{Reference Type}: Case Reports {Title}: Iatrogenic vertebral artery injury during catheter ablation treated using coil embolization. {Author}: Oshima T;Yamagata K;Shimizu Y;Koizumi S;Fujiu K;Komuro I; {Journal}: Pacing Clin Electrophysiol {Volume}: 0 {Issue}: 0 {Year}: 2024 Mar 25 {Factor}: 1.912 {DOI}: 10.1111/pace.14970 {Abstract}: The internal jugular vein (IJV) is occasionally used for blood access during catheter ablation. Additionally, accidental injury of the vertebral artery during an IJV puncture is a rare complication that can result in catastrophic events, such as death. However, vascular access complications cannot be completely prevented despite the introduction of ultrasound-guided punctures. Here, we present a case of a patient with symptomatic paroxysmal atrial fibrillation that required catheter ablation.