{Reference Type}: Journal Article {Title}: International Nosocomial Infection Control Consortium (INICC) report, data summary of 45 countries for 2012-2017: Device-associated module. {Author}: Rosenthal VD;Bat-Erdene I;Gupta D;Belkebir S;Rajhans P;Zand F;Myatra SN;Afeef M;Tanzi VL;Muralidharan S;Gurskis V;Al-Abdely HM;El-Kholy A;AlKhawaja SAA;Sen S;Mehta Y;Rai V;Hung NV;Sayed AF;Guerrero-Toapanta FM;Elahi N;Morfin-Otero MDR;Somabutr S;De-Carvalho BM;Magdarao MS;Velinova VA;Quesada-Mora AM;Anguseva T;Ikram A;Aguilar-de-Moros D;Duszynska W;Mejia N;Horhat FG;Belskiy V;Mioljevic V;Di-Silvestre G;Furova K;Gamar-Elanbya MO;Gupta U;Abidi K;Raka L;Guo X;Luque-Torres MT;Jayatilleke K;Ben-Jaballah N;Gikas A;Sandoval-Castillo HR;Trotter A;Valderrama-Beltrán SL;Leblebicioglu H; ; {Journal}: Am J Infect Control {Volume}: 48 {Issue}: 4 {Year}: 04 2020 {Factor}: 4.303 {DOI}: 10.1016/j.ajic.2019.08.023 {Abstract}: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2012 to December 2017 in 523 intensive care units (ICUs) in 45 countries from Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific.
During the 6-year study period, prospective data from 532,483 ICU patients hospitalized in 242 hospitals, for an aggregate of 2,197,304 patient days, were collected through the INICC Surveillance Online System (ISOS). The Centers for Disease Control and Prevention-National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI) were applied.
Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the medical-surgical ICUs, the pooled central line-associated bloodstream infection rate was higher (5.05 vs 0.8 per 1,000 central line-days); the ventilator-associated pneumonia rate was also higher (14.1 vs 0.9 per 1,000 ventilator-days,), as well as the rate of catheter-associated urinary tract infection (5.1 vs 1.7 per 1,000 catheter-days). From blood cultures samples, frequencies of resistance, such as of Pseudomonas aeruginosa to piperacillin-tazobactam (33.0% vs 18.3%), were also higher.
Despite a significant trend toward the reduction in INICC ICUs, DA-HAI rates are still much higher compared with CDC-NHSN's ICUs representing the developed world. It is INICC's main goal to provide basic and cost-effective resources, through the INICC Surveillance Online System to tackle the burden of DA-HAIs effectively.