{Reference Type}: Journal Article {Title}: The influence of implant depth, abutment height and mucosal phenotype on peri‑implant bone levels: A 2-year clinical trial. {Author}: Quispe-López N;Guadilla Y;Gómez-Polo C;López-Valverde N;Flores-Fraile J;Montero J; {Journal}: J Dent {Volume}: 148 {Issue}: 0 {Year}: 2024 09 23 {Factor}: 4.991 {DOI}: 10.1016/j.jdent.2024.105264 {Abstract}: To evaluate the bone changes around equicrestal and subcrestal implants, analyzing the effect of abutment height [short abutments (SA < 2 mm) and long abutments (LA > 2 mm)] and the three components of the peri‑implant soft-tissue phenotype.
Twenty-six patients received 71 implants that were placed according to supracrestal tissue height (STH) in an equicrestal (n = 17), shallow subcrestal ≈1 mm (n = 33), or deep subcrestal ≈2 mm (n = 21) position. After 3 months of healing, rehabilitation was completed using metal-ceramic crowns on multi-unit abutments of 1.5 mm, 2.5 mm, or 3.5 mm in height, depending on the prosthetic space and STH. Longitudinal clinical parameters (STH, mucosal thickness, and keratinized mucosa width) and radiographic data [bone remodelling and marginal bone loss (MBL)] were collected at 3, 6, 12, and 24 months postsurgery.
The gain in STH was significantly greater around the implants placed in a subcrestal ≈2 mm position. After 2 years, the mean change in bone remodelling in the SA group was significantly greater than in the LA group. According to the multiple linear regression, bone remodelling depends primarily on abutment height (β = -0.43), followed by crestal position (β = 0.34), and keratinized mucosa width (β = -0.22), while MBL depends on abutment height (β = -0.37), and the patient's age (β = -0.36).
Implants placed in an equicrestal or subcrestal ≈1 mm position with LA undergo less bone remodelling, while the lowest level of MBL occurs in subcrestal ≈2 mm implants with LA. Differing soft-tissue thicknesses combined with the use of either SA or LA produced significant intergroup differences in bone remodelling and MBL.
Abutment height is the most powerful predictor variable affecting bone remodelling and MBL. Depending on the dimensions of the peri‑implant soft-tissue phenotype, placing the implants subcrestally may also be a viable option to decrease bone remodelling and, consequently, reduce MBL.
identification number: NCT05670340.