cooling towers

  • 文章类型: Journal Article
    This study aimed to investigate for the first time the in vitro antibiofilm effectiveness of two chloramphenicol liposome formulations against biofilms of potentially pathogenic bacteria associated to corrosion isolated from the water of cooling towers from a Brazilian industry. Antibiofilm assays with liposomes were performed in 96-wells microtiter plates, and data was compared to free chloramphenicol treatment. Chloramphenicol-loaded liposomes were successfully produced using the dehydration-rehydration method, with vesicle diameters of 131 nm (100 nm membrane extrusion) and 182 nm (200 nm membrane extrusion) assessed by dynamic light scattering. The liposomes obtained by 100 nm membrane extrusion were more effective than 200 nm membrane extrusion vesicles against the biofilms after overnight exposure, and the free drug had no antibiofilm effect. Our study open doors for more investigations on liposome entrapment of antimicrobial compounds such as biocides of industrial use, for controlling biofilm formation in aquatic environments.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

       PDF(Sci-hub)

  • 文章类型: Journal Article
    Between 1 August and 6 September 2013, an outbreak of Legionnaires\' disease (LD) with 159 suspected cases occurred in Warstein, North Rhine-Westphalia, Germany. The outbreak consisted of 78 laboratory-confirmed cases of LD, including one fatality, with a case fatality rate of 1%. Legionella pneumophila, serogroup 1, subtype Knoxville, sequence type 345, was identified as the epidemic strain. A case-control study was conducted to identify possible sources of infection. In univariable analysis, cases were almost five times more likely to smoke than controls (odds ratio (OR): 4.81; 95% confidence interval (CI): 2.33-9.93; p < 0.0001). Furthermore, cases were twice as likely to live within a 3 km distance from one identified infection source as controls (OR: 2.14; 95% CI: 1.09-4.20; p < 0.027). This is the largest outbreak of LD in Germany to date. Due to a series of uncommon events, this outbreak was most likely caused by multiple sources involving industrial cooling towers. Quick epidemiological assessment, source tracing and shutting down of potential sources as well as rapid laboratory testing and early treatment are necessary to reduce morbidity and mortality. Maintenance of cooling towers must be carried out according to specification to prevent similar LD outbreaks in the future.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号