orbital prosthesis

眼眶假体
  • 文章类型: Journal Article
    本系统综述旨在收集CAD/CAM技术在颅面植入物放置术前计划中的技术和临床应用。模具和子结构的设计以及轨道假体的制造。遵循系统审查和荟萃分析(PRISMA)指南的首选报告项目,进行了电子搜索。包括利用数字规划系统进行眼眶缺损修复的人体研究。共16项研究,共30例临床病例,实际上是通过各种数字规划和设计软件进行规划的,包括在内。数字计划所需的最常见的术前数据是15例CT扫描,3DSS-STD-II扫描系统5例,ArtecColor3D扫描仪3例,NextEngineDesktop3D激光扫描仪2例。同时,数字设计软件是Ease轨道植入计划EOIPlan软件,在八个案例中,Geomagic软件在八个案例中,植入软件有4例,ArtecStudio12Professional有3例。为12例患者制作手术模板,在眼眶缺损区放置41个颅面植入物。在两种情况下,使用图像引导的手术导航系统放置了五个眼眶植入物。据报道,数字设计和打印系统用于颅面植入物放置的术前计划,模具和子结构的设计以及轨道假体的制造。研究得出的结论是,数字规划,眼眶假体的设计和制造减少了临床和实验室时间,减少患者就诊次数并提供令人满意的结果;然而,技术技能和设备成本对这些数字系统的使用构成了限制。
    This systematic review was aimed at gathering technical and clinical applications of CAD/CAM technology for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, an electronic search was executed. Human studies that utilized digital planning systems for the prosthetic rehabilitation of orbital defects were included. A total of 16 studies of 30 clinical cases, which were virtually planned through various digital planning and designing software, were included. The most common preoperative data required for digital planning were CT scans in 15 cases, the 3DSS-STD-II scanning system in 5 cases, an Artec Color 3D scanner in 3 cases and a NextEngine Desktop 3D laser scanner in 2 cases. Meanwhile, the digital designing software were Ease Orbital Implant Planning EOIPlan software in eight cases, Geomagic software in eight cases, Simplant software in four cases and Artec Studio 12 Professional in three cases. Surgical templates were fabricated for 12 cases to place 41 craniofacial implants in the orbital defect area. An image-guided surgical navigation system was utilized for the placement of five orbital implants in two cases. Digital designing and printing systems were reported for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. The studies concluded that the digital planning, designing and fabrication of orbital prostheses reduce the clinical and laboratory times, reduces patient visits and provide a satisfactory outcome; however, technical skills and equipment costs are posing limitations on the use of these digital systems.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Pubmed)

