METHODS: We report the case of a 58-year-old woman who presented for knee surgery with soft tissue reconstruction, deformity correction with circular hexapod external fixation, and hinged TKA for a severe complex deformity and soft tissue injury caused by a burn injury at 6 months of age. The left leg was shorter by 35 mm in terms of functional leg length discrepancy. She walked with a limp, with a marked varus deformity of the left knee during the stance phase of walking. After a 3-stage repair, the patient was able to walk without assistance, confirming improvement of mobility.
CONCLUSIONS: The treatment method was an effective use of a combination of soft tissue reconstruction, circular hexapod external fixation, and rehearsal surgery using a 3D printed bone model of the modular rotating hinge component of TKA, which was successfully used to treat a severe knee dislocation due to burn scarring. This staged surgery maintained the leg length and ultimately achieved a satisfactory alignment.