{Reference Type}: Journal Article {Title}: Quality of different obturation techniques to fill perforating internal root resorption: a micro-computed tomographic study. {Author}: Sadat SMAE;Chew HP;Fok A;Elashiry MM;ElShenawy AM;Saber S; {Journal}: BMC Oral Health {Volume}: 24 {Issue}: 1 {Year}: 2024 Jul 13 {Factor}: 3.747 {DOI}: 10.1186/s12903-024-04518-w {Abstract}: BACKGROUND: This study aimed to assess the quality of various obturation techniques to fill perforation caused by internal root resorption using Micro-computed Tomography.
METHODS: Cone-beam computed tomography images of a maxillary central incisor tooth with perforating internal resorptive defect were used to create a 3D printed model of the affected tooth. The replicas were divided into four groups based on the obturation technique used. The techniques included Group 1: a polydimethylsiloxane-based sealer (GuttaFlow-2) with gutta-percha. Group 2: same as Group 1 except for using a pre-mixed Bioceramic-based sealer (NeoSEALER Flo). Group 3: the defect was filled entirely using the NeoSealer Flo Bioceramic-based sealer. Group 4: the samples were obturated using the warm vertical compaction technique with a resin-based sealer (ADSeal). The resin models were then scanned a micro-computed scanner to evaluate the percentage of voids in each group.
RESULTS: The results showed that NeoSEALER Flo groups had significantly the highest volume of voids while GuttaFlow-2 and warm vertical compaction groups had the lowest void volume.
CONCLUSIONS: GuttaFlow-2 and warm vertical compaction techniques performed best in filling the internal resorptive defect.