{Reference Type}: Journal Article {Title}: Adaptive ultra-hypofractionated whole-pelvic radiotherapy in high-risk and very high-risk prostate cancer on 1.5-Tesla MR-Linac: Estimated delivered dose and early toxicity results. {Author}: Gao L;Wei R;Qin S;Tian Y;Xia W;Song Y;Wang S;Fang H;Tang Y;Jing H;Liu Y;Tang Y;Qi S;Chen B;Li Y;Xing N;Lu N; {Journal}: Chronic Dis Transl Med {Volume}: 10 {Issue}: 1 {Year}: 2024 Mar 暂无{DOI}: 10.1002/cdt3.114 {Abstract}: UNASSIGNED: Magnetic resonance (MR)-guided ultra-hypofractionated radiotherapy with whole-pelvic irradiation (UHF-WPRT) is a novel approach to radiotherapy for patients with high-risk (HR) and very high-risk (VHR) prostate cancer (PCa). However, the inherent complexity of adaptive UHF-WPRT might inevitably result in longer on-couch time. We aimed to estimate the delivered dose, study the feasibility and safety of adaptive UHF-WPRT on a 1.5-Tesla MR-Linac.
UNASSIGNED: Ten patients with clinical stage T3a-4N0-1M0-1c PCa, who consecutively received UHF-WPRT, were enrolled prospectively. The contours of the target and organ-at-risks on the position verification-MR (PV-MR), beam-on 3D-MR(Bn-MR), and post-MR (after radiotherapy delivery) were derived from the pre-MR data by deformable image registration. The physician then manually adjusted them, and dose recalculation was performed accordingly. GraphPad Prism 9 (GraphPad Prism Software Inc.) was utilized for conducting statistical analyses.
UNASSIGNED: In total, we collected 188 MR scans (50 pre-MR, 50 PV-MR, 44 Bn-MR, and 44 post-MR scans). With median 59 min, the mean prostate clinical target volume (CTV)-V100% was 98.59% ± 2.74%, and the mean pelvic CTVp-V100% relative percentages of all scans was 99.60% ± 1.18%. The median V29 Gy change in the rectal wall was -2% (-18% to 20%). With a median follow-up of 9 months, no patient had acute Common Terminology Criteria for Adverse Events (CTCAE) grade 2 or more severe genitourinary (GU) or gastrointestinal (GI) toxicities (0%).
UNASSIGNED: UHF-RT to the prostate and the whole pelvis with concomitant boost to positive nodes using an Adapt-To-Shape (ATS) workflow was technically feasible for patients with HR and VHR PCa, presenting only mild GU and GI toxicities. The estimated target dose during the beam-on phase was clinically acceptable based on the 3D-MR-based dosimetry analysis.
UNASSIGNED: Chinese Clinical Trial Registry ChiCTR2000033382.