{Reference Type}: Journal Article {Title}: Mathematical modelling and comparative analysis of treatment technologies for upgrading wastewater treatment plants: A case study of biofilm reactors in El-Gouna, Egypt. {Author}: Osama A;Kinnawy MA;Moussa MS;Riechelmann C;Hosney H; {Journal}: Environ Res {Volume}: 238 {Issue}: 0 {Year}: 2023 12 1 {Factor}: 8.431 {DOI}: 10.1016/j.envres.2023.117008 {Abstract}: In recent years, Moving Bed Biofilm Reactors (MBBRs) have been preferred to conventional processes with suspended biomass. The main reason for this preference is that it can achieve better removal efficiencies than conventional systems with smaller footprints. However, unlocking the full potential of MBBRs in large-scale WWTPs remains challenging in real life. In this study, the performance of three different treatment technologies, Extended Aeration Activated Sludge (EAAS), Hybrid Fixed Bed Biofilm Reactor (HFBBR), and Hybrid Moving Bed Biofilm Reactor (HMBBR), was investigated over a year in a WWTP located in El-Gouna, Egypt. The COD removal efficiencies of the three systems were comparable, with the EAAS achieving 93.5%, HFBBR 94%, and HMBRR 95%. Nevertheless, the NH4 removal efficiency of the EAAS was slightly lower (97.5%) than that of the HFBBR and the HMBBR, that achieved a removal efficiency of 98%. BioWin Software was able to mimic the real case of the WWTP of El-Gouna and critically defined all plant limitations and operational data. Different simulations were modeled to test the hydraulic and organic loading capacities of the three systems under different scenarios and operating conditions. The HMBBR system failed to withstand the increase in organic load because of the biomass sloughing effect and subsequently high TSS loads in the settlers. Biomass sloughing overloaded the settlers and lead to biomass loss in the effluent. As the settleability of the HMBBR sludge was significantly lower than for the HFBBR the TSS loss in the effluent happened that much earlier that the moving carrier application had an adverse effect contradicting with the primary purpose of adding media carriers. Model simulations and data analysis findings were used to recommend the most suitable configuration for upgrading an existing system using the attached growth technique with all kinetic parameters and operational conditions. The recommended configuration focuses mainly on the separation of plastic media in a compartment with a very low hydraulic retention time to absorb the incoming shock load.