease (DED) were consecutively included and examined for osmolarity, tear film break-up time (TFBUT), ocular protection index (OPI), ocular surface staining (OSS), Schirmer I test (ST), meibum expressibility (ME), meibum quality (MQ), and diagnosis of meibomian gland dysfunction (MGD). Receiver-operating characteristic curve (ROC) analysis considering optimum balanced sensitivity and specificity (close to 50%) was used for assessment. Results: The present study on more than 1,000 patients indicates that the OSDI in the ROC curve analysis is a poor discriminator of pathological scores for TFBUT ≤ 5 (AUC = 0.553; p = .012) and ≤10 s (AUC = 0.608; p = .002), OSS ≥ 3 (AUC = 0.54; p = .043), ST ≤ 5 (AUC = 0.550; p = .032) and ≤10 mm/5 min (AUC = 0.544; p = .016), and ME ≥ 1 (AUC = 0.594; p = <0.001). Pathological scores for osmolarity >308 and >316 mOsm/L, OPI, OSS > 1, MQ, and MGD could not be discriminated by OSDI (p > .05). Conclusion: Cut-off values for the OSDI can be defined to discriminate pathological TFBUT (≤5 and ≤10), OSS (≥3), ST (≤5 and ≤10) and ME, however, the discriminability was low. Our comprehensive study emphasises the importance of taking both symptoms and signs into account in DED management.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    BACKGROUND: The distal radius fracture is one of the common clinical fractures. At present, there are no reports regarding application of the finite element method in studying the mechanism of Colles fracture and the biomechanical behavior when using splint fixation.
    OBJECTIVE: To explore the mechanism of Colles fracture and the biomechanical behavior when using different fixed splints.
    METHODS: Based on the CT scanning images of forearm for a young female volunteer, by using model construction technology combined with RPOE and ANSYS software, a 3-D distal radius fracture forearm finite element model with a real shape and bioactive materials is built. The material tests are performed to obtain the mechanical properties of the paper-based splint, the willow splint and the anatomical splint. The numerical results are compared with the experimental results to verify the correctness of the presented model. Based on the verified model, the stress distribution of different tissues are analyzed. Finally, the clinical tests are performed to observe and verify that the anatomical splint is the best fit for human body.
    RESULTS: Using the three kinds of splints, the transferred bone stress focus on the distal radius and ulna, which is helpful to maintain the stability of fracture. Also the stress is accumulated in the distal radius which may be attributed to flexion position. Such stress distribution may be helpful to maintain the ulnar declination. By comparing the simulation results with the experimental observations, the anatomical splint has the best fitting to the limb, which can effectively avoid the local compression.
    CONCLUSIONS: The anatomical splint is the most effective for fixing and curing the fracture. The presented model can provide theoretical basis and technical guide for further investigating mechanism of distal radius fracture and clinical application of anatomical splint.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Comparative Study
    The laryngeal mask airway (LMA) is a supraglottic device that is commonly used to provide lung ventilation during general anesthesia. LMA placement needs to be confirmed to provide adequate lung ventilation. To investigate the feasibility of using ultrasound examination, compared with clinical tests and fiberoptic laryngoscopy, to confirm LMA placement, we performed a clinical study of 64 female patients classified as American Society of Anesthesiologists Physical Status I or II who were scheduled for gynecologic surgery with LMA insertion for airway management. After insertion, placement of the LMA was confirmed by clinical tests, ultrasound examination and fiberoptic laryngoscopy. Of the 64 women, placement was confirmed as acceptable in 89.1% by clinical tests, in 59.4% by fiberoptic laryngoscope assessment and in 67.2% by ultrasound examination. With respect to patients with oropharyngeal leaks classified as high, there were no differences in confirmation of acceptable placement between clinical tests and ultrasound examinations (p = 0.092), but the number of patients determined to have acceptable placement by ultrasound examination was greater than that determined by fiberoptic laryngoscopy (p = 0.034). Thus, ultrasound examination is a superior technique for confirming the seal on the LMA.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号