UNASSIGNED: A 41-year-old male patient with distant history of a right orbital floor fracture had undergone repair with the placement of a nylon foil implant. The patient presented twenty years later with progressive ipsilateral globe proptosis and was found to have a giant inferior orbital cyst. Surgical exploration and removal of the implant and capsule were performed. Histopathology confirmed a delayed foreign body reaction around the patient\'s alloplastic implant.
UNASSIGNED: Alloplastic implants may result foreign body reaction and cyst encapsulation as a delayed complication.
■一名41岁的男性患者,有右眶底骨折的遥远病史,接受了尼龙箔植入物的修复。20年后,该患者出现进行性同侧眼球突出,并被发现患有巨大的下眶囊肿。进行手术探查和移除植入物和囊。组织病理学证实患者的同种异体植入物周围有延迟的异物反应。
■同种异体植入物可能会导致异物反应和囊肿包裹,这是一种延迟性并发症。