关键词: Preset torque settings Root canal curvature location Scanning electron microscopy Screw-in force Torque

Mesh : Torque Humans Titanium / chemistry Nickel / chemistry Root Canal Preparation / instrumentation X-Ray Microtomography Surface Properties In Vitro Techniques Dental Pulp Cavity Molar Dental Instruments Materials Testing Equipment Design Dental Alloys / chemistry Dental Stress Analysis

来  源:   DOI:10.4012/dmj.2023-244

Abstract:
The aim of this study was to evaluate how preset torque settings influence the torque, vertical force, and root canal-centering ability of ProGlider and ProTaper NEXT nickel-titanium rotary instruments in canals with different curvature locations. Based on micro-computed tomography, mesial roots of human mandibular molars (25°-40° curvature) were allocated to the apical curvature (apical 1-5 mm) or the middle curvature (apical 5-9 mm) groups, and mandibular incisors (curvature <5°) to the straight canal group. Each group was subjected to automated instrumentation and torque/force measurement with the preset torque of 1, 2.5, or 5 N•cm. Canal-centering ratios were determined with micro-computed tomography. Instrument fracture occurred only in the 2.5 and 5 N•cm groups in curved canals. The preset torque setting and curvature location did not influence canal shaping ability.
摘要:
这项研究的目的是评估预设扭矩设置如何影响扭矩,垂直力,ProGlider和ProTaperNEXT镍钛旋转器械在不同曲率位置的根管对中能力。基于显微计算机断层扫描,人类下颌磨牙的中根(25°-40°曲率)被分配到根尖曲率(根尖1-5毫米)或中间曲率(根尖5-9毫米)组,和下颌切牙(曲率<5°)到直管组。对每组进行自动化仪器和扭矩/力测量,预设扭矩为1、2.5或5N·cm。用显微计算机断层扫描确定运河中心比率。器械骨折仅发生在弯曲管的2.5和5N•cm组中。预设的扭矩设置和曲率位置不会影响运河成形能力。