conformity index

合格指数
  • 文章类型: Clinical Trial, Phase II
    OBJECTIVE: To evaluate the variation in investigator-delineated volumes and assess plans from the radiotherapy trial quality assurance (RTTQA) program of SCALOP, a phase II trial in locally advanced pancreatic cancer.
    METHODS: Participating investigators (n=25) outlined a pre-trial benchmark case as per RT protocol, and the accuracy of investigators\' GTV (iGTV) and PTV (iPTV) was evaluated, against the trials team-defined gold standard GTV (gsGTV) and PTV (gsPTV), using both qualitative and geometric analyses. The median Jaccard Conformity Index (JCI) and Geographical Miss Index (GMI) were calculated. Participating RT centers also submitted a radiotherapy plan for this benchmark case, which was centrally reviewed against protocol-defined constraints.
    RESULTS: Twenty-five investigator-defined contours were evaluated. The median JCI and GMI of iGTVs were 0.57 (IQR: 0.51-0.65) and 0.26 (IQR: 0.15-0.40). For iPTVs, these were 0.75 (IQR: 0.71-0.79) and 0.14 (IQR: 0.11-0.22) respectively. Qualitative analysis showed largest variation at the tumor edges and failure to recognize a peri-pancreatic lymph node. There were no major protocol deviations in RT planning, but three minor PTV coverage deviations were identified. .
    CONCLUSIONS: SCALOP demonstrated considerable variation in iGTV delineation. RTTQA workshops and real-time central review of delineations are needed in future trials.
    导出

    更多引用

    收藏

    翻译标题摘要

    我要上传

    求助全文

公众号