{Reference Type}: Journal Article {Title}: The first-in-human preclinical evaluation of the new probe [123I]I-PSMA-7 for real-time intraoperative targeted biopsy and SPECT/CT imaging in prostate cancer. {Author}: Luan X;Niu S;Liu Y;Zhang X;Xu X;Sun S;Sun Y;Zhang J;Wang Y;Chen Z;Chen Y;Cui M;Wang R;Zhang X;Zhang J;Xu B; {Journal}: Eur J Nucl Med Mol Imaging {Volume}: 0 {Issue}: 0 {Year}: 2024 Jul 23 {Factor}: 10.057 {DOI}: 10.1007/s00259-024-06833-4 {Abstract}: OBJECTIVE: PSMA/PET has been increasingly used to detect PCa, and PSMA/PET-guided biopsy has shown promising results. However, it cannot be confirmed immediately whether the tissues are the targeted area. In this study, we aimed to develop a novel probe, [123I]I-PSMA-7. First, we hope that [123I]I-PSMA-7 can provide instant confirmation for prostate biopsy. Second, we hope it will help detect PCa.
METHODS: We synthesized a high-affinity probe, [123I]I-PSMA-7, and evaluated its properties. We included ten patients with suspected PCa and divided them into two groups. The injection and biopsy were approximately 24 h apart. The activity in biopsy lesions was measured as the cpm by a γ-counter. Moreover, we enrolled 3 patients to evaluate the potential of [123I]I-PSMA-7 for detecting PCa.
RESULTS: Animal experiments verified the safety, targeting and effectiveness of [123I]I-PSMA-7, and the tumor-to-muscle ratio was greatest at 24 h, which confirmed the results of this study in humans. After injection of 185MBq [123I]I-PSMA-7, 18/55 cores were positive, and the cpm was significantly greater (4345 ± 3547 vs. 714 ± 547, P < 0.001), with an AUC of 0.97 and a cutoff of 1312 (sens/spec of 94.40%/91.90%). At a lower dose, 10/55 biopsy cores were cancerous, and the cpm was 2446 ± 1622 vs. 153 ± 112 (P < 0.001). The AUC was 1, with a cutoff value of 490 (sens/spec of 100%). When the radiopharmaceuticals were added to 370 MBq, we achieved better SPECT/CT imaging.
CONCLUSIONS: With the aid of [123I]I-PSMA-7 and via cpm-based biopsy, we can reduce the number of biopsies to a minimum operation. [123I]I-PSMA-7 PSMA SPECT/CT can also provide good imaging results.
BACKGROUND: Chinese Clinical trial registry ChiCTR2300069745, Registered 24 March 2023.