{Reference Type}: Journal Article {Title}: Steady-State Piperacillin Concentrations in the Proximity of an Orthopedic Implant: A Microdialysis Porcine Study. {Author}: Lilleøre JG;Jørgensen AR;Knudsen MB;Hanberg P;Öbrink-Hansen K;Tøstesen SK;Søballe K;Stilling M;Bue M; {Journal}: Antibiotics (Basel) {Volume}: 12 {Issue}: 3 {Year}: Mar 2023 20 {Factor}: 5.222 {DOI}: 10.3390/antibiotics12030615 {Abstract}: Implant-associated osteomyelitis is one of the most feared complications following orthopedic surgery. Although the risk is low, sufficient antibiotic protection of the implant surface is important. The aim of this study was to assess steady-state piperacillin concentrations in the proximity of an orthopedic implant. Time above the minimal inhibitory concentration (fT>MIC) was evaluated for MIC of 8 (low target) and 16 μg/mL (high target). Six female pigs received an intravenous bolus infusion of 4 g/0.5 g piperacillin/tazobactam over 30 min every 6 h. Steady state was assumed achieved in the third dosing interval (12-18 h). Microdialysis catheters were placed in a cannulated screw in the proximal tibial cancellous bone, in cancellous bone next to the screw, and in cancellous bone on the contralateral tibia. Dialysates were collected from time 12 to 18 h and plasma samples were collected as reference. For the low piperacillin target (8 µg/mL), comparable mean fT>MIC across all the investigated compartments (mean range: 54-74%) was found. For the high target (16 µg/mL), fT>MIC was shorter inside the cannulated screw (mean: 16%) than in the cancellous bone next to the screw and plasma (mean range: 49-54%), and similar between the two cancellous bone compartments. To reach more aggressive piperacillin fT>MIC targets in relation to the implant, alternative dosing regimens such as continuous infusion may be considered.