  • 文章类型: Journal Article
    OBJECTIVE: To describe clinical and histopathologic pre-operative diagnoses as well as associated post-operative complications following orbital silicone implantation in dogs undergoing enucleation and evaluate owner satisfaction.
    METHODS: One hundred and eighty-six dogs who underwent enucleation with orbital implant.
    METHODS: Medical records from dogs that underwent enucleation with orbital implant performed at Virginia-Maryland Veterinary Teaching Hospital between 2007 and 2019 were reviewed. Owners were surveyed via telephone regarding client satisfaction.
    RESULTS: Enucleation followed by orbital implant placement occurred in 215 eyes of 186 dogs. The most common pre-operative diagnoses were glaucoma (68.8%), uveitis (17.7%), cataracts (15.8%), intraocular neoplasia (13.0%), and lens luxation (10.7%). The most common histopathologic diagnoses were retinal degeneration (46.5%), uveitis (39.5%), cataract (29.8%), retinal detachment (27.4%), and secondary glaucoma (26.5%). Fourteen eyes (6.5%) from ten dogs had post-operative complications reported including orbit cellulitis (n = 11), implant migration (n = 1), and implant extrusion (n = 1). Five of these dogs (50%) had concurrent diabetes mellitus. Median complication time from surgery was 41 days (range: 11-541 days). Ninety-five owner survey responses were completed with a median time of 6.3 years following surgery. Most owners, 85.3% (n = 81), were satisfied with the post-operative outcome.
    CONCLUSIONS: Enucleation with implantation of an orbital implant is a viable and safe method for irreversibly blind eyes. Diabetes mellitus may be a risk factor for the development of post-operative complications. Intraocular neoplasia was not associated with development of post-operative complications. Results of this study indicated high owner satisfaction rates for improving cosmetic appearance after enucleation in dogs.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    暂无摘要。
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    OBJECTIVE: To determine the changes in indications for orbital exenteration over 20 years and to assess its impact on patient survival. Evolving techniques of rehabilitation of the orbit in our institution were also evaluated.
    METHODS: This was a retrospective review of hospital records of patients who underwent orbital exenteration from 1995 to 2015 in a tertiary care center. Data extracted included primary location of the tumor, preoperative treatments, interval between initial diagnosis and exenteration, status of surgical margins, presence of metastatic disease, and postoperative survival. The types of prosthesis utilized over the years were also reviewed. Cox regression analysis was performed for categorical variables. Kaplan-Meier analysis was used to estimate post-exenteration survival.
    RESULTS: Over a 20-year period, orbital exenteration was performed on 100 orbits of 100 patients. The mean age was 39.4 years (range: 2 months to 90 years). The most common indications among 98 malignant causes were retinoblastoma, squamous cell carcinoma, basal cell carcinoma, extraocular extension of uveal melanoma, and conjunctival melanoma. Postoperative survival was significantly related to age and tumor location but independent from gender, surgical margin, histopathological diagnosis, previous treatment modality, and preoperative interval. In the whole cohort, 1-year and 5-year survival rates were 97% and 84%, respectively.
    CONCLUSIONS: Exenteration appears to be life-saving in children with orbital extension of retinoblastoma. While patients exenterated for malignant eyelid tumors have the best chance of survival, those with orbital extension of uveal melanoma and adenoid cystic carcinoma of the lacrimal gland have the worst prognosis.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    暂无摘要。
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • 文章类型: Journal Article
    In this paper, a computer-aided system for orbital prosthesis rehabilitation is introduced. With the system, a 3D model of the orbital prosthesis can be easily reconstructed from the CT image of a patient by referring to the normal eye of the patient, and the rehabilitation result by the model can be simulated before the surgery. This facilitates surgeons to design appropriate orbital prosthesis and improve rehabilitation esthetics. Based on the system, the preoperative surgery planning for orbital implant can also be made. This improves the reliability, safety and intuition of the rehabilitation surgery well. The system has been applied to clinical CT images of patients, and the experimental results show effectiveness and acceptability of the system in the clinic.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    使用硅胶假体修复眼眶缺损已成为有据可查且公认的治疗选择。粘合剂保留的假体为患者提供了足够的保留和治疗满意度。然而,边缘击穿和变色是与这些假体相关的常见问题,需要他们的翻新。硅酮眼眶假体的制造是耗时的并且需要多个临床和实验室程序。该技术文章描述了使用常规方法快速制造硅酮假体的简单且成本有效的步骤。
    Restoration of orbital defects with silicone prosthesis has been a well-documented and accepted treatment option. Adhesive retained prosthesis offer the patients with adequate retention and treatment satisfaction. However, marginal breakdown and discoloration are common problems associated with these prostheses, necessitating their refabrication. Fabrication of a silicone orbital prosthesis is time consuming and requires multiple clinical and laboratory procedures. This technical article describes simple and cost effective steps for rapid fabrication of a silicone prosthesis using conventional methods.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Case Reports
    Diminution of the orbital contents post-surgical removal of a malignant tumor can have a severe psychological impact on the patient in terms of function and esthetics. Therefore, esthetic remedy should be planned subsequently, since tumor obliteration precedes cosmetic concern. A convenient option for successful rehabilitation in such patients is a simple, user-friendly, removable orbital prosthesis. Retention of the prosthesis is one of the key factors for the successful rehabilitation. Spectacle frame, conformers, adhesives, osseointegrated implants, magnets or buttons have been used to impart retention to the prosthesis. The use of semi precision attachments in maxillofacial prostheses is limited to the osseointegrated prostheses. This case report describes a conventional spectacle frame technique, to retain the silicone orbital prosthesis using two different types of stud attachments viz., dalla bona and O-ring attachment systems.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    The Tessier number 5 cleft is a rare craniofacial anomaly. Although there are case reports outlining various methods of primary surgical repair and outcomes, few cases reveal long-term follow-up or discuss secondary reconstruction. This article presents the case of a man born with a unilateral Tessier number 5 cleft who presented to our institution at the age of 41 after more than 25 previous surgeries. Over the course of 11 years, he had several surgeries including an orbital repositioning through a combined intra- and extracranial approach, an orbital enucleation, and an anterolateral thigh flap. The patient was fitted with an orbital prosthesis and a satisfactory aesthetic result was achieved.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

  • DOI:
    文章类型: Journal Article
    This report describes a different approach for diminishing the movements of orbital prosthesis during mimic movements and chewing function. Mechanical devices such as magnets are used to enhance the retention in case lack of the implants. However rigid fixation of obturator and orbital prosthesis can result in movements of the orbital prosthesis during mastication. In this case obturator and orbital prosthesis are combined by magnets. However this combination is not rigid because of an active part which provides movement. This active part allows movements in a space constructed in the acrylic base of orbital prosthesis. Thus, the movements that may occur on orbital prosthesis during chewing can be diminished by this simple mechanism. Due to the fact that designing such a mechanism that minimizes the movements of the orbital prosthesis contributes patient\'s comfort.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号