{Reference Type}: Journal Article {Title}: No difference in range of motion in reverse total shoulder arthroplasty using standard or constrained liners: a matched cohort study. {Author}: Goodloe JB;Denard PJ;Lederman E;Gobezie R;Werner BC; {Journal}: JSES Int {Volume}: 6 {Issue}: 6 {Year}: Nov 2022 暂无{DOI}: 10.1016/j.jseint.2022.07.004 {Abstract}: UNASSIGNED: Prosthetic instability is one of the most common short-term complications following reverse total shoulder arthroplasty (RTSA). Numerous strategies exist to attempt to mitigate this complication, including utilization of constrained polyethylene humeral liners. A concern of constrained humeral liners is that they may come at the expense of restricted rotational range of motion (ROM). The purpose of the present study is to compare range of ROM and patient-reported outcomes (PROs), and satisfaction among matched cohorts using constrained vs. unconstrained liners after RTSA.
UNASSIGNED: A multicenter shoulder arthroplasty registry was retrospectively reviewed to identify patients with two-year clinical follow-up after RTSA with constrained liners used at the surgeon's discretion. All patients had the same inlay humeral prosthesis with a 135° neck shaft angle. This study cohort was matched 1:2 to control patients who underwent RTSA with standard liners based on age, sex, total glenoid-sided lateralization, glenosphere diameter, and surgery performed on the dominant arm. Improvement in PROs and ROM was compared between groups.
UNASSIGNED: Twenty-two patients were identified who underwent RTSA with a constrained humeral liner; these were compared to 44 matched patients with standard liners. The groups were found to have no notable differences in demographics, baseline PROs and ROM. At two years postoperatively, both cohorts demonstrated improvements in all PROs without statistically significant differences between the two groups. There were no differences between groups in improvement in any ROM measure, including forward flexion (constrained: 54°, standard: 57°, P = .771), external rotation at the side (constrained: 42°, standard: 41°, P = .906) or internal rotation at 90° of abduction (constrained: 24°, standard: 20°, P = .587).
UNASSIGNED: For an inlay humeral prosthesis with a 135° neck shaft angle, utilization of a constrained liner for RTSA demonstrates no significant difference in ROM or PROs compared to a well-matched cohort of patients who underwent RTSA with a standard polyethylene humeral liner. These are reassuring data for using constrained liners when there is intraoperative concern for prosthetic instability.