关键词: Aortic L-Type Partial Replacement Reversed Sternotomy Valve

Mesh : Aortic Valve Stenosis / physiopathology surgery Female Heart Valve Prosthesis Implantation / methods Humans Length of Stay / statistics & numerical data Middle Aged Minimally Invasive Surgical Procedures / methods Sternotomy / methods Treatment Outcome

来  源:   DOI:10.5455/medarh.2016.70.229-231

Abstract:
BACKGROUND: Degenerative aortic stenosis (AS) is the most frequent cause among aortic valve stenotic changes. Mini Sternotomy Aortic Valve Replacement is a replacement of aortic valve through upper partial sternotomy.
OBJECTIVE: The aim of this approach is to improve postoperative convalescence by leaving pleural spaces closed and do not compromise respiratory function, to decrease bleeding, and reduce post op ventilation time and ICU stay. All these advantages decrease cost during hospital stay by reducing ICU stay, respiration time, bleeding and using blood products, pain killers and shortening hospital stay. Esthetic effect is also considerable result of this method.
METHODS: This case report presents an initial experience with Reversed L-Type Upper Partial Sternotomy in Aortic Valve Replacement. The goal is to demonstrate that minimally invasive advanced cardiac surgery procedures can be performed in our country.
摘要:
暂无翻译