{Reference Type}: Journal Article {Title}: Electrochemical dissolution and retrieval of broken NiTi endodontic files from root canal using chloride based isotonic fluids as electrolytes - An in vitro study. {Author}: Hariprasad R;Joy B;Kuriakose F;Sudhakar AS;Soumya TS;Pathrose SP; {Journal}: J Pharm Bioallied Sci {Volume}: 16 {Issue}: 0 {Year}: 2024 Apr 暂无{DOI}: 10.4103/jpbs.jpbs_1225_23 {Abstract}: UNASSIGNED: The electrochemical dissolution method of instrument retrieval emphasizes on the dissolution of the instrument rather than sacrificing dentine. Most of the studies conducted for electrochemical dissolution used fluoride-containing electrolytes and were performed inside a beaker. In this study, we used chloride-based fluids as electrolytes.
UNASSIGNED: Fifty extracted mandibular first premolars were divided into five groups based on the electrolytes used. Canals were enlarged to ProTaper Universal F2, and files were intentionally broken inside the canal. These specimens were subjected to electrochemical characterization by applying the potential of 9V for 20 min. Optical images were taken to assess the change in surface topography. The results were analyzed statistically by one-way analysis of variance (analysis of variance [ANOVA]).
UNASSIGNED: The rate of dissolution based on the electrolyte used decreased in the following order, viz. Tyrode's solution>artificial saliva>normal saline>Ringer's lactate/physiological serum.
UNASSIGNED: Apart from fluoride, chloride-based electrolytes could be an efficient alternative.