{Reference Type}: Case Reports {Title}: A case report of a distal radius fracture treated with a dorsal spanning plate augmented with fragment specific fixation. {Author}: Chen AL;Hernandez EJ;MacKay BJ; {Journal}: J Surg Case Rep {Volume}: 2024 {Issue}: 4 {Year}: 2024 Apr 暂无{DOI}: 10.1093/jscr/rjae260 {Abstract}: Dorsal spanning plates are frequently utilized to manage comminuted intra-articular distal radius fractures, but there is little literature on combining them with augmented fixation in complex cases. We present a 43-year-old man who fell 5 ft onto his outstretched right hand. On examination, there was gross swelling and tenderness of the right wrist with no neurovascular deficit. Radiographs confirmed a comminuted intra-articular displaced distal radius fracture. He was treated with a dorsal spanning plate fixation combined with radiostyloid and volar buttress plates. Follow-up at 2 months showcased intact hardware with good fracture healing. The dorsal spanning plate was removed 4 months after the procedure with radiographs demonstrating adequate alignment and healing without failure. The patient reported no complaints and minimal functional disability. We highlight a case of augmenting a dorsal spanning plate with fragment-specific plate fixation for a comminuted intra-articular displaced distal radius fracture.