{Reference Type}: Journal Article {Title}: Comparison of MiraLAX and magnesium citrate for bowel preparation at CT colonography. {Author}: Zacharias N;Lubner MG;Kim DH;Pickhardt PJ; {Journal}: Abdom Radiol (NY) {Volume}: 48 {Issue}: 11 {Year}: 2023 Nov 29 暂无{DOI}: 10.1007/s00261-023-04025-6 {Abstract}: OBJECTIVE: To compare MiraLAX, a hypo-osmotic lavage, and magnesium citrate (MgC), a hyper-osmotic agent for bowel preparation at CTC.
METHODS: 398 total screening CTC studies were included in this retrospective, single institution study. 297 underwent preparation with a double-dose MgC regimen (mean age, 61 ± 5.5 years; 142 male/155 female) and 101 with 8.3 oz (equivalent to 238 g PEG) of MiraLAX (mean age, 60 ± 9.6 years; 45 male/56 female). Oral contrast for tagging purposes was utilized in both regimens. Studies were retrospectively analyzed for residual fluid volume and attenuation by automated analysis, as well for subjective oral contrast coating of the normal colonic wall and polyps. 50 patients underwent successive CTC studies utilizing each agent (mean, 6.1 ± 1.7 years apart), allowing for intra-patient comparison. Chi-squared, Fisher's exact, McNemar, and t-tests were used for data comparison.
RESULTS: Residual fluid volume (as percentage of total colonic volume) and fluid density was 7.2 ± 4.2% and 713 ± 183 HU for the MgC cohort and 8.7 ± 3.8% and 1044 HU ± 274 for the MiraLAX cohort, respectively (p = 0.001 and p < 0.001, respectively). Similar results were observed for the intra-patient cohort. Colonic wall coating negatively influencing interpretation was noted in 1.7% of MgC vs. 6.9% of MiraLAX examinations (p = 0.008). Polyps were detected in 12% of all MgC vs. 16% of all MiraLAX CTCs (p = 0.29).
CONCLUSIONS: CTC bowel preparation with the hypo-osmotic MiraLAX agent appears to provide acceptable diagnostic quality that is comparable to the hyper-osmotic MgC agent, especially when factoring in patient safety and tolerance.