vision testing

  • 文章类型: Systematic Review
    背景:视敏度(VA)测试是评估眼功能的重要筛查工具。2019年冠状病毒大流行导致所有专业都迫切需要同步远程医疗,包括眼科.虽然存在过多的移动VA应用程序,关于什么技术可以准确和可重复地在家中测量患者的视力,目前还没有共识。
    方法:于2020年4月使用PubMed进行了系统的文献检索,Embase和Medline,确定2010年至2020年远程VA测试的英文出版物:4338篇文章被确定,14篇最终纳入审查。
    结果:在这14项质量最高的研究中,使用PeekAcuity应用程序发现了最佳的可重复性和与临床视力的相关性。这些研究包括世界各地3-97岁的患者,有或没有矫正,具有已知的眼部病理学。PeekAcuity研究在三星GalaxyS3上测量了远距视力,与早期治疗糖尿病视网膜病变研究(ETDRS)相比,家庭测试的最小分辨率角度(LogMAR)的平均差为0.055。95%置信区间界限的重测变异性为±0.029LogMAR。
    结论:在使用参考标准ETDRS和临床标准Snellen图表的临床环境中,视力测试可以有一个或多个变化线。即使在标准临床图表上,重测可靠性也不完美(变化高达0.48LogMAR)。在审查的技术中,PeekAcuity家庭测试与ETDRS临床视力和高重测可靠性具有最大的相关性。PeekAcuity的表现并不比Snellen和ETDRS图表差。
    BACKGROUND: Visual acuity (VA) testing is a vital screening tool for the assessment of ocular function. The coronavirus 2019 pandemic has caused an immediate need for synchronous telemedicine in all specialties, including ophthalmology. While a plethora of mobile VA applications exist, there is no consensus as to what technology can accurately and reproducibly measure a patient\'s vision at home.
    METHODS: A systematic literature search was performed in April 2020 using PubMed, Embase and Medline, identifying English publications from 2010 to 2020 on remote VA tests: 4338 articles were identified and 14 were ultimately included in the review.
    RESULTS: Of those 14, the highest quality studies, best reproducibility and correlation with in-clinic acuities measured were found using the Peek Acuity application. The studies included patients throughout the world aged 3-97, with and without correction, with known ocular pathology.The Peek Acuity studies measured distance vision on a Samsung Galaxy S3 with a mean difference of 0.055 Logarithm of the Minimum Angle of Resolution (LogMAR) for home testing compared with the Early Treatment Diabetic Retinopathy Study (ETDRS). Test-retest variability was ±0.029 LogMAR for 95% confidence interval limits.
    CONCLUSIONS: There can be one or more lines of variability in vision testing in a clinical setting using reference standard ETDRS and clinical standard Snellen charts. Test-retest reliability is not perfect even on standard clinical charts (variation up to 0.48 LogMAR). Of the technologies reviewed, Peek Acuity home testing had the greatest correlation with ETDRS clinical vision and high test-retest reliability. Peek Acuity performed no worse than Snellen and ETDRS charts.