patent blue

  • 文章类型: Case Reports
    BACKGROUND: Intoxication with Patent Blue V [sodium compound of (diethylamino-4-phenyl)(hydroxy-5-disulfo-2,4-phenyl) methanol] can lead to high levels of methemoglobin and metabolic acidosis. In severe cases and if not rapidly eliminated from the plasma, this can lead to multiple organ failure and death.
    METHODS: A 27-year-old Asian woman (original from Vietnam) was admitted after ecstasy intoxication resulting in multi-organ failure (acute respiratory distress syndrome, metabolic acidosis, capillary leakage syndrome, renal failure, shock refractory to standard resuscitation). As a consequence, continuous renal replacement therapy and veno-venous extracorporeal membrane oxygenation were started. Methylene blue administration to reverse vasoplegia was decided, but unfortunately, Patent Blue V was erroneously administered, resulting in a severe clinical picture of methemoglobinemia and tissue hypoxia. As a therapeutic intervention, CytoSorb hemoadsorption was initiated, and rapid and significant reduction in plasma methemoglobin, accompanied by improved hemodynamics and normalization in plasma lactate levels, was observed.
    CONCLUSIONS: This is the first case describing the application of CytoSorb hemoadsorption in a patient with ecstasy intoxication complicated by iatrogenic administration of Patent Blue V. There is a potential role for CytoSorb in drug intoxication, which needs to be confirmed in larger series.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Case Reports
    暂无摘要。
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    Intraoperative search for the sentinal node using patent blue is considered a non risk procedure. We emphasize the highly exceptional nature of this adverse effect previously observed in other disciplines using this coloring agent. We present a case of allergic reaction to patent blue in a patient who underwent left mastectomy with sentinel lymph node. About 25 min after the dye injection, the patient developed increased heart frequency and allergic skin reaction. The patient was treated successfully with decreased inspired fraction of inhaled anesthetic and fluid replacement. The patient recovered uneventfully and was discharged from the PACU 3h after the end of surgery without skin changes and was discharged from hospital on the morning after surgery. Allergic reactions with the use of patent blue are far superior to the hypersensitivity reactions seen with anesthetic and adjuvant drugs. Therefore, the anesthesiologist must be aware of cardiovascular instability associated with skin changes during the use of patent blue, for early diagnosis and appropriate treatment of this hypersensitivity reaction to this dye. Skin tests done later confirmed allergy to patent blue dye; the tests induced a small syndrome reaction. Surgical personnel who use patent blue dye should be made aware of the risk of allergic reactions, sometimes severe, to this dye.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

       PDF(Pubmed)

  • 文章类型: Case Reports
    我们介绍了一名接受前哨淋巴结切除术并与节段性乳房切除术相关的患者对专利蓝的过敏反应。染料注射后约20min,患者出现低血压(BP=70×30mmHg),并伴有心率增加.通过减少吸入麻醉药的吸入比例和液体置换,成功治疗了患者。在程序结束时,她头上出现了蓝色的荨麻疹状斑块,脖子,上肢,和树干;然后使用氢化可的松。患者恢复顺利,手术结束后2h从PACU出院,皮肤无变化,手术后早上出院。使用专利蓝的过敏反应的发生率远远优于麻醉和辅助药物的超敏反应。因此,麻醉师必须意识到在使用专利蓝期间与皮肤变化相关的心血管不稳定,用于对这种染料的超敏反应的早期诊断和适当治疗。
    We present a case of allergic reaction to patent blue in a patient who underwent excision of sentinel lymph node associated with segmental breast resection. About 20min after the dye injection, the patient developed hypotension (BP=70×30mmHg) associated with increased heart frequency. The patient was treated successfully with decreased inspired fraction of inhaled anesthetic and fluid replacement. At the end of the procedure, she presented with bluish urticarial-like plaques on the head, neck, upper limbs, and trunk; hydrocortisone was then used. The patient recovered uneventfully and was discharged from the PACU 2h after the end of surgery without skin changes, and was discharged from hospital on the morning after surgery. The incidence of allergic reactions with the use of patent blue is far superior to the hypersensitivity reactions seen with anesthetic and adjuvant drugs. Therefore, the anesthesiologist must be aware of cardiovascular instability associated with skin changes during the use of patent blue, for early diagnosis and appropriate treatment of this hypersensitivity reaction to this dye.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: English Abstract
    We present a case of allergic reaction to patent blue in a patient who underwent excision of sentinel lymph node associated with segmental breast resection. About 20minutes after the dye injection, the patient developed hypotension (BP=70×30mmHg) associated with increased heart frequency. The patient was treated successfully with decreased inspired fraction of inhaled anesthetic and fluid replacement. At the end of the procedure, she presented with bluish urticarial - like plaques on the head, neck, upper limbs, and trunk; hydrocortisone was then used. The patient recovered uneventfully and was discharged from the PACU two hours after the end of surgery without skin changes, and was discharged from hospital on the morning after surgery. The incidence of allergic reactions with the use of patent blue is far superior to the hypersensitivity reactions seen with anesthetic and adjuvant drugs. Therefore, the anesthesiologist must be aware of cardiovascular instability associated with skin changes during the use of patent blue, for early diagnosis and appropriate treatment of this hypersensitivity reaction to this dye.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

公众号