%0 Journal Article %T Comparison of Outcomes with the Use of Different Heat-Activated Crimping Prostheses in Stapedotomy. %A Ni G %A Monos S %A Kortebein S %A Symms J %A Ettyreddy A %A Hillman TA %A Chen DA %J Otol Neurotol %V 45 %N 8 %D 2024 Sep 1 %M 39142311 %F 2.619 %R 10.1097/MAO.0000000000004276 %X OBJECTIVE: To determine differences in failure rate and hearing outcomes of a completely encircling heat-activated crimping prosthesis (SMart 360°) compared to partially encircling prosthesis (SMart).
METHODS: Retrospective chart review.
METHODS: Private neurotology tertiary referral center.
METHODS: Patients who underwent stapedotomies performed by the senior authors from 2008 to 2019 using the SMart prosthesis and SMart 360° prothesis.
METHODS: Stapedotomy operations with placement of a SMart or SMart 360° prosthesis.
METHODS: Incidence of early failure requiring revision surgery. Differences in preoperative air-bone gap (ABG) compared to postoperative ABG at 3 months, 1 year, and 2 years after surgery.
RESULTS: A total of 228 stapedotomies were performed (SMart n = 48 and SMart 360° n = 180). Mean preoperative ABG for SMart and SMart 360° were 26.15 and 29 dB, respectively. The mean difference in ABG for the SMart at 3 months, 1 year, and 2 years were 17, 18, and 11 dB, respectively. The mean difference in ABG for the SMart 360° at 3 months, 1 year, and 2 years were 20, 20, and 19 dB. ABG differences at 3 months (p = 0.10) and 1 year (p = 0.36) were not statistically different. The failure rate for the SMart prosthesis was 12.5% and for the SMart 360° 2.2% (p = 0.002).
CONCLUSIONS: There were no statistically significant differences in ABG changes for SMart compared to SMart 360°. The Smart 360 corrects the problem with early failure seen with the Smart prosthesis.
UNASSIGNED: Determination of most efficacious stapes prosthesis.
OBJECTIVE: Which stapes prosthesis produces better hearing results with fewer failures.
UNASSIGNED: To disseminate information necessary to choose the best stapes prosthesis for patients.
METHODS: Level III.
UNASSIGNED: 2022-029-agh.