{Reference Type}: Case Reports {Title}: Implantable cardiac monitor and leadless pacemaker in the management of syncope due to intermittent high-degree atrioventricular block: a case report. {Author}: Tang N;Chen X;Zhang D;Li H; {Journal}: J Cardiothorac Surg {Volume}: 19 {Issue}: 1 {Year}: 2024 Jul 13 {Factor}: 1.522 {DOI}: 10.1186/s13019-024-02962-x {Abstract}: BACKGROUND: Lead dislodgements, tricuspid valve failure, and wound infections are prominent issues addressed by leadless pacemakers (LPM). These devises have emerged as viable alternatives to conventional transvenous pacemakers. LPMs offer minimized complications and effective pacing, particularly beneficial for elderly patients with a low body mass index (BMI) who are at heightened infection of risk. The Micra AV leadless pacemaker was released in the US in 2020, featuring a VDD pacing mode akin to conventional pacemakers. It senses atrial activity to pace ventricular beats while maintaining the natural atrioventricular activation sequence. Micra AV achieves atrioventricular synchronization through mechanical sensing principles. Ongoing research aims to assess its efficacy, implantation feasibility, and clinical safety.
METHODS: An 83-year-old man with a history of syncope was the focus of this case study. An implantable cardiac monitor (ICM) recorded occasional high-degree atrioventricular block in the patient. Subsequently, the Micra AV was implanted via the left femoral vein, and its settings were adjusted in accordance with data obtained from the ICM. No significant issues regarding pacing threshold or impedance were found during the follow-up examinations post-surgery. Importantly, the patient experienced a noticeable reduction in symptoms compared to before the implantation.
CONCLUSIONS: This case underscores the significance of ICM monitoring in elucidating cardiac events leading to syncope and guiding appropriate treatment. It also highlights the successful outcomes and reliable implantation of the Micra AV for managing high-degree atrioventricular block. This study contributes to the growing body of evidence supporting the adoption of leadless pacemakers as a viable option for patients requiring cardiac pacing, particularly those vulnerable to complications associated with traditional pacemakers. It provides real-world evidence of Micra AV's efficacy and safety, further validating its role in clinical practice.