{Reference Type}: Journal Article {Title}: Tele-Impedance control of a virtual avatar based on EMG and M-IMU sensors: a proof-of-concept. {Author}: Buscaglione S;Noccaro A;Tagliamonte N;Ticchiarelli G;Di Pino G;Formica D; {Journal}: Sci Rep {Volume}: 14 {Issue}: 1 {Year}: 2024 08 9 {Factor}: 4.996 {DOI}: 10.1038/s41598-024-68232-x {Abstract}: The broad spread of cooperative robots into many application domains has resulted in a demand for intuitive and effective solutions for teleoperated control. A relevant role in teleoperation has been assumed by impedance controllers, that allow the increase of stability and accuracy during interaction. This paper aims to test a teleoperation method based on an impedance controller, namely tele-impedance control, that is usable in unstructured environments since it relies only on wearable sensors. The proposed solution maps the joint stiffness and position of the human user, computed through six EMG and two M-IMU sensors, into the remote system to be teleoperated. We developed a 2-DoFs virtual task involving virtual physical interactions to compare the performance of our solution with the one of a traditional position-based controller. The study has been conducted on five healthy participants, who experienced both controllers in two different sessions. The tele-impedance approach has proved to be less physically demanding and more intuitive than the position-based one. Experimental data also allow us to investigate the strategy employed by the volunteers in the case of remote interactions, while using the two controllers. Of note, even though with the position controller the variation of subject impedance has no effect on the virtual arm, participants still tend to regulate both impedance and position of their own arm.