关键词: Haptic curing IOL tilt Yamane technique

来  源:   DOI:10.1016/j.ajoc.2024.102049   PDF(Pubmed)

Abstract:
UNASSIGNED: To describe a case of intraocular lens (IOL) tilt following transscleral IOL fixation with the Yamane technique and subsequent correction of tilt using 810-nm endoscopic diode laser.
UNASSIGNED: Our patient required lens exchange and secondary IOL implantation due to a dislocated 1-piece IOL in the bag causing iris chafe. After routine IOL fixation with the Yamane technique and a Zeiss CT Lucia 602 lens, the IOL tilted significantly in the immediate postoperative period. The lens tilt was subsequently corrected in the operating room using endolaser to melt and reshape (cure) the optic-haptic junction.
UNASSIGNED: IOL tilt is a known complication associated with the Yamane technique, which has seen increasing reports with the Zeiss CT Lucia 602 lens. Using endolaser to reconfigure the tilted optic into the desired orientation is a more novel procedure that can correct the lens tilt without the need for IOL exchange.
摘要:
描述使用Yamane技术经巩膜IOL固定后人工晶状体(IOL)倾斜的情况,并随后使用810nm内窥镜二极管激光校正倾斜。
我们的患者需要更换晶状体和二次IOL植入,因为袋中的1片IOL脱位导致虹膜擦伤。在使用Yamane技术和ZeissCTLucia602透镜进行常规IOL固定后,术后即刻IOL明显倾斜。随后在手术室中使用内激光来熔化和重新成形(固化)光学-触觉接合处来校正透镜倾斜。
IOL倾斜是与Yamane技术相关的已知并发症,蔡司CT露西亚602镜头的报道越来越多。使用眼内激光将倾斜的光学器件重新配置到所需的取向是一种更新颖的程序,可以在不需要更换IOL的情况下校正透镜倾斜。